The DOI matches its Crossref record; 25 of the 25 references it cites were found in a registry or an index.
Combined Central and Local Active and Reactive Power Control of PV Inverters
Abstract
The increasing amount of photovoltaic (PV) generation results in a reverse power flow and a violation of the overvoltage limits in distribution networks. PV inverters can curtail active power or consume reactive power to avoid these excessive high voltages. Local controllers of active and reactive power that are based on measurements of the produced PV power have a fast response to the changing production levels of the PV installation. The performance of these local controllers depends on the tuning of the control parameters, which are grid and time dependent. In this paper, local control functions are defined as piecewise linear functions. The parameters of all the local control functions are regularly reoptimized. This results in an optimal use of reactive power and a minimum amount of curtailed active power, while respecting network limitations. The optimization of these parameters is formulated as a convex optimization problem, which can be solved sufficiently fast. The performance of the control is evaluated on an existing three-phase four-wire distribution grid and is compared with different local control methods.
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
A Voltage and Frequency Droop Control Method for Parallel Inverters
De Brabandere, K., Bolsens, B., Van den Keybus, J., Woyte, A., Driesen, J., & Belmans, R. (2007) · IEEE Transactions on Power Electronics · doi:10.1109/tpel.2007.900456 · Cited by 1,865
Self-citationA three-phase power flow method for real-time distribution system analysis
Cheng, C. S., & Shirmohammadi, D. (1995) · IEEE Transactions on Power Systems · doi:10.1109/59.387902 · Cited by 854
Coordinated Active Power Curtailment of Grid Connected PV Inverters for Overvoltage Prevention
Tonkoski, R., Lopes, L. A. C., & El-Fouly, T. H. M. (2011) · IEEE Transactions on Sustainable Energy · doi:10.1109/tste.2010.2098483 · Cited by 822
Options for Control of Reactive Power by Distributed Photovoltaic Generators
Turitsyn, K., Sulc, P., Backhaus, S., & Chertkov, M. (2011) · Proceedings of the IEEE · doi:10.1109/jproc.2011.2116750 · Cited by 774
Optimal Charging of Electric Vehicles in Low-Voltage Distribution Systems
Richardson, P., Flynn, D., & Keane, A. (2012) · IEEE Transactions on Power Systems · doi:10.1109/tpwrs.2011.2158247 · Cited by 566
Centralized and Distributed Voltage Control: Impact on Distributed Generation Penetration
Vovos, P. N., Kiprakis, A. E., Wallace, A. R., & Harrison, G. P. (2007) · IEEE Transactions on Power Systems · doi:10.1109/tpwrs.2006.888982 · Cited by 545
Demirok, E., González, P. C., Frederiksen, K. H. B., Sera, D., Rodriguez, P., & Teodorescu, R. (2011) · IEEE Journal of Photovoltaics · doi:10.1109/jphotov.2011.2174821 · Cited by 530
Improved Low Voltage Grid-Integration of Photovoltaic Systems in Germany
Stetz, T., Marten, F., & Braun, M. (2013) · IEEE Transactions on Sustainable Energy · doi:10.1109/tste.2012.2198925 · Cited by 466
Validation of short and medium term operational solar radiation forecasts in the US
Perez, R., Kivalov, S., Schlemmer, J., Hemker, K., Renné, D., & Hoff, T. E. (2010) · Solar Energy · doi:10.1016/j.solener.2010.08.014 · Cited by 450
Optimal Distributed Control of Reactive Power Via the Alternating Direction Method of Multipliers
Sulc, P., Backhaus, S., & Chertkov, M. (2014) · IEEE Transactions on Energy Conversion · doi:10.1109/tec.2014.2363196 · Cited by 315
Cited by
Mitigating methods of power fluctuation of photovoltaic (PV) sources – A review
Shivashankar, S., Mekhilef, S., Mokhlis, H., & Karimi, M. (2016) · Renewable and Sustainable Energy Reviews · doi:10.1016/j.rser.2016.01.059 · Cited by 422
Zeraati, M., Hamedani Golshan, M. E., & Guerrero, J. M. (2018) · IEEE Transactions on Smart Grid · doi:10.1109/tsg.2016.2636217 · Cited by 395
Ghosh, S., Rahman, S., & Pipattanasomporn, M. (2017) · IEEE Transactions on Sustainable Energy · doi:10.1109/tste.2016.2577559 · Cited by 274
Methods and strategies for overvoltage prevention in low voltage distribution systems with PV
Hashemi, S., & Østergaard, J. (2017) · IET Renewable Power Generation · doi:10.1049/iet-rpg.2016.0277 · Cited by 212
Optimal local volt/var control for photovoltaic inverters in active distribution networks
Sun, X., Qiu, J., & Zhao, J. (2021) · IEEE Transactions on Power Systems · doi:10.1109/tpwrs.2021.3080039 · Cited by 111
Metadata
- Authors
- Weckx, S., Gonzalez, C., & Driesen, J.
- Venue
- IEEE Transactions on Sustainable Energy
- Published
- 2014-07
- Volume
- 5
- Issue
- 3
- Pages
- 776-784
- ISSN
- 1949-3029 (ISSN-L)
- 1949-3037
- OpenAlex
- W2105957522
- Cited by
- 281
- References
- 25
- FWCI
- 12.73
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Combined Central and Local Active and Reactive Power Control of PV Inverters. https://app.cochat.ai/papers/10.1109/tste.2014.2300934
- The paper
- Weckx, S., Gonzalez, C., & Driesen, J. (2014). Combined Central and Local Active and Reactive Power Control of PV Inverters. IEEE Transactions on Sustainable Energy. https://doi.org/10.1109/tste.2014.2300934
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.