An Online Swallow Detection Algorithm Based on the Quadratic Variation of Dual-Axis Accelerometry
The DOI matches its Crossref record; 27 of the 28 references it cites were found in a registry or an index.
Abstract
Swallow accelerometry is an emerging tool for noninvasive dysphagia screening. However, the automatic detection of a swallowing event is challenging due to contaminant vibrations arising from head motion, speech and coughing. In this paper, we consider the acceleration signal as a stochastic diffusion where movement is associated with drift and swallowing with volatility. Using this model, we develop a volatility-based swallow event detector that operates on the raw acceleration signal in an online fashion. With data from healthy participants and patients with dysphagia, the proposed detector achieves performance comparable to previously proposed swallow segmentation algorithms, with the added benefit of online detection and no signal pre-processing. The volatility-based detector may be useful for event identification in other biomechanical applications that rely on accelerometry signals.
Overview
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
Claims other papers make about this one
Each is checked against this paper’s own text: does it say what the citing paper says it does?
In the citing paper
“The best performing channel was the A-P accelerometer axis with an average accuracy of 89.44% for single swallows (75.9% for the whole dataset) and superior sensitivity and specificity which is comparable to the results in7.”
From Non-invasive identification of swallows via deep learning in high resolution cervical auscultation recordings (2020) · cites this paper as [7]
In the citing paper
“Damouras et al.7 used quadratic variation that is extracted directly from acceleration signals to perform segmentation and the algorithm was computationally effective to execute.”
From Non-invasive identification of swallows via deep learning in high resolution cervical auscultation recordings (2020) · cites this paper as [7]
In the citing paper
“Their algorithm achieved recall values up to 94% but it was highly affected by the presence of noise and the used dataset wasn’t diverse enough considering the maneuvers and material consistencies.”
From Non-invasive identification of swallows via deep learning in high resolution cervical auscultation recordings (2020) · cites this paper as [7]
In the citing paper
“a typical swallow segment can range in duration from 1 second (4k samples in this case) to more than 3 seconds which makes the selected window sizes robust to statistical error and efficient to detect the shortest swallows7,36.”
From Non-invasive identification of swallows via deep learning in high resolution cervical auscultation recordings (2020) · cites this paper as [7]
Citations
Cites
Brownian Motion and Stochastic Calculus
(2007) · Springer Finance · doi:10.1007/978-1-84628-696-4_13 · Cited by 7,422
Econometric Analysis of Realized Volatility and its Use in Estimating Stochastic Volatility Models
Barndorff-Nielsen, O. E., & Shephard, N. (2002) · Journal of the Royal Statistical Society Series B: Statistical Methodology · doi:10.1111/1467-9868.00336 · Cited by 2,215 · cited 1×
“measuring stock market variability [17].”
Seidler, J. (1991) · Acta Applicandae Mathematicae · doi:10.1007/bf00046894 · Cited by 2,090
A Tale of Two Time Scales: Determining Integrated Volatility with Noisy High Frequency Data
Zhang, L., Mykland, P., & Ait-Sahalia, Y. (2003) · National Bureau of Economic Research · doi:10.3386/w10111 · Cited by 1,373
A Tale of Two Time Scales: Determining Integrated Volatility With Noisy High-Frequency Data
Zhang, L., Mykland, P. A., & Aït-Sahalia, Y. (2005) · Journal of the American Statistical Association · doi:10.1198/016214505000000169 · Cited by 1,306
A study of retrospective and on-line event detection
Yang, Y., Pierce, T., & Carbonell, J. (1998) · Proceedings of the 21st annual international ACM SIGIR conference on Research and development in information retrieval · doi:10.1145/290941.290953 · Cited by 731 · cited 1×
“Based on these quantities we use the following standard measures from information retrieval [22], [ 23 ] to assess the performance of our algorithm.”
MethodKernels for Nonparametric Curve Estimation
Gasser, T., MÜller, H.-G., & Mammitzsch, V. (1985) · Journal of the Royal Statistical Society Series B: Statistical Methodology · doi:10.1111/j.2517-6161.1985.tb01350.x · Cited by 470 · cited 2×
“We do this by estimating the second derivative of using a kernel smoother, as (10) where is optimal for estimating second derivatives [20], and and have the same values as those used for estimating .”
