The DOI matches its Crossref record; 20 of the 20 references it cites were found in a registry or an index.
Applications of the signal space separation method
Abstract
The reliability of biomagnetic measurements is traditionally challenged by external interference signals, movement artifacts, and comparison problems caused by different positions of the subjects or different sensor configurations. The Signal Space Separation method (SSS) idealizes magnetic multichannel signals by transforming them into device-independent idealized channels representing the measured data in uncorrelated form. The transformation has separate components for the biomagnetic and external interference signals, and thus, the biomagnetic signals can be reconstructed simply by leaving out the contribution of the external interference. The foundation of SSS is a basis spanning all multichannel signals of magnetic origin. It is based on Maxwell's equations and the geometry of the sensor array only, with the assumption that the sensors are located in a current free volume. SSS is demonstrated to provide suppression of external interference signals, standardization of different positions of the subject, standardization of different sensor configurations, compensation for distortions caused by movement of the subject (even a subject containing magnetic impurities), suppression of sporadic sensor artifacts, a tool for fine calibration of the device, extraction of biomagnetic DC fields, and an aid for realizing an active compensation system. Thus, SSS removes many limitations of traditional biomagnetic measurements.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Golub, G. (2012) · doi:10.56021/9781421407944 · Cited by 34,505
Greiner, W. (1998) · Theoretical Physics · doi:10.1007/978-1-4612-0587-6 · Cited by 6,657
Hämäläinen, M., Hari, R., Ilmoniemi, R. J., Knuutila, J., & Lounasmaa, O. V. (1993) · Reviews of Modern Physics · doi:10.1103/revmodphys.65.413 · Cited by 4,684
Mathematical Methods for Physicists
(1985) · Elsevier eBooks · doi:10.1016/c2013-0-10310-8 · Cited by 2,777
Basic mathematical and electromagnetic concepts of the biomagnetic inverse problem
Sarvas, J. (1987) · Physics in Medicine and Biology · doi:10.1088/0031-9155/32/1/004 · Cited by 1,843
A subfemtotesla multichannel atomic magnetometer
Kominis, I. K., Kornack, T. W., Allred, J. C., & Romalis, M. V. (2003) · Nature · doi:10.1038/nature01484 · Cited by 1,631 · cited 1×
“In principle, any direction in the signal space represents a valid result of a magnetic field measurement.”
BackgroundSignal-space projection method for separating MEG or EEG into components
Uusitalo, M. A., & Ilmoniemi, R. J. (1997) · Medical & Biological Engineering & Computing · doi:10.1007/bf02534144 · Cited by 913
Signal Processing in Magnetoencephalography
Vrba, J., & Robinson, S. E. (2001) · Methods · doi:10.1006/meth.2001.1238 · Cited by 716 · cited 1×
“The potential with is associated with the field of a magnetic monopole and is therefore excluded from the expansion.”
BackgroundSuppression of Interference and Artifacts by the Signal Space Separation Method
Taulu, S., Kajola, M., & Simola, J. (2004) · Brain Topography · doi:10.1023/b:brat.0000032864.93890.f9 · Cited by 541
Self-citationPresentation of electromagnetic multichannel data: The signal space separation method
Taulu, S., & Kajola, M. (2005) · Journal of Applied Physics · doi:10.1063/1.1935742 · Cited by 390
Self-citation
Cited by
MNE software for processing MEG and EEG data
Gramfort, A., Luessi, M., Larson, E., Engemann, D. A., Strohmeier, D., Brodbeck, C., Parkkonen, L., & Hämäläinen, M. S. (2014) · NeuroImage · doi:10.1016/j.neuroimage.2013.10.027 · Cited by 1,951
Spatiotemporal signal space separation method for rejecting nearby interference in MEG measurements
Taulu, S., & Simola, J. (2006) · Physics in Medicine and Biology · doi:10.1088/0031-9155/51/7/008 · Cited by 1,549
Self-citationTaylor, J. R., Williams, N., Cusack, R., Auer, T., Shafto, M. A., Dixon, M., Tyler, L. K., Cam-CAN, & Henson, R. N. (2017) · NeuroImage · doi:10.1016/j.neuroimage.2015.09.018 · Cited by 782
Phase-Locked Responses to Speech in Human Auditory Cortex are Enhanced During Comprehension
Peelle, J. E., Gross, J., & Davis, M. H. (2013) · Cerebral Cortex · doi:10.1093/cercor/bhs118 · Cited by 568
Brookes, M. J., Leggett, J., Rea, M., Hill, R. M., Holmes, N., Boto, E., & Bowtell, R. (2022) · Trends in Neurosciences · doi:10.1016/j.tins.2022.05.008 · Cited by 412
MEG: An Introduction to Methods
(2010) · Oxford University Press eBooks · doi:10.1093/acprof:oso/9780195307238.001.0001 · Cited by 408
Predictive top-down integration of prior knowledge during speech perception
Sohoglu, E., Peelle, J. E., Carlyon, R. P., & Davis, M. H. (2012) · Journal of Neuroscience · doi:10.1523/jneurosci.5069-11.2012 · Cited by 388
“Data from the MEG sensors (magnetometers and gradiometers) were processed using the temporal extension of Signal Source Separation (Taulu et al., 2005) in Maxfilter to suppress noise sources, compensate for motion, and reconstruct any bad sensors.”
