Integration of 2D CMUT arrays with front-end electronics for volumetric ultrasound imaging
Open accessAbstract
For three-dimensional (3D) ultrasound imaging, connecting elements of a two-dimensional (2D) transducer array to the imaging system's front-end electronics is a challenge because of the large number of array elements and the small element size. To compactly connect the transducer array with electronics, we flip-chip bond a 2D 16 x 16-element capacitive micromachined ultrasonic transducer (CMUT) array to a custom-designed integrated circuit (IC). Through-wafer interconnects are used to connect the CMUT elements on the top side of the array with flip-chip bond pads on the back side. The IC provides a 25-V pulser and a transimpedance preamplifier to each element of the array. For each of three characterized devices, the element yield is excellent (99 to 100% of the elements are functional). Center frequencies range from 2.6 MHz to 5.1 MHz. For pulse echo operation, the average - 6-dB fractional bandwidth is as high as 125%. Transmit pressures normalized to the face of the transducer are as high as 339 kPa and input-referred receiver noise is typically 1.2 to 2.1 mPa/pHz. The flip-chip bonded devices were used to acquire 3D synthetic aperture images of a wire-target phantom. Combining the transducer array and IC, as shown in this paper, allows for better utilization of large arrays, improves receive sensitivity, and may lead to new imaging techniques that depend on transducer arrays that are closely coupled to IC electronics.
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cited by
Marzo, A., & Drinkwater, B. W. (2019) · Proceedings of the National Academy of Sciences · doi:10.1073/pnas.1813047115 · Cited by 526
Looking at sound: optoacoustics with all-optical ultrasound detection
Wissmeyer, G., Pleitez, M. A., Rosenthal, A., & Ntziachristos, V. (2018) · Light: Science & Applications · doi:10.1038/s41377-018-0036-7 · Cited by 374
Review of piezoelectric micromachined ultrasonic transducers and their applications
Jung, J., Lee, W., Kang, W., Shin, E., Ryu, J., & Choi, H. (2017) · Journal of Micromechanics and Microengineering · doi:10.1088/1361-6439/aa851b · Cited by 340
Capacitive micromachined ultrasonic transducers for medical imaging and therapy
Khuri-Yakub, B. T., & Oralkan, Ö. (2011) · Journal of Micromechanics and Microengineering · doi:10.1088/0960-1317/21/5/054004 · Cited by 332
Self-citationSingle-chip CMUT-on-CMOS front-end system for real-time volumetric IVUS and ICE imaging
Gurun, G., Tekes, C., Zahorian, J., Xu, T., Satir, S., Karaman, M., Hasler, J., & Degertekin, F. L. (2014) · IEEE Transactions on Ultrasonics, Ferroelectrics, and Frequency Control · doi:10.1109/tuffc.2014.6722610 · Cited by 176
Self-citation
Metadata
- Authors
- Wygant, I. O., Zhuang, X., Yeh, D. T., Oralkan, O., Ergun, A. S., Karaman, M., & Khuri-Yakub, B. T.
- Venue
- IEEE Transactions on Ultrasonics, Ferroelectrics and Frequency Control
- Published
- 2008-02
- Volume
- 55
- Issue
- 2
- Pages
- 327-342
- ISSN
- 0885-3010 (ISSN-L)
- OpenAlex
- W2157268614
- Cited by
- 248
- References
- 0
- FWCI
- 23.49
- Type
- journal article
- Language
- en
- Open access
- green
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Integration of 2D CMUT arrays with front-end electronics for volumetric ultrasound imaging. https://app.cochat.ai/papers/10.1109/tuffc.2008.652
- The paper
- Wygant, I. O., Zhuang, X., Yeh, D. T., Oralkan, O., Ergun, A. S., Karaman, M., & Khuri-Yakub, B. T. (2008). Integration of 2D CMUT arrays with front-end electronics for volumetric ultrasound imaging. IEEE Transactions on Ultrasonics, Ferroelectrics and Frequency Control. https://doi.org/10.1109/tuffc.2008.652
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.