BackgroundMethodDrowsy Driver Detection Through Facial Movement Analysis
Vural, E., Cetin, M., Ercil, A., Littlewort, G., Bartlett, M., & Movellan, J. (2007) · Lecture Notes in Computer Science · doi:10.1007/978-3-540-75773-3_2 · Cited by 232 · cited 1×
“Example applications include the detection of feeding activities [1] and driver drowsiness [2], the assessment of fall risk in the aged [3], the quantification of muscle contractions [4], the monitoring of cardio-respiratory activity [5], the study of head angular accelerations in impact injuries [6], the tracking of…”
BackgroundDurational aspects of the oral-pharyngeal phase of swallow in normal adults
Sonies, B. C., Parent, L. J., Morrish, K., & Baum, B. J. (1988) · Dysphagia · doi:10.1007/bf02406274 · Cited by 185 · cited 1×
“For all three measures, values closer to one indicate better performance.”
BackgroundMicrostructure noise, realized volatility, and optimal sampling
Bandi, F. M. (2008) · Cited by 92
Cited by
Lee, K., Ni, X., Lee, J. Y., Arafa, H., Pe, D. J., Xu, S., Avila, R., Irie, M., Lee, J. H., Easterlin, R. L., et al. (2019) · Nature Biomedical Engineering · doi:10.1038/s41551-019-0480-6 · Cited by 349
A Novel Wearable Device for Food Intake and Physical Activity Recognition
Farooq, M., & Sazonov, E. (2016) · Sensors · doi:10.3390/s16071067 · Cited by 128
“However, they are not able to reliably distinguish swallows from the head and neck movements and, therefore, their use in free-living conditions is limited [34].”
BackgroundKang, Y. J., Arafa, H., Yoo, J., Kantarcigil, Ç., Kim, J., Jeong, H., Yoo, S., Oh, S., Kim, J., Wu, C., et al. (2022) · npj Digital Medicine · doi:10.1038/s41746-022-00691-w · Cited by 102
Dudik, J. M., Coyle, J. L., & Sejdic, E. (2015) · IEEE Transactions on Human-Machine Systems · doi:10.1109/thms.2015.2408615 · Cited by 86
Khalifa, Y., Coyle, J. L., & Sejdić, E. (2020) · Scientific Reports · doi:10.1038/s41598-020-65492-1 · Cited by 82
“Since numerous physiologic and kinematic events occur simultaneously during swallowing recordings (e.g. breathing, coughing), collected signals contain vibratory and acoustic information from multiple sources 7 .”
BackgroundMethodResultInfluentialKhalifa, Y., Mandic, D. P., & Sejdić, E. (2020) · Information Fusion · doi:10.1016/j.inffus.2020.11.008 · Cited by 88
“Epoch extraction algorithms have been used repeatedly in segmentation of many biomedical signals, including, but not limited to, heart sound and ECG [9, 10], electroencephalography (EEG) [11–13], and swallowing vibrations [14–17].”
MethodDudik, J. M., Kurosu, A., Coyle, J. L., & Sejdić, E. (2015) · Computers in Biology and Medicine · doi:10.1016/j.compbiomed.2015.01.007 · Cited by 76
“Using the process described in the previous work we chose to use a k value of 200 points, corresponding to a subsampling rate of 10 ms with our higher sampling rate [35].”
BackgroundMethodResultInfluentialSejdić, E., Can, A., Chaparro, L. F., Steele, C. M., & Chau, T. T. (2012) · EURASIP Journal on Advances in Signal Processing · doi:10.1186/1687-6180-2012-101 · Cited by 63
“Recent contributions have indeed confirmed that dual-axis accelerometers yield more information and enhance analysis capabilities [38-43].”
BackgroundSelf-citationKhalifa, Y., Donohue, C., Coyle, J. L., & Sejdic, E. (2021) · IEEE Journal of Biomedical and Health Informatics · doi:10.1109/jbhi.2020.3000057 · Cited by 49
“collected vibratory and acoustic signals [34].”
Real-time swallowing detection based on tracheal acoustics
Prioleau, T., & Ghovanloo, M. (2014) · IEEE International Conference on Acoustics Speech and Signal Processing · doi:10.1109/icassp.2014.6854430 · Cited by 51
“A swallowing detection algorithm should be effective in retrieving correct events and omitting non-swallow events while maintaining low processing effort [8].”