MethodTaulu, S., & Hari, R. (2009) · Human Brain Mapping · doi:10.1002/hbm.20627 · Cited by 369
Self-citationCabral, J., Luckhoo, H., Woolrich, M., Joensson, M., Mohseni, H., Baker, A., Kringelbach, M. L., & Deco, G. (2014) · NeuroImage · doi:10.1016/j.neuroimage.2013.11.047 · Cited by 326
On-scalp MEG system utilizing an actively shielded array of optically-pumped magnetometers
Iivanainen, J., Zetter, R., Grön, M., Hakkarainen, K., & Parkkonen, L. (2019) · NeuroImage · doi:10.1016/j.neuroimage.2019.03.022 · Cited by 269
Holmes, N., Leggett, J., Boto, E., Roberts, G., Hill, R. M., Tierney, T. M., Shah, V., Barnes, G. R., Brookes, M. J., & Bowtell, R. (2018) · NeuroImage · doi:10.1016/j.neuroimage.2018.07.028 · Cited by 250
“Although several valuable approaches for compensating for head movement within the confines of the conventional MEG helmet have been developed (Nenonen et al., 2012; Taulu et al., 2005; Wehner et al., 2008), large gross motion (e.”
BackgroundThe pace of prosodic phrasing couples the listener’s cortex to the reader’s voice
Bourguignon, M., De Tiège, X., de Beeck, M. O., Ligot, N., Paquier, P., Van Bogaert, P., Goldman, S., Hari, R., & Jousmäki, V. (2013) · Human Brain Mapping · doi:10.1002/hbm.21442 · Cited by 147
Chennu, S., Noreika, V., Gueorguiev, D., Shtyrov, Y., Bekinschtein, T. A., & Henson, R. (2016) · Journal of Neuroscience · doi:10.1523/jneurosci.1125-16.2016 · Cited by 107
A 90-Channel Triaxial Magnetoencephalography System Using Optically Pumped Magnetometers
Rea, M., Boto, E., Holmes, N., Hill, R., Osborne, J., Rhodes, N., Leggett, J., Rier, L., Bowtell, R., Shah, V., et al. (2022) · Annals of the New York Academy of Sciences · doi:10.1111/nyas.14890 · Cited by 102
Franzen, J. D., Heinrichs-Graham, E., White, M. L., Wetzel, M. W., Knott, N. L., & Wilson, T. W. (2013) · Journal of Psychiatry and Neuroscience · doi:10.1503/jpn.120054 · Cited by 55
“15; Elekta), MEG data from each session and participant were transformed into a standard device-centred head position, individually corrected for head motion, coregistered to structural MRI and subjected to noise reduction using the signal space separation method with a temporal extension (tSSS).(28,29)”
MethodWens, V., Bourguignon, M., Vander Ghinst, M., Mary, A., Marty, B., Coquelet, N., Naeije, G., Peigneux, P., Goldman, S., & De Tiège, X. (2019) · NeuroImage · doi:10.1016/j.neuroimage.2019.05.081 · Cited by 51
“2 with default parameters) in order to suppress external magnetic interferences and correct for head movements (Taulu et al., 2005).”
BackgroundSleep in children triggers rapid reorganization of memory-related brain processes
Urbain, C., De Tiège, X., Op De Beeck, M., Bourguignon, M., Wens, V., Verheulpen, D., Van Bogaert, P., & Peigneux, P. (2016) · NeuroImage · doi:10.1016/j.neuroimage.2016.03.055 · Cited by 44
Parsons, C. E., Young, K. S., Mohseni, H., Woolrich, M. W., Thomsen, K. R., Joensson, M., Murray, L., Goodacre, T., Stein, A., & Kringelbach, M. L. (2013) · Social Neuroscience · doi:10.1080/17470919.2013.795189 · Cited by 48
Infant brain imaging using magnetoencephalography: Challenges, solutions, and best practices
Clarke, M. D., Bosseler, A. N., Mizrahi, J. C., Peterson, E. R., Larson, E., Meltzoff, A. N., Kuhl, P. K., & Taulu, S. (2022) · Human Brain Mapping · doi:10.1002/hbm.25871 · Cited by 21
Self-citationMellot, A., Collas, A., Rodrigues, P. L. C., Engemann, D., & Gramfort, A. (2023) · Imaging Neuroscience · doi:10.1162/imag_a_00040 · Cited by 16
Metadata
- Authors
- Taulu, S., Simola, J., & Kajola, M.
- Venue
- IEEE Transactions on Signal Processing
- Published
- 2005-09
- Volume
- 53
- Issue
- 9
- Pages
- 3359-3372
- ISSN
- 1053-587X (ISSN-L)
- OpenAlex
- W2106628957
- Cited by
- 548
- References
- 20
- FWCI
- 3.42
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.