Calibration of head-mounted displays for augmented reality applications
The DOI matches its Crossref record; 3 of the 3 references it cites were found in a registry or an index.
Abstract
The authors have developed "augmented reality" technology, consisting of a see-through head-mounted display, a robust, accurate position/orientation sensor, and their supporting electronics and software. Their primary goal is to apply this technology to touch labor manufacturing processes, enabling a factory worker to view index markings or instructions as if they were painted on the surface of a workpiece. In order to accurately project graphics onto specific points of a workpiece, it is necessary to have the coordinates of the workpiece, the display's virtual screen, the position sensor, and the user's eyes in the same coordinate system. The linear transformation and projection of each point to be displayed from world coordinates to virtual screen coordinates are described, and the experimental procedures for determining the correct values of the calibration parameters are characterized.>
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
A head-mounted three dimensional display
Sutherland, I. E. (1968) · Proceedings of the December 9-11, 1968, fall joint computer conference, part I on - AFIPS '68 (Fall, part I) · doi:10.1145/1476589.1476686 · Cited by 2,065
Augmented reality: an application of heads-up display technology to manual manufacturing processes
Caudell, T. P., & Mizell, D. W. (1992) · Proceedings of the Twenty-Fifth Hawaii International Conference on System Sciences · doi:10.1109/hicss.1992.183317 · Cited by 1,455
Self-citationA Computational Model for the Stereoscopic Optics of a Head-Mounted Display
Robinett, W., & Rolland, J. P. (1992) · Presence: Teleoperators and Virtual Environments · doi:10.1162/pres.1992.1.1.45 · Cited by 157
Cited by
Azuma, R. T. (1997) · Presence: Teleoperators and Virtual Environments · doi:10.1162/pres.1997.6.4.355 · Cited by 10,121
“Janin et al., 1993; Sims, 1994).”
BackgroundMethodInfluentialAugmented reality: a class of displays on the reality-virtuality continuum:
Milgram, P., Takemura, H., Utsumi, A., & Kishino, F. (1995) · SPIE Proceedings · doi:10.1117/12.197321 · Cited by 2,367
Feiner, S., MacIntyre, B., Höllerer, T., & Webster, A. (1997) · Personal Technologies · doi:10.1007/bf01682023 · Cited by 949
Improving static and dynamic registration in an optical see-through HMD
Azuma, R., & Bishop, G. (1994) · Proceedings of the 21st annual conference on Computer graphics and interactive techniques - SIGGRAPH '94 · doi:10.1145/192161.192199 · Cited by 390
Feiner, S., MacIntyre, B., Hollerer, T., & Webster, A. (2002) · Digest of Papers. First International Symposium on Wearable Computers · doi:10.1109/iswc.1997.629922 · Cited by 278
Metadata
- Authors
- Janin, A. L., Mizell, D. W., & Caudell, T. P.
- Venue
- Proceedings of IEEE Virtual Reality Annual International Symposium
- Publisher
- IEEE
- Published
- 2002-12-30
- Pages
- 246-255
- OpenAlex
- W2095952774
- Cited by
- 163
- References
- 3
- FWCI
- 5.43
- Type
- conference paper
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.