BackgroundMethodQuantitative classification of pediatric swallowing through accelerometry
Celeste, M., Azadeh, K., Sejdić, E., Berall, G., & Chau, T. (2012) · Journal of NeuroEngineering and Rehabilitation · doi:10.1186/1743-0003-9-34 · Cited by 37
“[30] for swallowing signals.”
Self-citationAutomated Acoustic Analysis in Detection of Spontaneous Swallows in Parkinson’s Disease
Golabbakhsh, M., Rajaei, A., Derakhshan, M., Sadri, S., Taheri, M., & Adibi, P. (2014) · Dysphagia · doi:10.1007/s00455-014-9547-4 · Cited by 33
“In other reports [10–15], tracheal sound signal features were used to classify a tracheal sound segment as either a swallowing sound or a breath sound.”
BackgroundMethodHigh-resolution cervical auscultation and data science: new tools to address an old problem
Coyle, J. L., & Sejdić, E. (2020) · American Journal of Speech-Language Pathology · doi:10.1044/2020_ajslp-19-00155 · Cited by 28
“A number of different algorithms have been proposed over the years to segment swallowing signals into individual swallows (Damouras et al., 2010; Dudik, Jestrovi ć , et al., 2015; Sejdi ć et al., 2009).”
BackgroundMethodInfluentialSelf-citationSchultheiss, C., Schauer, T., Nahrstaedt, H., & Seidl, R. O. (2014) · The Scientific World JOURNAL · doi:10.1155/2014/405471 · Cited by 34
“Variousmeasurement procedures, including electromyography (EMG) [3] and accelerometers [4], have been studied in relation to this issue.”
BackgroundMethodA comparison between swallowing sounds and vibrations in patients with dysphagia
Movahedi, F., Kurosu, A., Coyle, J. L., Perera, S., & Sejdić, E. (2017) · Computer Methods and Programs in Biomedicine · doi:10.1016/j.cmpb.2017.03.009 · Cited by 28
“signals [1, 2, 3, 6, 8, 9, 12, 18, 21, 23, 27, 32], segmentation of the swallowing signals [20, 22, 27, 33, 34, 35, 36], and classification of an abnormal swallow 55”
BackgroundSilent Aspiration Detection in High Resolution Cervical Auscultations
Yu, C., Khalifa, Y., & Sejdic, E. (2019) · 2019 IEEE EMBS International Conference on Biomedical & Health Informatics (BHI) · doi:10.1109/bhi.2019.8834576 · Cited by 22
“coughing) [32].”
Shu, K., Mao, S., Coyle, J. L., & Sejdić, E. (2021) · IEEE Journal of Biomedical and Health Informatics · doi:10.1109/jbhi.2021.3106565 · Cited by 21
Detection and Characterization of Food Intake by Wearable Sensors
Fontana, J. M., & Sazonov, E. E. (2014) · Elsevier eBooks · doi:10.1016/b978-0-12-418662-0.00010-6 · Cited by 23
Khalifa, Y., Donohue, C., Coyle, J. L., & Sejdić, E. (2022) · IEEE Journal of Biomedical and Health Informatics · doi:10.1109/jbhi.2022.3224323 · Cited by 19
“Traditional event detection methods that rely on statistical and non-sequence-aware classification models have been heavily investigated for the extraction of swallow segments in HRCA signals [27], [28], [29], [30], [31], [32], [33].”
BackgroundSwallowing accelerometry signal feature variations with sensor displacement
Mamun, K. A., Steele, C. M., & Chau, T. T. (2015) · Medical Engineering & Physics · doi:10.1016/j.medengphy.2015.04.007 · Cited by 19
Self-citationSejdić, E., Falk, T. H., Steele, C. M., & Chau, T. T. (2010) · Medical Engineering & Physics · doi:10.1016/j.medengphy.2010.04.008 · Cited by 24
Self-citationA Mobile Food Intake Monitoring System based on Breathing Signal Analysis
Biswas, S., Dong, B., Gernhardt, R., & Schlemminger, J. (2013) · International Conference on Body Area Networks · doi:10.4108/icst.bodynets.2013.253586 · Cited by 14
Quantitative Real-Time Assessment for Feeding Skill of Preterm Infants
Chen, C.-T., Wang, L., Wang, Y., & Lin, B. (2017) · Journal of Medical Systems · doi:10.1007/s10916-017-0744-1 · Cited by 17
Swallow Detection Algorithm Based on Bioimpedance and EMG Measurements
Nahrstaedt, H., Schultheiss, C., Seidl, R. O., & Schauer, T. (2012) · IFAC Proceedings Volumes · doi:10.3182/20120829-3-hu-2029.00067 · Cited by 21
“First approaches in this direction have been based on dualaxis swallowing accelerometry signals (Sejdi et al., 2009; Damouras et al., 2010), dual-axis swallowing accelerometry signals in combination with nasal respiration and submental mechanomyography signals (Lee et al.”
