A FDI Attack-Resilient Distributed Secondary Control Strategy for Islanded Microgrids
The DOI matches its Crossref record; 21 of the 21 references it cites were found in a registry or an index.
Abstract
Distributed cooperative control has been used as a preferred secondary control strategy for maintaining frequency synchronization and voltage restoration in cyber-physical AC microgrids due to its flexibility, scalability and better computational performance. However, such a control system is susceptible to potential cyber attacks, i.e., false data injection (FDI) attacks. To this end, this article introduces a hidden layer based attack-resilient distributed cooperative control algorithm to solve the problem of the secondary control of islanded microgrids under FDI attacks. In comparison to the existing attack-resilient distributed control methods, the proposed controller with sufficient large α can mitigate the adverse effects of time dependent FDI attacks on actuators, sensors and communication links of the control system, and is also robust to state dependent FDI attacks. Furthermore, the algorithm is applicable even when all DGs and communications are compromised. Finally, the efficiency of the proposed controller is evaluated for a test microgrid with 4 DGs under different types of attack.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Guerrero, J. M., Vasquez, J. C., Matas, J., de Vicuna, L. G., & Castilla, M. (2011) · IEEE Transactions on Industrial Electronics · doi:10.1109/tie.2010.2066534 · Cited by 5,075 · cited 2×
“Droop mechanism prescribes linear relation between the frequency and the active power, and between the voltage amplitude and the reactive power, which is typically denoted by [3] where v i and ω i are the voltage amplitude and frequency of DG i respectively.”
BackgroundHierarchical Structure of Microgrids Control System
Bidram, A., & Davoudi, A. (2012) · IEEE Transactions on Smart Grid · doi:10.1109/tsg.2012.2197425 · Cited by 1,515 · cited 1×
“As for the control structure of MGs, the hierarchical control is a standardized framework, which is typically classified into three layers, i.e., the primary, secondary, and tertiary control levels [3], [4].”
BackgroundCyber–Physical Security of a Smart Grid Infrastructure
Mo, Y., Kim, T. H.-J., Brancik, K., Dickinson, D., Lee, H., Perrig, A., & Sinopoli, B. (2012) · Proceedings of the IEEE · doi:10.1109/jproc.2011.2161428 · Cited by 1,096
Cooperative Control of Dynamical Systems
(2009) · Journal of International Crisis and Risk Communication Research · doi:10.1007/978-1-84882-325-9 · Cited by 985
Resilient Asymptotic Consensus in Robust Networks
LeBlanc, H. J., Zhang, H., Koutsoukos, X., & Sundaram, S. (2013) · IEEE Journal on Selected Areas in Communications · doi:10.1109/jsac.2013.130413 · Cited by 730 · cited 1×
“…to ensure attack-resilient operation, some works assume that more than half of the attacked DG’s neighbors should be healthy [14], [15], [24], which is a rather strict assumption for applications since attackers could corrupt any DG if they can get access to, and even corrupt all the…”
BackgroundSecondary control of microgrids based on distributed cooperative control of multi‐agent systems
Bidram, A., Davoudi, A., Lewis, F. L., & Qu, Z. (2013) · IET Generation, Transmission & Distribution · doi:10.1049/iet-gtd.2012.0576 · Cited by 541 · cited 1×
“The secondary frequency control of a MG including N DGs can be transformed into a synchronization problem for a first order and linear multi-agent system, and the procedure is as follows [7], [14], [28].”
BackgroundDistributed tracking control of leader–follower multi-agent systems under noisy measurement
Hu, J., & Feng, G. (2010) · Automatica · doi:10.1016/j.automatica.2010.05.020 · Cited by 488
(2014) · IEEE Control Systems · doi:10.1109/mcs.2014.2350571 · Cited by 344 · cited 3×
“The secondary frequency control of a MG including N DGs can be transformed into a synchronization problem for a first order and linear multi-agent system, and the procedure is as follows [7], [14], [28].”
BackgroundMethodDetection of False-Data Injection Attacks in Cyber-Physical DC Microgrids
Beg, O. A., Johnson, T. T., & Davoudi, A. (2017) · IEEE Transactions on Industrial Informatics · doi:10.1109/tii.2017.2656905 · Cited by 297 · cited 1×
“…FDI attacks or stealthy attacks on sensors or communication links of secondary voltage control system of DC MGs. Analogously, the authors in [13] dealt with this problem by transforming attack detection problem into identifying the variable in inferred candidate invariant MGs properties’…”
BackgroundA Distributed Algorithm for Solving a Linear Algebraic Equation
Mou, S., Liu, J., & Morse, A. S. (2015) · IEEE Transactions on Automatic Control · doi:10.1109/tac.2015.2414771 · Cited by 284
A Stealth Cyber-Attack Detection Strategy for DC Microgrids
Sahoo, S., Mishra, S., Peng, J. C., & Dragičević, T. (2018) · IEEE Transactions on Power Electronics · doi:10.1109/tpel.2018.2879886 · Cited by 268 · cited 2×
“Most of the existing algorithms only deal with one specific kind of attack, which is not in line with the practice applications since the injections can be in various forms [11], [12], [14], [15], [18]–[23].”
