Variable DC-Link Control Loop Design for an Integrated Two-Stage AC/DC Converter
The DOI matches its Crossref record; 4 of the 4 references it cites were found in a registry or an index.
Abstract
This paper presents an innovative technique of synthesizing variable dc-link voltage control loop for a two-stage integrated ac-dc converter, which is a cascaded combination of a single-phase continuous conduction mode interleaved totem-pole power factor correction and a half-bridge CLLC resonant converter. Although the variable dc-link control exhibits a better overall efficiency than the fixed dc-link control, it faces issues of: 1) loss of output voltage regulation and 2) low-frequency oscillations in the dc voltages and inductor current. In order to address and analyze these issues, both time-domain and frequency-domain studies of the control loop are performed, which led to two different voltage loop controller configurations, resolving the oscillation and regulation issues. As verification to the proof-of-concept, a hardware prototype of an integrated ac-dc converter is developed and tested up to 2 kW. The experimental results exhibit a power factor of 0.992, peak efficiency of >94% and a total harmonic distortion of <;5%, with the elimination of low-frequency oscillation of the dc voltage waveforms.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
High-Efficiency High-Density Critical Mode Rectifier/Inverter for WBG-Device-Based On-Board Charger
Liu, Z., Li, B., Lee, F. C., & Li, Q. (2017) · IEEE Transactions on Industrial Electronics · doi:10.1109/tie.2017.2716873 · Cited by 221 · cited 1×
“1) Requirement of intermediate dc-link voltage sensor in the variable dc-link control, proposed in [23] and [24] 2) High sensitivity of dc/dc stage gain variation upon any parameter uncertainty.”
BackgroundAn Electrolytic Capacitorless Bidirectional EV Charger for V2G and V2H Applications
Kwon, M., & Choi, S. (2017) · IEEE Transactions on Power Electronics · doi:10.1109/tpel.2016.2630711 · Cited by 177
Wang, X., Jiang, C., Lei, B., Teng, H., Bai, H. K., & Kirtley, J. L. (2016) · IEEE Journal of Emerging and Selected Topics in Power Electronics · doi:10.1109/jestpe.2016.2575921 · Cited by 107
Li, B., Lee, F. C., Li, Q., & Liu, Z. (2017) · 2017 IEEE Applied Power Electronics Conference and Exposition (APEC) · doi:10.1109/apec.2017.7931228 · Cited by 105 · cited 2×
“In the variable dc-link control loop, the dc-link reference is generated by multiplying the HV battery voltage by theoretically calculated dc/dc converter gain [23].”
BackgroundMethod
Cited by
He, P., Mallik, A., Sankar, A., & Khaligh, A. (2019) · IEEE Transactions on Vehicular Technology · doi:10.1109/tvt.2018.2881276 · Cited by 154
Self-citationMin, J., & Ordonez, M. (2021) · IEEE Transactions on Power Electronics · doi:10.1109/tpel.2020.3033982 · Cited by 152
Design of an Isolated DC/DC Topology With High Efficiency of Over 97% for EV Fast Chargers
Lee, W.-S., Kim, J.-H., Lee, J.-Y., & Lee, I.-O. (2019) · IEEE Transactions on Vehicular Technology · doi:10.1109/tvt.2019.2949080 · Cited by 111
“For example, the DC-link voltage changes from 500 to 860-Vdc for EV on-board chargers with the voltage range of 250–430-Vdc [17]–[19].”
Background
Metadata
- Authors
- Lu, J., Mallik, A., Zou, S., & Khaligh, A.
- Venue
- IEEE Transactions on Transportation Electrification
- Published
- 2018-03
- Volume
- 4
- Issue
- 1
- Pages
- 99-107
- ISSN
- 2332-7782 (ISSN-L)
- OpenAlex
- W2758178069
- Cited by
- 43
- References
- 4
- FWCI
- 1.68
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Variable DC-Link Control Loop Design for an Integrated Two-Stage AC/DC Converter. https://app.cochat.ai/papers/10.1109/tte.2017.2755772
- The paper
- Lu, J., Mallik, A., Zou, S., & Khaligh, A. (2018). Variable DC-Link Control Loop Design for an Integrated Two-Stage AC/DC Converter. IEEE Transactions on Transportation Electrification. https://doi.org/10.1109/tte.2017.2755772
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.