BackgroundWearable sensing for liquid intake monitoring via apnea detection in breathing signals
Dong, B., & Biswas, S. K. (2014) · Biomedical Engineering Letters · doi:10.1007/s13534-014-0149-8 · Cited by 13
Development of Swallowing-Movement-Sensing Device and Swallowing-State-Estimation System
Kurihara, Y., Kaburagi, T., Kumagai, S., & Matsumoto, T. (2019) · IEEE Sensors Journal · doi:10.1109/jsen.2019.2894744 · Cited by 14
Khalifa, Y., Mahoney, A. S., Lucatorto, E., Coyle, J. L., & Sejdić, E. (2023) · IEEE Journal of Translational Engineering in Health and Medicine · doi:10.1109/jtehm.2023.3246919 · Cited by 14
“vibratory and acoustic signals by the used sensors [32].”
MethodDetection and characterization of food intake by wearable sensors
Fontana, J. M., Farooq, M., & Sazonov, E. E. (2020) · Elsevier eBooks · doi:10.1016/b978-0-12-819246-7.00020-6 · Cited by 15
Swallowing Events Recognition Method Based on Complex Impedance Pharyngography and Nyquist Plots
Zhang, F., Yu, S., Chen, P., Li, C., Lin, H., Li, J., Wu, Y., & Yang, Y. (2022) · IEEE Sensors Journal · doi:10.1109/jsen.2022.3196033 · Cited by 7
Post-Segmentation Swallowing Accelerometry Signal Trimming and False Positive Reduction
Mohammadi, H., Steele, C. M., & Chau, T. T. (2016) · IEEE Signal Processing Letters · doi:10.1109/lsp.2016.2566582 · Cited by 7
“Automatic segmentation by this method as well as by neural network [13] or quadratic variation [14] tend however, to yield segment boundaries that are too lenient, admitting non-swallow activity pre- and postswallow [see Fig.”
MethodSelf-citationWireless Monitoring System for Oral-Feeding Evaluation of Preterm Infants
Chen, C.-T., Wang, Y., Wang, C.-A., Ko, M.-J., Fang, W.-C., & Lin, B. (2015) · IEEE Transactions on Biomedical Circuits and Systems · doi:10.1109/tbcas.2015.2438031 · Cited by 7
“proposed the swallow detection algorithm based on the quadratic variation technique to detect swallowing activity from the dual-axis accelerometry signal, and its accuracy was more than 90% [22].”
Anwar, A., Khalifa, Y., Lucatorto, E., Coyle, J. L., & Sejdić, E. (2024) · Annual International Conference of the IEEE Engineering in Medicine and Biology Society (EMBC) · doi:10.1109/embc53108.2024.10782280 · Cited by 5
“HRCA signals with state-of-the-art signals preprocessing and machine learning algorithms have been shown to provide solid performance in swallowing assessment compared to the gold standard VFSS method [9]–[14].”
Portable auricular device for real-time swallow and chew detection
Steimer, K. C., Zimmermann, C., Zeilfelder, J., Pylatiuk, C., & Stork, W. (2016) · Current Directions in Biomedical Engineering · doi:10.1515/cdbme-2016-0031 · Cited by 4
“Stork) systems that work with acceleration sensors [4] or a combination of EMG and bioimpedance sensors [5] are principally portable, but special preparations are needed.”
