Grid-Synchronization Stability Analysis and Loop Shaping for PLL-Based Power Converters With Different Reactive Power Control
The DOI matches its Crossref record; 28 of the 28 references it cites were found in a registry or an index.
Abstract
Power converters may lose synchronization with the remaining network when integrated in a weak power grid. Such an instability phenomenon [known as grid-synchronization instability (GSI)] features the frequency divergence of phase-locked loop (PLL) and oscillations of the converter's power output. In this paper, we focus on the influences of reactive power control (RPC) methods on GSI. We develop a single-input-single-output model to explicitly reveal how the PLL interacts with the other parts of the converter system in terms of grid synchronization. Then, after deriving the open-loop transfer function and sensitivity function of the entire converter system, we compare the stability margins for different RPC methods. Furthermore, we elaborate on the interactions among RPC, PLL, and voltage feedforward (VFF), and then demonstrate that different design methods of RPC and VFF will lead to different stability margins. The subsequent stability analysis provides insightful guidelines for coordinating the design of multiple control loops, i.e., RPC, VFF and PLL. In particular, we demonstrate how the loop shaping of PLL takes effect in increasing the stability margin and eventually preventing the converter from GSI. The validity of the stability analysis is verified through simulations in MATLAB/Simulink.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Control of Power Converters in AC Microgrids
Rocabert, J., Luna, A., Blaabjerg, F., & Rodríguez, P. (2012) · IEEE Transactions on Power Electronics · doi:10.1109/tpel.2012.2199334 · Cited by 3,723 · cited 4×
“Particularly, there exist several typical RPC methods for power converters, including constant reactive power control (CRPC), constant acbus voltage control (CVC) and reactive power-voltage droop control (QVC) [30]–[32].”
BackgroundMethodInfluential(2004) · IEEE Transactions on Power Systems · doi:10.1109/tpwrs.2004.825981 · Cited by 3,719 · cited 1×
“These instability phenomena have been adequately studied in existing literature such as [12].”
BackgroundOlivares, D. E., Mehrizi-Sani, A., Etemadi, A. H., Canizares, C. A., Iravani, R., Kazerani, M., Hajimiragha, A. H., Gomis-Bellmunt, O., Saeedifard, M., Palma-Behnke, R., et al. (2014) · IEEE Transactions on Smart Grid · doi:10.1109/tsg.2013.2295514 · Cited by 3,137
Modeling, Analysis and Testing of Autonomous Operation of an Inverter-Based Microgrid
Pogaku, N., Prodanovic, M., & Green, T. C. (2007) · IEEE Transactions on Power Electronics · doi:10.1109/tpel.2006.890003 · Cited by 3,018 · cited 1×
“Instead of modeling a power converter via a state space model, an impedance model or complex transfer function matrices [3], [18], [37]–[38], here we model the converter as a SISO system by focusing on the dynamics of θ in response to θg.”
MethodImpedance-Based Stability Criterion for Grid-Connected Inverters
Sun, J. (2011) · IEEE Transactions on Power Electronics · doi:10.1109/tpel.2011.2136439 · Cited by 2,574 · cited 2×
“Instead of modeling a power converter via a state space model, an impedance model or complex transfer function matrices [3], [18], [37]–[38], here we model the converter as a SISO system by focusing on the dynamics of θ in response to θg.”
BackgroundMethodDecoupled Double Synchronous Reference Frame PLL for Power Converters Control
Rodriguez, P., Pou, J., Bergas, J., Candela, J. I., Burgos, R. P., & Boroyevich, D. (2007) · IEEE Transactions on Power Electronics · doi:10.1109/tpel.2006.890000 · Cited by 1,359 · cited 1×
“, decoupled double synchronous reference frame [19], enhanced PLL [20] or those using the calculated angle error as the input, may also result in an asymmetric converter model in the dq-frame due to the voltage orientation effect.”
BackgroundAnalysis of D-Q Small-Signal Impedance of Grid-Tied Inverters
Wen, B., Boroyevich, D., Burgos, R., Mattavelli, P., & Shen, Z. (2016) · IEEE Transactions on Power Electronics · doi:10.1109/tpel.2015.2398192 · Cited by 1,334 · cited 4×
“The analysis in [9] has shown that GSI would be potentially caused by the negative resistance of the power converter’s q-q channel impedance, which falls into the category of small-signal stability.”
BackgroundInfluentialPower-Synchronization Control of Grid-Connected Voltage-Source Converters
Zhang, L., Harnefors, L., & Nee, H.-P. (2010) · IEEE Transactions on Power Systems · doi:10.1109/tpwrs.2009.2032231 · Cited by 1,317
Multivariable Feedback Control
(2005) · Advances in Industrial Control · doi:10.1007/1-84628-092-3_5 · Cited by 1,288
Impedance Modeling and Analysis of Grid-Connected Voltage-Source Converters
Cespedes, M., & Sun, J. (2014) · IEEE Transactions on Power Electronics · doi:10.1109/tpel.2013.2262473 · Cited by 1,167 · cited 1×
“or complex transfer functions [18], [27].”
Cited by
Placing Grid-Forming Converters to Enhance Small Signal Stability of PLL-Integrated Power Systems
Yang, C., Huang, L., Xin, H., & Ju, P. (2021) · IEEE Transactions on Power Systems · doi:10.1109/tpwrs.2020.3042741 · Cited by 279
Self-citationGrid-Forming and Spatially Distributed Control Design of Dynamic Virtual Power Plants
Häberle, V., Tayyebi, A., He, X., Prieto-Araujo, E., & Dörfler, F. (2024) · IEEE Transactions on Smart Grid · doi:10.1109/tsg.2023.3311481 · Cited by 58
Metadata
- Authors
- Huang, L., Xin, H., Li, Z., Ju, P., Yuan, H., Lan, Z., & Wang, Z.
- Venue
- IEEE Transactions on Smart Grid
- Published
- 2020-01
- Volume
- 11
- Issue
- 1
- Pages
- 501-516
- ISSN
- 1949-3053 (ISSN-L)
- 1949-3061
- OpenAlex
- W2950016236
- Cited by
- 252
- References
- 28
- FWCI
- 13.18
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.