Abstract
In this paper, a flexible voltage control strategy, which takes good use of the distributed energy storage (DES) units, is proposed to enhance the voltage stability and robustness of dc distribution network. The characteristics of ac/dc interface in network are analyzed, and the virtual inertia and capacitance are given to demonstrate the interactive influence of the ac and the dc systems. The control strategy for DES which is located at the ac microgrid or at the network terminal bus is designed based on the interactive characteristics, enabling the DES to respond to both voltage variation of dc network and frequency change of utility ac grid. A cascading droop control strategy is proposed for DES in dc microgrid to relieve the pressure of voltage deterioration of dc network buses which connect the dc microgrid. The proposed comprehensive flexible control strategy for DESs at different interfaces features independence of communication as well as enhancement of system robustness, and reduces the impact of dc distribution network on utility ac grid. The performance of the proposed control strategy is validated under different operating conditions of the dc distribution network.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Guerrero, J. M., Vasquez, J. C., Matas, J., de Vicuna, L. G., & Castilla, M. (2011) · IEEE Transactions on Industrial Electronics · doi:10.1109/tie.2010.2066534 · Cited by 5,075 · cited 1×
“is proposed in [15] and [16], which assigns different control aims into several levels to regulate more involving elements and mitigate the influence of droop control.”
BackgroundAC-microgrids versus DC-microgrids with distributed energy resources: A review
Justo, J. J., Mwasilu, F., Lee, J., & Jung, J.-W. (2013) · Renewable and Sustainable Energy Reviews · doi:10.1016/j.rser.2013.03.067 · Cited by 1,245 · cited 1×
“Similar to the AC distribution network, the DC network can be classified into three typical types: 1) the radial structure; 2) the ring structure; and 3) the dual or the multi-terminal structure [26].”
BackgroundLow-Voltage Bipolar-Type DC Microgrid for Super High Quality Distribution
Kakigano, H., Miura, Y., & Ise, T. (2010) · IEEE Transactions on Power Electronics · doi:10.1109/tpel.2010.2077682 · Cited by 995 · cited 1×
“voltage microgrid [1]–[3].”
Overview of Power Management Strategies of Hybrid AC/DC Microgrid
Nejabatkhah, F., & Li, Y. W. (2015) · IEEE Transactions on Power Electronics · doi:10.1109/tpel.2014.2384999 · Cited by 986 · cited 1×
“It should be noted that when some severe power events occur and the power quality cannot be guaranteed, which means the above delta values are beyond their limits, the common emergency measures like load shedding or microgrid disconnection will be activated to keep the stability of the DC distribution system [28].”
BackgroundSelf-citationHVDC Connection of Offshore Wind Farms to the Transmission System
Bresesti, P., Kling, W. L., Hendriks, R. L., & Vailati, R. (2007) · IEEE Transactions on Energy Conversion · doi:10.1109/tec.2006.889624 · Cited by 750 · cited 1×
“voltage microgrid [1]–[3].”
Control of Distributed Uninterruptible Power Supply Systems
Guerrero, J. M., Hang, L., & Uceda, J. (2008) · IEEE Transactions on Industrial Electronics · doi:10.1109/tie.2008.924173 · Cited by 700 · cited 1×
“Droop control strategy is free of communication and uses the voltage signal to regulate the output power of controlled converters [12]–[16].”
BackgroundLow-Voltage DC Distribution System for Commercial Power Systems With Sensitive Electronic Loads
Salomonsson, D., & Sannino, A. (2007) · IEEE Transactions on Power Delivery · doi:10.1109/tpwrd.2006.883024 · Cited by 561 · cited 1×
“, photovoltaic (PV) systems, batteries, super capacitors; 2) improving power efficiency significantly by reducing the AC/DC conversion stages [4], [5]; 3) larger power transmission capacity available and problems such as synchronization stability, reactive power control and harmonics can be avoided [6], [7].”
BackgroundAugustine, S., Mishra, M. K., & Lakshminarasamma, N. (2015) · IEEE Transactions on Sustainable Energy · doi:10.1109/tste.2014.2360628 · Cited by 490 · cited 1×
“To address the voltage mismatch, an adaptive droop control method is investigated [14], which is able to minimize the voltage drop and load current sharing difference by introducing a figure of merit index.”
MethodInertia Emulation Control Strategy for VSC-HVDC Transmission Systems
Zhu, J., Booth, C. D., Adam, G. P., Roscoe, A. J., & Bright, C. G. (2013) · IEEE Transactions on Power Systems · doi:10.1109/tpwrs.2012.2213101 · Cited by 466 · cited 1×
“IC can be treated as a virtual synchronous machine seen from AC side, providing the frequency support [29]; similarly, when the power is absorbed from AC grid to DC grid, the IC can”
BackgroundPower Smoothing of Large Solar PV Plant Using Hybrid Energy Storage
Wang, G., Ciobotaru, M., & Agelidis, V. G. (2014) · IEEE Transactions on Sustainable Energy · doi:10.1109/tste.2014.2305433 · Cited by 298 · cited 1×
“, easy to be installed, fast response rate [19], [20].”
BackgroundEdison Redux: 380 Vdc Brings Reliability and Efficiency to Sustainable Data Centers
AlLee, G., & Tschudi, W. (2012) · IEEE Power and Energy Magazine · doi:10.1109/mpe.2012.2212607 · Cited by 273 · cited 1×
“, large-scale data centers, shipboard systems [8], [9], medium voltage DC (MVDC) distribution network is getting more attraction in the future smart grid architecture.”
