Ergonomics of exoskeletons: Objective performance metrics
The DOI matches its Crossref record; 3 of the 3 references it cites were found in a registry or an index.
Abstract
In this paper it is shown how variation of the kinematic structure of an exoskeleton and variation of its fixation strength on the human limb influences objective task performance metrics, such as interface load, tracking error and voluntary range of motion in a signal tracking experiment.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Development of NASA-TLX (Task Load Index): Results of Empirical and Theoretical Research
(1988) · Advances in Psychology · doi:10.1016/s0166-4115(08)62386-9 · Cited by 15,003
Development and Control of a ‘Soft-Actuated’ Exoskeleton for Use in Physiotherapy and Training
Tsagarakis, N. G., & Caldwell, D. G. (2003) · Autonomous Robots · doi:10.1023/a:1024484615192 · Cited by 335
Driven gait orthosis to do locomotor training of paraplegic patients
Colombo, G., Jorg, M., & Dietz, V. (2002) · Proceedings of the 22nd Annual International Conference of the IEEE Engineering in Medicine and Biology Society (Cat. No.00CH37143) · doi:10.1109/iembs.2000.901556 · Cited by 72
Cited by
Exoskeletons for industrial application and their potential effects on physical work load
de Looze, M. P., Bosch, T., Krause, F., Stadler, K. S., & O’Sullivan, L. W. (2016) · Ergonomics · doi:10.1080/00140139.2015.1081988 · Cited by 1,062
A biologically inspired soft exosuit for walking assistance
Asbeck, A. T., De Rossi, S. M. M., Holt, K. G., & Walsh, C. J. (2015) · The International Journal of Robotics Research · doi:10.1177/0278364914562476 · Cited by 450
“Specifically, Schiele (2009) reports that joint torques of up to 1.46 Nm can be created due to joint misalignments that occur as an exoskeleton moves relative to the wearer over time, even if it was initially aligned correctly.”
BackgroundInfluentialAssistance magnitude versus metabolic cost reductions for a tethered multiarticular soft exosuit
Quinlivan, B. T., Lee, S., Malcolm, P., Rossi, D. M., Grimmer, M., Siviy, C., Karavas, N., Wagner, D., Asbeck, A., Galiana, I., et al. (2017) · Science Robotics · doi:10.1126/scirobotics.aah4416 · Cited by 370
Stronger, Smarter, Softer: Next-Generation Wearable Robots
Asbeck, A. T., De Rossi, S. M. M., Galiana, I., Ding, Y., & Walsh, C. J. (2014) · IEEE Robotics & Automation Magazine · doi:10.1109/mra.2014.2360283 · Cited by 368
A lightweight soft exosuit for gait assistance
Wehner, M., Quinlivan, B., Aubin, P. M., Martinez-Villalpando, E., Baumann, M., Stirling, L., Holt, K., Wood, R., & Walsh, C. (2013) · 2013 IEEE International Conference on Robotics and Automation · doi:10.1109/icra.2013.6631046 · Cited by 361
“Previously, techniques such as tight straps or skin-adhesives were used to maintain the position of wearable devices, but experience has shown, that this quickly causes discomfort [16] [23, 24].”
Background
Metadata
- Authors
- Schiele, A.
- Venue
- World Haptics 2009 - Third Joint EuroHaptics conference and Symposium on Haptic Interfaces for Virtual Environment and Teleoperator Systems
- Publisher
- IEEE
- Published
- 2009
- Pages
- 103-108
- OpenAlex
- W2154630542
- Cited by
- 83
- References
- 3
- FWCI
- 2.78
- Type
- conference paper
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Ergonomics of exoskeletons: Objective performance metrics. https://app.cochat.ai/papers/10.1109/whc.2009.4810871
- The paper
- Schiele, A. (2009). Ergonomics of exoskeletons: Objective performance metrics. World Haptics 2009 - Third Joint EuroHaptics conference and Symposium on Haptic Interfaces for Virtual Environment and Teleoperator Systems. https://doi.org/10.1109/whc.2009.4810871
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.