High frame-rate blood vector velocity imaging using plane waves: Simulations and preliminary experiments
Abstract
Conventional ultrasound methods for acquiring color images of blood velocity are limited by a relatively low frame-rate and are restricted to give velocity estimates along the ultrasound beam direction only. To circumvent these limitations, the method presented in this paper uses 3 techniques: 1) The ultrasound is not focused during the transmissions of the ultrasound signals; 2) A 13-bit Barker code is transmitted simultaneously from each transducer element; and 3) The 2-D vector velocity of the blood is estimated using 2-D cross-correlation. A parameter study was performed using the Field II program, and performance of the method was investigated when a virtual blood vessel was scanned by a linear array transducer. An improved parameter set for the method was identified from the parameter study, and a flow rig measurement was performed using the same improved setup as in the simulations. Finally, the common carotid artery of a healthy male was scanned with a scan sequence that satisfies the limits set by the Food and Drug Administration. Vector velocity images were obtained with a frame-rate of 100 Hz where 40 speckle images are used for each vector velocity image. It was found that the blood flow approximately followed the vessel wall, and that maximum velocity was approximately 1 m/s, which is a normal value for a healthy person. To further evaluate the method, the test person was scanned with magnetic resonance (MR) angiography. The volume flow derived from the MR scanning was compared with that from the ultrasound scanning. A deviation of 9% between the 2 volume flow estimates was found.
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Introduction to Fourier Optics
Sutton, P. (1996) · Quantum and Semiclassical Optics: Journal of the European Optical Society Part B · doi:10.1088/1355-5111/8/5/014 · Cited by 4,934
Calculation of pressure fields from arbitrarily shaped, apodized, and excited ultrasound transducers
Jensen, J. A., & Svendsen, N. B. (1992) · IEEE Transactions on Ultrasonics, Ferroelectrics and Frequency Control · doi:10.1109/58.139123 · Cited by 2,493
Self-citationArray Signal Processing: Concepts and Techniques
Johnson, D. H., & Dudgeon, D. E. (1993) · Medical Entomology and Zoology · Cited by 1,940
Boone, K. G., & Holder, D. S. (1996) · Medical & Biological Engineering & Computing · doi:10.1007/bf02520003 · Cited by 1,919
A fundamental limit on delay estimation using partially correlated speckle signals
Walker, W. F., & Trahey, G. E. (1995) · IEEE Transactions on Ultrasonics, Ferroelectrics and Frequency Control · doi:10.1109/58.365243 · Cited by 479
A new method for estimation of velocity vectors
Jensen, J. A., & Munk, P. (1998) · IEEE Transactions on Ultrasonics, Ferroelectrics and Frequency Control · doi:10.1109/58.677749 · Cited by 428
Self-citationUltrafast compound imaging for 2-D motion vector estimation: application to transient elastography
Tanter, M., Bercoff, J., Sandrin, L., & Fink, M. (2002) · IEEE Transactions on Ultrasonics, Ferroelectrics and Frequency Control · doi:10.1109/tuffc.2002.1041078 · Cited by 414
Angle Independent Ultrasonic Detection of Blood Flow
Trahey, G. E., Allison, J. W., & von Ramm, O. T. (1987) · IEEE Transactions on Biomedical Engineering · doi:10.1109/tbme.1987.325938 · Cited by 386
Estimation of Blood Velocities Using Ultrasound: A Signal Processing Approach