BackgroundZhao, J., Mili, L., & Wang, M. (2018) · IEEE Transactions on Power Systems · doi:10.1109/tpwrs.2018.2794468 · Cited by 202 · cited 2×
“Most of the existing algorithms only deal with one specific kind of attack, which is not in line with the practice applications since the injections can be in various forms [11], [12], [14], [15], [18]–[23].”
BackgroundSynchrony in Networked Microgrids Under Attacks
Abhinav, S., Modares, H., Lewis, F. L., Ferrese, F., & Davoudi, A. (2018) · IEEE Transactions on Smart Grid · doi:10.1109/tsg.2017.2721382 · Cited by 187 · cited 9×
“The observer-based secondary control of DG i in [14] is given by ˙ˆ ω i = where ˆ ω i is the frequency observed at DG i .”
BackgroundMethodResultInfluentialDistributed Load Sharing Under False Data Injection Attack in an Inverter-Based Microgrid
Zhang, H., Meng, W., Qi, J., Wang, X., & Zheng, W. X. (2019) · IEEE Transactions on Industrial Electronics · doi:10.1109/tie.2018.2793241 · Cited by 185 · cited 2×
“Among them, FDI attacks are the most common and typical attack forms for distributed control systems [9]–[16], which will maliciously destroy the control performance by injecting false information to corrupt the real information.”
BackgroundResilient and Robust Synchronization of Multiagent Systems Under Attacks on Sensors and Actuators
Modares, H., Kiumarsi, B., Lewis, F. L., et al. (2019) · IEEE Transactions on Cybernetics · doi:10.1109/tcyb.2019.2903411 · Cited by 146 · cited 1×
“Most of the existing algorithms only deal with one specific kind of attack, which is not in line with the practice applications since the injections can be in various forms [11], [12], [14], [15], [18]–[23].”
BackgroundCompetitive Interaction Design of Cooperative Systems Against Attacks
Gusrialdi, A., Qu, Z., & Simaan, M. A. (2018) · IEEE Transactions on Automatic Control · doi:10.1109/tac.2018.2793164 · Cited by 139 · cited 6×
“In addition, the interconnection matrices corresponding to the communication networks can be designed to be sparse as well to reduce the communication burden [26].”
BackgroundMethodInfluentialResilient Distributed DC Optimal Power Flow Against Data Integrity Attack
Duan, J., Zeng, W., & Chow, M. (2016) · IEEE Transactions on Smart Grid · doi:10.1109/tsg.2016.2633943 · Cited by 108
Gusrialdi, A., & Qu, Z. (2017) · IEEE Control Systems Letters · doi:10.1109/lcsys.2017.2717799 · Cited by 73 · cited 1×
“Remark 1: Noting that matrix H has no requirement on connectivity but Hurwitz and invertibility, it can be obtained distributively using Gershgorin theorem [31].”
MethodDistributed Noise-Resilient Networked Synchrony of Active Distribution Systems
Abhinav, S., Schizas, I. D., Lewis, F. L., & Davoudi, A. A. (2016) · IEEE Transactions on Smart Grid · doi:10.1109/tsg.2016.2569602 · Cited by 62
A future outlook for cyber-physical power system
Su, Z., Xu, L., Xin, S., Li, W., Shi, Z., & Guo, Q. (2017) · IEEE Conference on Energy Internet and Energy System Integration (EI2) · doi:10.1109/ei2.2017.8245733 · Cited by 23 · cited 1×
“W ITH advanced computing and communication components being equipped extensively, active power distribution systems have evolved into Cyber-Physical Systems (CPSs) with tight integration and cooperation between cyber and electrical spaces [1], [2].”
BackgroundLeader–follower synchronisation of autonomous agents with external disturbances
Liu, Y., & Lunze, J. (2014) · International Journal of Control · doi:10.1080/00207179.2014.893588 · Cited by 14 · cited 1×
“Most of the existing algorithms only deal with one specific kind of attack, which is not in line with the practice applications since the injections can be in various forms [11], [12], [14], [15], [18]–[23].”
Background
Cited by
Xu, L., Guo, Q., Sheng, Y., Muyeen, S. M., & Sun, H. (2021) · Renewable and Sustainable Energy Reviews · doi:10.1016/j.rser.2021.111642 · Cited by 168
Grid integration impacts and control strategies for renewable based microgrid
Fazal, S., Enamul Haque, M., Taufiqul Arif, M., Gargoom, A., & Oo, A. M. T. (2023) · Sustainable Energy Technologies and Assessments · doi:10.1016/j.seta.2023.103069 · Cited by 74
Metadata
- Authors
- Chen, Y., Qi, D., Dong, H., Li, C., Li, Z., & Zhang, J.
- Venue
- IEEE Transactions on Smart Grid
- Published
- 2021-05
- Volume
- 12
- Issue
- 3
- Pages
- 1929-1938
- ISSN
- 1949-3053 (ISSN-L)
- 1949-3061
- OpenAlex
- W3115295331
- Cited by
- 216
- References
- 21
- FWCI
- 9.69
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.