BackgroundReputation-Based Neural Network Combinations
Nikjoo, M. S., Kushki, A., Lee, J., Steele, C. M., & Chau, T. T. (2011) · InTech eBooks · doi:10.5772/16194 · Cited by 2
“Specifically, the problem is to differentiate between safe and unsafe swallowing on the basis of dual-axis accelerometry (Damouras et al., 2010; Sejdic, Komisar, Steele & Chau, 2010).”
BackgroundSelf-citationBioimpedance Measurement to Evaluate Swallowing in a Patient with Amyotrophic Lateral Sclerosis
Zhang, F., McIlduff, C. E., Gutierrez, H. V., MacKenzie, S., & Rutkove, S. B. (2020) · World Congress on Medical Physics and Biomedical Engineering, September 7 - 12, 2009, Munich, Germany · doi:10.1007/978-981-13-3498-6_16 · Cited by 2
An accelerometry and gyroscopy-based system for detecting swallowing and coughing events
Stevens, G., de Velde, S. V., Larmuseau, M., Poelaert, J., Damme, A. V., & Verdonck, P. (2024) · Journal of Clinical Monitoring and Computing · doi:10.1007/s10877-024-01222-6 · Cited by 2
“Based on these quantities standard measures the following indicators [43] were used to assess the performance of our algorithm for as well swallowing as coughing actions.”
Galanis, C., Tsipianitis, D., & Michou, E. (2025) · International Conference on Information, Intelligence, Systems & Applications (IISA) · doi:10.1109/iisa66859.2025.11311258 · Cited by 1
High frequency factor analysis with partially observable factors
Chen, D., Lu, W., & Xie, S. (2025) · Journal of Econometrics · doi:10.1016/j.jeconom.2025.106058 · Cited by 1
High Frequency Factor Analysis with Partially Observable FactorsPreprint
Chen, D., Lu, W., & Xie, S. (2024) · SSRN Electronic Journal · doi:10.2139/ssrn.4968175 · Cited by 1
Diet monitoring through breathing signal analysis using wearable sensors
Dong, B. (2014) · Michigan State University Libraries · doi:10.25335/f5ms-jt75
Mohammadi, H. (2017) · TSpace (University of Toronto)
28 Diagnosis and Differential Diagnosis of Dysphagia
Angerstein, W., Farahat, M., Farneti, D., Graf, S., Jungheim, M., Kiagiadaki, D. E., Malki, K. H., Moerman, M., Müller, F., Nienstedt, J. C., et al. (2025) · European manual of medicine · doi:10.1007/978-3-031-48091-1_13
CFSCNet: A Coarse-Fine Stream Conformer Neural Network for Swallow Segmentation
Liu, Y., Lin, C., Wang, L. Y., Li, X., Cui, N., & Dou, Z. (2026) · IEEE Journal of Biomedical and Health Informatics · doi:10.1109/jbhi.2025.3650133
“Technological advancements have led to the development of various devices aimed at detecting and analyzing swallowing events without the drawbacks associated with VFSS [2], [3], [4], [5], [7], [35].”
Metadata
- Authors
- Damouras, S., Sejdic, E., Steele, C. M., & Chau, T.
- Affiliations
- Bloorview Research Institute (CA)
- University of Toronto (CA)
- Venue
- IEEE Transactions on Signal Processing
- Published
- 2010-06
- Volume
- 58
- Issue
- 6
- Pages
- 3352-3359
- ISSN
- 1053-587X (ISSN-L)
- 1941-0476
- OpenAlex
- W2167113242
- Cited by
- 43
- References
- 28
- Citations by year
- 2026: 1 · 2025: 3 · 2024: 3 · 2023: 1 · 2022: 3 · 2021: 1 · 2020: 6 · 2019: 3 · 2017: 3 · 2016: 3 · 2015: 4 · 2014: 6 · 2013: 1 · 2012: 3
- FWCI
- 5.34
- Type
- journal article
- Language
- en
- Open access
- closed
- Locations
- IEEE Transactions on Signal Processing (publishedVersion)
- Topics
- Health Sciences › Health Professions › Speech and Hearing › Dysphagia Assessment and Management
- Physical Sciences › Computer Science › Computer Vision and Pattern Recognition › Context-Aware Activity Recognition Systems
- Health Sciences › Health Professions › Speech and Hearing › Voice and Speech Disorders
- Keywords
- dysphagia screening, accelerometry, dual-axis accelerometer, quadratic variation, online detection, stochastic diffusion model
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).