BackgroundIntelligent DC Microgrid With Smart Grid Communications: Control Strategy Consideration and Design
Wang, B., Sechilariu, M., & Locment, F. (2012) · IEEE Transactions on Smart Grid · doi:10.1109/tsg.2012.2217764 · Cited by 257 · cited 4×
“In [21], the ES unit is activated only in the state when the microgrid is isolated from the utility grid or there is a limitation for utility grid output, which makes the ES unit of high”
BackgroundInfluentialMultilevel Energy Management System for Hybridization of Energy Storages in DC Microgrids
Xiao, J., Wang, P., & Setyawan, L. (2015) · IEEE Transactions on Smart Grid · doi:10.1109/tsg.2015.2424983 · Cited by 160 · cited 3×
“is proposed in [15] and [16], which assigns different control aims into several levels to regulate more involving elements and mitigate the influence of droop control.”
BackgroundMethodThe Load as an Energy Asset in a Distributed DC SmartGrid Architecture
Balog, R. S., Weaver, W. W., & Krein, P. T. (2011) · IEEE Transactions on Smart Grid · doi:10.1109/tsg.2011.2167722 · Cited by 154 · cited 1×
“, photovoltaic (PV) systems, batteries, super capacitors; 2) improving power efficiency significantly by reducing the AC/DC conversion stages [4], [5]; 3) larger power transmission capacity available and problems such as synchronization stability, reactive power control and harmonics can be avoided [6], [7].”
BackgroundLi, C., Bosio, F., Fang, C., Chaudhary, S. K., Vásquez, J. C., & Guerrero, J. M. (2016) · IEEE Journal of Emerging and Selected Topics in Power Electronics · doi:10.1109/jestpe.2016.2634026 · Cited by 143 · cited 1×
“In [24], the economic dis-”
Self-citationIntegrated SMES Technology for Modern Power System and Future Smart Grid
Chen, X., Jin, J. X., Xin, Y., Shu, B., Tang, C. L., Zhu, Y. P., & Sun, R. M. (2014) · IEEE Transactions on Applied Superconductivity · doi:10.1109/tasc.2014.2346502 · Cited by 95 · cited 1×
“, easy to be installed, fast response rate [19], [20].”
BackgroundReal-Time Operation and Harmonic Analysis of Isolated and Non-Isolated Hybrid DC Microgrid
Farhadi, M., & Mohammed, O. A. (2014) · IEEE Transactions on Industry Applications · doi:10.1109/tia.2014.2298556 · Cited by 80
Cost Reduction of a Hybrid Energy Storage System Considering Correlation Between Wind and PV Power
Feng, L., Zhang, J.-N., Li, G., & Zhang, B. (2016) · Protection and Control of Modern Power Systems · doi:10.1186/s41601-016-0021-1 · Cited by 72 · cited 1×
“To compensate the mismatch of the distributed sources generation and the local loads consumption ES technique is generally utilized [17], [18].”
MethodTowards Building an Optimal Demand Response Framework for DC Distribution Networks
Mohsenian‐Rad, H., & Davoudi, A. A. (2014) · IEEE Transactions on Smart Grid · doi:10.1109/tsg.2014.2308514 · Cited by 70 · cited 2×
“load side, the concept of demand side response (DSR) has been proposed [23]–[25].”
BackgroundDynamic Behavior of Multiport Power Electronic Interface Under Source/Load Disturbances
Shamsi, P., & Fahimi, B. (2012) · IEEE Transactions on Industrial Electronics · doi:10.1109/tie.2012.2210376 · Cited by 67 · cited 1×
“, photovoltaic (PV) systems, batteries, super capacitors; 2) improving power efficiency significantly by reducing the AC/DC conversion stages [4], [5]; 3) larger power transmission capacity available and problems such as synchronization stability, reactive power control and harmonics can be avoided [6], [7].”
BackgroundDecentralized Primary Control of MTDC Networks With Energy Storage and Distributed Generation
Gavriluţă, C., Candela, J. I., Citro, C., Rocabert, J., Luna, Á., & Rodríguez, P. (2014) · IEEE Transactions on Industry Applications · doi:10.1109/tia.2014.2315715 · Cited by 66 · cited 1×
“system [27].”
Control principles of micro-source inverters used in microgrid
Guo, W., & Mu, L. (2016) · Protection and Control of Modern Power Systems · doi:10.1186/s41601-016-0019-8 · Cited by 55
Degree of Influence of System States Transition on the Stability of a DC Microgrid
Sánchez, S., & Molinas, M. (2014) · IEEE Transactions on Smart Grid · doi:10.1109/tsg.2014.2310901 · Cited by 50 · cited 1×
“, photovoltaic (PV) systems, batteries, super capacitors; 2) improving power efficiency significantly by reducing the AC/DC conversion stages [4], [5]; 3) larger power transmission capacity available and problems such as synchronization stability, reactive power control and harmonics can be avoided [6], [7].”
BackgroundNew Problem Formulation for Optimal Demand Side Response in Hybrid AC/DC Systems
Zhao, C., Dong, S., Gu, C., Li, F., Song, Y., & Padhy, N. P. (2016) · IEEE Transactions on Smart Grid · doi:10.1109/tsg.2016.2628040 · Cited by 25
Metadata
- Authors
- Li, Y., He, L., Liu, F., Li, C., Cao, Y., & Shahidehpour, M.
- Venue
- IEEE Transactions on Smart Grid
- Published
- 2019-01
- Volume
- 10
- Issue
- 1
- Pages
- 163-172
- ISSN
- 1949-3053 (ISSN-L)
- 1949-3061
- OpenAlex
- W2740382538
- Cited by
- 176
- References
- 24
- FWCI
- 12.57
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.