Diagonal Quadratic Approximation for Decentralized Collaborative TSO+DSO Optimal Power Flow
Open accessThe DOI matches its Crossref record; 28 of the 28 references it cites were found in a registry or an index.
Abstract
Collaborative operation of electricity transmission and distribution systems improves the economy and reliability of the entire power system. However, this is a challenging problem given that transmission system operators (TSOs) and distribution system operators (DSOs) are autonomous entities that are unwilling to reveal their commercially sensitive information. This paper presents a decentralized decision-making algorithm for collaborative TSO+DSO optimal power flow (OPF) implementation. The proposed algorithm is based on analytical target cascading for multilevel hierarchical optimization in complex engineering systems. A local OPF is formulated for each TSO/DSO taking into consideration interactions between the transmission and distribution systems while respecting autonomy and information privacy of TSO and DSOs. The local OPF of TSO is solved in the upper-level of hierarchy, and the local OPFs of DSOs are handled in the lower-level. A diagonal quadratic approximation (DQA) and a truncated DQA are presented to develop iterative coordination strategies in which all local OPFs are solved in a parallel manner with no need for a central coordinator. This parallel implementation significantly enhances computations efficiency of the algorithm. The proposed collaborative TSO+DSO OPF is evaluated using a 6-bus and the IEEE 118-bus test systems, and promising results are obtained.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Boyd, S., Parikh, N., Chu, E., Peleato, B., & Eckstein, J. (2011) · Foundations and Trends® in Machine Learning · doi:10.1561/2200000016 · Cited by 17,075
Boyd, S. (2010) · now publishers, Inc. eBooks · doi:10.1561/9781601984616 · Cited by 12,677
Parlar, M. (2000) · Interactive Operations Research with Maple · doi:10.1007/978-1-4612-1356-7_5 · Cited by 1,741
A Survey of Distributed Optimization and Control Algorithms for Electric Power Systems
Molzahn, D. K., Dorfler, F., Sandberg, H., Low, S. H., Chakrabarti, S., Baldick, R., & Lavaei, J. (2017) · IEEE Transactions on Smart Grid · doi:10.1109/tsg.2017.2720471 · Cited by 1,273 · cited 1×
“Iterative approached have been presented in [9]–[19] to solve OPF in a distributed fashion.”
Microgrids and Active Distribution Networks
Chowdhury, S., Chowdhury, S., & Crossley, P. A. (2009) · Institution of Engineering and Technology eBooks · doi:10.1049/pbrn006e · Cited by 1,198 · cited 1×
“security [1], [2].”
Zero Duality Gap in Optimal Power Flow Problem
Lavaei, J., & Low, S. H. (2012) · IEEE Transactions on Power Systems · doi:10.1109/tpwrs.2011.2160974 · Cited by 1,195 · cited 1×
“Also, the user may convexify ACOPF using techniques such as semidefinite programing or second order cone programing [42], [43].”
MethodDynamic Programming and Suboptimal Control: A Survey from ADP to MPC*
Bertsekas, D. P. (2005) · European Journal of Control · doi:10.3166/ejc.11.310-334 · Cited by 366 · cited 1×
“The convergence of the algorithm is guaranteed in [35] and [37].”
BackgroundTosserams, S., Etman, L. F. P., Papalambros, P. Y., & Rooda, J. E. (2006) · Structural and Multidisciplinary Optimization · doi:10.1007/s00158-005-0579-0 · Cited by 312 · cited 3×
“The general concept of analytical target cascading (ATC) is similar to the auxiliary problem principle (APP) and alternating direction method of multipliers (ADMM) [20], [23], [33]–[35].”
BackgroundMethodConvergence Properties of Analytical Target Cascading
Michelena, N., Park, H., & Papalambros, P. Y. (2003) · AIAA Journal · doi:10.2514/2.2025 · Cited by 304 · cited 5×
“The ATC structure converges to first order optimality conditions, if the problem is convex [35].”
BackgroundResultInfluentialKargarian, A., Mohammadi, J., Guo, J., Chakrabarti, S., Barati, M., Hug, G., Kar, S., & Baldick, R. (2018) · IEEE Transactions on Smart Grid · doi:10.1109/tsg.2016.2614904 · Cited by 302 · cited 3×
“The performance of the algorithms depends on the type of the problem and initial values of variables and penalty multipliers/factors (refer to [3] for more details).”
BackgroundMethodInfluentialSelf-citation
Cited by
He, F., Zhou, J., Feng, Z.-K., Liu, G., & Yang, Y. (2019) · Applied Energy · doi:10.1016/j.apenergy.2019.01.055 · Cited by 342
A Review on TSO-DSO Coordination Models and Solution Techniques
Givisiez, A. G., Petrou, K., & Ochoa, L. F. (2020) · Electric Power Systems Research · doi:10.1016/j.epsr.2020.106659 · Cited by 200
Xie, C., Hong, Y., Ding, Y., Li, Y., & Radcliffe, J. (2018) · Applied Energy · doi:10.1016/j.apenergy.2018.04.074 · Cited by 113
Metadata
- Authors
- Mohammadi, A., Mehrtash, M., & Kargarian, A.
- Venue
- IEEE Transactions on Smart Grid
- Published
- 2019-05
- Volume
- 10
- Issue
- 3
- Pages
- 2358-2370
- ISSN
- 1949-3053 (ISSN-L)
- 1949-3061
- OpenAlex
- W2787445098
- Cited by
- 210
- References
- 28
- FWCI
- 10.82
- Type
- journal article
- Language
- en
- Open access
- green
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.