CoChat

A Reliable Method for Removing Fabry–Perot Effect in Material Characterization With Terahertz Time-Domain Spectroscopy

Liu, Dayou, Lu, Tianqi, Qi, Feng · 2020 · IEEE Transactions on Terahertz Science and Technology

The DOI matches its Crossref record; 21 of the 21 references it cites were found in a registry or an index.

Abstract

Terahertz Time-Domain Spectroscopy (THz-TDS) has been a powerful tool for material characterization. The Fabry-Perot (FP) effect caused by the multiple reflections within the sample exists inherently, which makes the echoes contaminated. In the case of thin samples, different reflection signals may merge together and even the echoes corresponding to the main reflection disappears, making the characterization improper or impossible. To deal with this problem, a novel time-domain optimization method is proposed for removing the FP effect. By introducing a new term which describes the variation of the waveform in time-domain, not only the complex refractive index but also the thickness of material are obtained for a very thin silicon wafer (~100 μm) whose thickness is less than 2/3 lambda at the central frequency of the THz-TDS system. The accuracy of the algorithm is quite comparable to an iterative method, which is considered to be the most accurate one at the moment, but it is more than 100 times faster, with a better convergence performance. Hence, it is promising for rapid material scenarios such as the in-line quality control and imaging-related applications.

Overview

Integrity signals

Registry

Crossref · 10.1109/tthz.2020.3001508

Cites

21 of 21 references verified0 citation errors · 0 not checkable

Statistics

Recomputing p-values needs the paper’s full text.

Verification

Claims the paper makes

This paper’s full text isn’t openly available, so its claims and self-check weren’t run. The registry and citation checks still apply.

Citations

Cites

Show all 21 references

Cited by

See all 27

Metadata

Authors
Liu, D., Lu, T., & Qi, F.
Affiliations
  • Shenyang Institute of Automation (CN)
  • State Grid Liaoning Electric Power Company (China) (CN)
Venue
IEEE Transactions on Terahertz Science and Technology
Published
2020-09
Volume
10
Issue
5
Pages
443-452
ISSN
  • 2156-342X (ISSN-L)
  • 2156-3446
OpenAlex
W3035112734
Cited by
27
References
21
Citations by year
2026: 3 · 2025: 6 · 2024: 8 · 2023: 5 · 2022: 3 · 2021: 2
FWCI
0.86
Type
journal article
Language
en
Open access
closed
Locations
  • IEEE Transactions on Terahertz Science and Technology (publishedVersion)
  • SIA OpenIR (Chinese Academy of Sciences) (submittedVersion)
Funders
  • Independent Project of Robotics and Intelligent Manufacturing Innovation Institute, Chinese Academy of Sciences (C2019001)
  • National Natural Science Foundation of China (61804160, 61801467)
Topics
  • Physical Sciences › Engineering › Electrical and Electronic Engineering › Terahertz technology and applications
  • Physical Sciences › Engineering › Electrical and Electronic Engineering › Microwave and Dielectric Measurement Techniques
  • Physical Sciences › Chemistry › Spectroscopy › Spectroscopy and Laser Applications
Keywords
Fabry-Perot effect, terahertz time-domain spectroscopy, multiple reflections, thin samples, silicon wafers, complex refractive index, thickness measurement, time-domain optimization, in-line quality control

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

How to cite

Cite CoChat for the checks on this page, and the paper for its own findings.

This page
CoChat. (2026). Citation check: A Reliable Method for Removing Fabry–Perot Effect in Material Characterization With Terahertz Time-Domain Spectroscopy. https://app.cochat.ai/papers/10.1109/tthz.2020.3001508
The paper
Liu, D., Lu, T., & Qi, F. (2020). A Reliable Method for Removing Fabry–Perot Effect in Material Characterization With Terahertz Time-Domain Spectroscopy. IEEE Transactions on Terahertz Science and Technology. https://doi.org/10.1109/tthz.2020.3001508

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.