The DOI matches its Crossref record; 6 of the 6 references it cites were found in a registry or an index.
Phase Coherence Imaging
Abstract
A new method for grating and side lobes suppression in ultrasound images is presented. It is based on an analysis of the phase diversity at the aperture data. Two coherence factors, namely the phase coherence factor (PCF) and the sign coherence factor (SCF), are proposed to weight the coherent sum output. Different from other approaches, phase rather than amplitude information is used to perform the correction action. Besides achieving the main goal, the method obtains improvements in lateral resolution and SNR. Implementation of the SCF technique is quite straightforward, operating in realtime, and can be added to any virtually existing beamformer to improve the resolution, contrast, SNR, and dynamic range of the images. A programmable parameter allows adjusting the sensitivity of the method to out-of-phase signals, from zero to a strict coherence criterion. The theoretical basis for the 2 methods are given and their performances evaluated by simulation. Then, experiments are conducted to provide results that are in good agreement with those expected from theory and simulation.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
(1974) · IEEE Acoustics, Speech, and Signal Processing Newsletter · doi:10.1109/msp.1974.237438 · Cited by 1,339
Adaptive Beamforming Applied to Medical Ultrasound Imaging
Synnevag, J. F., Austeng, A., & Holm, S. (2007) · IEEE Transactions on Ultrasonics, Ferroelectrics and Frequency Control · doi:10.1109/tuffc.2007.431 · Cited by 592
Adaptive imaging using the generalized coherence factor
Li, P.-C., & Li, M.-L. (2003) · IEEE Transactions on Ultrasonics, Ferroelectrics and Frequency Control · doi:10.1109/tuffc.2003.1182117 · Cited by 514
Beam steering with pulsed two-dimensional transducer arrays
Turnbull, D. H., & Foster, F. S. (1991) · IEEE Transactions on Ultrasonics, Ferroelectrics and Frequency Control · doi:10.1109/58.84270 · Cited by 303
Coherence factor of speckle from a multi-row probe
Hollman, K. W., Rigby, K. W., & O'Donnell, M. (2003) · 1999 IEEE Ultrasonics Symposium. Proceedings. International Symposium (Cat. No.99CH37027) · doi:10.1109/ultsym.1999.849225 · Cited by 276
Ultrasparse, ultrawideband arrays
Schwartz, J. L., & Steinberg, B. D. (1998) · IEEE Transactions on Ultrasonics, Ferroelectrics and Frequency Control · doi:10.1109/58.660149 · Cited by 167
Cited by
Short-lag spatial coherence of backscattered echoes: imaging characteristics
Lediju, M. A., Trahey, G. E., Byram, B. C., & Dahl, J. J. (2011) · IEEE Transactions on Ultrasonics, Ferroelectrics and Frequency Control · doi:10.1109/tuffc.2011.1957 · Cited by 445
So you think you can DAS? A viewpoint on delay-and-sum beamforming
Perrot, V., Polichetti, M., Varray, F., & Garcia, D. (2021) · Ultrasonics · doi:10.1016/j.ultras.2020.106309 · Cited by 377
A survey on deep learning in medical ultrasound imaging
Song, K., Feng, J., & Chen, D. (2024) · Frontiers in Physics · doi:10.3389/fphy.2024.1398393 · Cited by 59
Metadata
- Authors
- Camacho, J., Parrilla, M., & Fritsch, C.
- Venue
- IEEE Transactions on Ultrasonics, Ferroelectrics and Frequency Control
- Published
- 2009-05
- Volume
- 56
- Issue
- 5
- Pages
- 958-974
- ISSN
- 0885-3010 (ISSN-L)
- OpenAlex
- W2132058266
- Cited by
- 525
- References
- 6
- FWCI
- 6.34
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.