CoChat

High-Efficiency Module Design of Solid-State Transformers for Railway Vehicles

Lee, Eun S., Park, Jin H., Kim, Myung Y., Lee, June S. · 2022 · IEEE Transactions on Transportation Electrification

The DOI matches its Crossref record; 28 of the 28 references it cites were found in a registry or an index.

Abstract

The solid-state transformer (SST) can be a promising solution to replace the conventional 50- or 60-Hz main transformer (MTr) for railway vehicles. Unlike the existing SST technologies for stationary power applications, the SST applied to railway vehicles requires severe constraint of installation space and intensive management of heat dissipation. To optimally design the SST module applied to the railway vehicles, which is one of the major components in the whole SST system, the optimal magnetic component designs for high-efficiency and thermal stable operations in the confined installation space are proposed in this article. In order to meet the SST system requirements for ac 25-kV-to-dc 1.5-kV power conversion, an overall SST topology and its control schemes are established. Based on the proposed SST topology, considering the operating drive profile of the urban railway vehicles, the operating sequence of the proposed SST is introduced and verified by simulation. By virtue of the proposed magnetic component design, the optimal number of turns for the inductor and transformer in dual-active-bridge converters can be appropriately determined for 50-kV high-voltage insulation and high-efficiency operation when the installation space for the magnetic components is given. For targeting the 3.0-MW maximum power transfer capability of the proposed SST system, the 300-kW SST modules, operating at 500 Hz and 10 kHz for ac/dc converters and dc/dc converters, respectively, were fabricated and verified by experiment. By two experimental SST module sets, the static performance of the power converters in the SST module and the dynamic operating sequence has been successfully implemented. For the 300-kW full-load operation, 99.7% of power transfer efficiency for the proposed magnetic components and 97.2% of total power efficiency were obtained. As a result, the measured temperature characteristics for the proposed SST module, including the magnetic components, were managed below 125 °C under a severe experimental environment.

Overview

Integrity signals

Registry

Crossref · 10.1109/tte.2021.3101733

Cites

28 of 28 references verified0 citation errors · 0 not checkable

Statistics

Recomputing p-values needs the paper’s full text.

Verification

Claims the paper makes

This paper’s full text isn’t openly available, so its claims and self-check weren’t run. The registry and citation checks still apply.

Citations

Cites

Show all 28 references

Research works printed but not linked: 1

  1. Ferrite Core Datasheet

Cited by

See all 36

Metadata

Authors
Lee, E. S., Park, J. H., Kim, M. Y., & Lee, J. S.
Affiliations
  • Hanyang University (KR)
  • Korea Railroad Research Institute (KR)
  • Dankook University (KR)
Venue
IEEE Transactions on Transportation Electrification
Published
2022-03
Volume
8
Issue
1
Pages
98-120
ISSN
  • 2332-7782 (ISSN-L)
  • 2372-2088
OpenAlex
W3195409422
Cited by
36
References
28
Citations by year
2026: 8 · 2025: 6 · 2024: 8 · 2023: 5 · 2022: 8
FWCI
1.62
Type
journal article
Language
en
Open access
closed
Locations
IEEE Transactions on Transportation Electrification (publishedVersion)
Funders
Ministry of Land, Infrastructure and Transport (MOLIT) of the Korean Government through the Railroad Technology Development Program (21RSCD-C163337-01)
Topics
  • Physical Sciences › Engineering › Electrical and Electronic Engineering › Advanced DC-DC Converters
  • Physical Sciences › Engineering › Electrical and Electronic Engineering › Wireless Power Transfer Systems
  • Physical Sciences › Engineering › Electrical and Electronic Engineering › Multilevel Inverters and Converters
Keywords
solid-state transformer, railway rolling stock, magnetic component design, dual active bridge converter, high-voltage insulation, power conversion efficiency, thermal management, AC-DC converter, DC-DC converter, operating sequence, power transfer capability

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

How to cite

Cite CoChat for the checks on this page, and the paper for its own findings.

This page
CoChat. (2026). Citation check: High-Efficiency Module Design of Solid-State Transformers for Railway Vehicles. https://app.cochat.ai/papers/10.1109/tte.2021.3101733
The paper
Lee, E. S., Park, J. H., Kim, M. Y., & Lee, J. S. (2022). High-Efficiency Module Design of Solid-State Transformers for Railway Vehicles. IEEE Transactions on Transportation Electrification. https://doi.org/10.1109/tte.2021.3101733

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.