Jensen, J. A. (1996) · Medical Entomology and Zoology · Cited by 343
Self-citationCoded excitation for diagnostic ultrasound: a system developer's perspective
Chiao, R. Y., & Hao, X. (2005) · IEEE Transactions on Ultrasonics, Ferroelectrics and Frequency Control · doi:10.1109/tuffc.2005.1406543 · Cited by 300
Doppler Ultrasound: Physics, Instrumentation and Clinical Applications
Ritenour, E. R. (1990) · Radiology · doi:10.1148/radiology.177.2.346 · Cited by 289
Cross-beam vector Doppler ultrasound for angle-independent velocity measurements
Dunmire, B., Beach, K. W., Labs, K.-H., Plett, M., & Strandness, D. E. (2000) · Ultrasound in Medicine & Biology · doi:10.1016/s0301-5629(00)00287-8 · Cited by 272
Coded excitation for diagnostic ultrasound: a system developer's perspective
Chiao, R. Y., & Hao, X. (2004) · IEEE Symposium on Ultrasonics, 2003 · doi:10.1109/ultsym.2003.1293440 · Cited by 270
2D and 3D high frame rate imaging with limited diffraction beams
Lu, J.-Y. (1997) · IEEE Transactions on Ultrasonics Ferroelectrics and Frequency Control · doi:10.1109/58.655200 · Cited by 258
Multiple crossed-beam ultrasound Doppler velocimetry
Fox, M. D. (1978) · IEEE Transactions on Sonics and Ultrasonics · doi:10.1109/t-su.1978.31028 · Cited by 172
Ultrasound Doppler Probing of Flows Transverse with Respect to Beam Axis
Newhouse, V. L., Censor, D., Vontz, T., Cisneros, J. A., & Goldberg, B. B. (1987) · IEEE Transactions on Biomedical Engineering · doi:10.1109/tbme.1987.325920 · Cited by 170
Lu, J.-Y., Cheng, J., & Wang, J. (2006) · IEEE Transactions on Ultrasonics Ferroelectrics and Frequency Control · doi:10.1109/tuffc.2006.112 · Cited by 98
Noninvasive simultaneous assessment of wall shear rate and wall distension in carotid arteries
Tortoli, P., Morganti, T., Bambi, G., Palombo, C., & Ramnarine, K. V. (2006) · Ultrasound in Medicine & Biology · doi:10.1016/j.ultrasmedbio.2006.07.023 · Cited by 80
Directional velocity estimation using focusing along the flow direction. I: theory and simulation
Jensen, J. A. (2003) · IEEE Transactions on Ultrasonics Ferroelectrics and Frequency Control · doi:10.1109/tuffc.2003.1214505 · Cited by 77
Self-citationExamples of In Vivo Blood Vector Velocity Estimation
Udesen, J., Nielsen, M. B., Nielsen, K. R., & Jensen, J. A. (2007) · Ultrasound in Medicine & Biology · doi:10.1016/j.ultrasmedbio.2006.10.014 · Cited by 76
Self-citation
Cited by
Ultrafast imaging in biomedical ultrasound
Tanter, M., & Fink, M. (2014) · IEEE Transactions on Ultrasonics, Ferroelectrics, and Frequency Control · doi:10.1109/tuffc.2014.2882 · Cited by 1,151
Ultrafast compound doppler imaging: providing full blood flow characterization
Bercoff, J., Montaldo, G., Loupas, T., Savery, D., Mézière, F., Fink, M., & Tanter, M. (2011) · IEEE Transactions on Ultrasonics, Ferroelectrics and Frequency Control · doi:10.1109/tuffc.2011.1780 · Cited by 510
3D ultrafast ultrasound imaging in vivo
Provost, J., Papadacci, C., Arango, J. E., Imbault, M., Fink, M., Gennisson, J.-L., Tanter, M., & Pernot, M. (2014) · Physics in Medicine and Biology · doi:10.1088/0031-9155/59/19/l1 · Cited by 356
Metadata
- Authors
- Udesen, J., Gran, F., Hansen, K., Jensen, J. A., Thomsen, C., & Nielsen, M. B.
- Venue
- IEEE Transactions on Ultrasonics, Ferroelectrics and Frequency Control
- Published
- 2008-08
- Volume
- 55
- Issue
- 8
- Pages
- 1729-1743
- ISSN
- 0885-3010 (ISSN-L)
- OpenAlex
- W2117134979
- Cited by
- 254
- References
- 20
- FWCI
- 5.50
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.