The DOI matches its Crossref record; 1 of the 1 references it cites were found in a registry or an index.
Visualizing diffusion tensor mr images using streamtubes and streamsurfaces
Abstract
We present a new method for visualizing 3D volumetric diffusion tensor MR images. We distinguish between linear anisotropy and planar anisotropy and represent values in the two regimes using streamtubes and streamsurfaces, respectively. Streamtubes represent structures with primarily linear diffusion, typically fiber tracts; streamtube direction correlates with tract orientation. The cross-sectional shape and color of each streamtube represent additional information from the diffusion tensor at each point. Streamsurfaces represent structures in which diffusion is primarily planar. Our algorithm chooses a very small representative subset of the streamtubes and streamsurfaces for display. We describe the set of metrics used for the culling process, which reduces visual clutter and improves interactivity. We also generate anatomical landmarks to identify the locations of such structures as the eyes, skull surface, and ventricles. The final models are complex surface geometries that can be imported into many interactive graphics software environments. We describe a virtual environment to interact with these models. Expert feedback from doctors studying changes in white-matter structures after gamma-knife capsulotomy and preoperative planning for brain tumor surgery shows that streamtubes correlate well with major neural structures, the 2D section and geometric landmarks are important in understanding the visualization, and the stereo and interactivity from the virtual environment aid in understanding the complex geometric models.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Anisotropy in high angular resolution diffusion-weighted MRI
Frank, L. R. (2001) · Magnetic Resonance in Medicine · doi:10.1002/mrm.1125 · Cited by 389
Cited by
Virtual in vivo interactive dissection of white matter fasciculi in the human brain
Catani, M., Howard, R. J., Pajevic, S., & Jones, D. K. (2002) · NeuroImage · doi:10.1006/nimg.2002.1136 · Cited by 1,637
Virtual reality in behavioral neuroscience and beyond
Tarr, M. J., & Warren, W. H. (2002) · Nature Neuroscience · doi:10.1038/nn948 · Cited by 325
Virtual reality and the CAVE: Taxonomy, interaction challenges and research directions
Muhanna, M. A. (2015) · Journal of King Saud University - Computer and Information Sciences · doi:10.1016/j.jksuci.2014.03.023 · Cited by 284
Quantitative tractography metrics of white matter integrity in diffusion-tensor MRI
Correia, S., Lee, S. Y., Voorn, T., Tate, D. F., Paul, R. H., Zhang, S., Salloway, S. P., Malloy, P. F., & Laidlaw, D. H. (2008) · NeuroImage · doi:10.1016/j.neuroimage.2008.05.022 · Cited by 85
Self-citationKaufman, J. A., Ahrens, E. T., Laidlaw, D. H., Zhang, S., & Allman, J. M. (2005) · The Anatomical Record Part A: Discoveries in Molecular, Cellular, and Evolutionary Biology · doi:10.1002/ar.a.20264 · Cited by 54
Self-citationKernel regression estimation of fiber orientation mixtures in diffusion MRI
Cabeen, R. P., Bastin, M. E., & Laidlaw, D. H. (2016) · NeuroImage · doi:10.1016/j.neuroimage.2015.11.061 · Cited by 37
Self-citation
Metadata
- Authors
- Zhang, S., Demiralp, C., & Laidlaw, D. H.
- Venue
- IEEE Transactions on Visualization and Computer Graphics
- Published
- 2003-10
- Volume
- 9
- Issue
- 4
- Pages
- 454-462
- ISSN
- 1077-2626 (ISSN-L)
- OpenAlex
- W2135392761
- Cited by
- 204
- References
- 1
- FWCI
- 22.86
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.