CoChat

Vaginal degeneration following implantation of synthetic mesh with increased stiffness

Open access
Liang, R, Abramowitch, S, Knight, K, Palcsey, S, Nolfi, A, Feola, A, Stein, S, Moalli, PA · 2013 · BJOG: An International Journal of Obstetrics & Gynaecology
Cited by 164

The DOI matches its Crossref record; 3 of the 3 references it cites were found in a registry or an index.

Abstract

Objective: To compare the impact of the prototype prolapse mesh G ynemesh PS with that of two new‐generation lower stiffness meshes, U ltra P ro and S mart M esh, on vaginal morphology and structural composition. Design: A mechanistic study employing a nonhuman primate model. Setting: Magee‐Womens Research Institute at the University of P ittsburgh. Population: Parous rhesus macaques, with similar age, weight, parity and Pelvic Organ Prolapse‐Questionnaire scores. Methods: Following Institutional Animal Care Use Committee approval, 50 rhesus macaques were implanted with G ynemesh PS (n = 12), UltraPro with its blue line perpendicular to the longitudinal axis of vagina (n = 10), UltraPro with its blue line parallel to the longitudinal axis of vagina (n = 8) or SmartMesh (n = 8) via sacrocolpopexy following hysterectomy. Sham‐operated animals (n = 12) served as controls. Main outcome measures: The mesh–vagina complex was removed after 12 weeks and analysed for histomorphology, in situ cell apoptosis, total collagen, elastin, glycosaminoglycan content and total collagenase activity. Appropriate statistics and correlation analyses were performed accordingly. Results: Relative to sham and the two lower stiffness meshes, G ynemesh PS had the greatest negative impact on vaginal histomorphology and composition. Compared with sham, implantation with G ynemesh PS caused substantial thinning of the smooth muscle layer (1557 ± 499 μm versus 866 ± 210 μm, P = 0.02), increased apoptosis particularly in the area of the mesh fibres (P = 0.01), decreased collagen and elastin content (20%, P = 0.03 and 43%, P = 0.02, respectively) and increased total collagenase activity (135%, P = 0.01). Glycosaminoglycan, a marker of tissue injury, was highest with G ynemesh PS compared with sham and other meshes (P = 0.01). Conclusion: Mesh implantation with the stiffer mesh G ynemesh PS induced a maladaptive remodelling response consistent with vaginal degeneration.

Overview

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1111/1471-0528.12085

Cites

3 of 3 references verified0 citation errors · 0 not checkable

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cites

Show all 3 references

Cited by

See all 164

Metadata

Authors
Liang, R., Abramowitch, S., Knight, K., Palcsey, S., Nolfi, A., Feola, A., Stein, S., & Moalli, P.
Venue
BJOG: An International Journal of Obstetrics & Gynaecology
Publisher
Wiley
Published
2012-12-14
Volume
120
Issue
2
Pages
233-243
ISSN
  • 0306-5456 (ISSN-L)
  • 1470-0328
  • 1471-0528
OpenAlex
W2068943021
Cited by
164
References
3
FWCI
5.66
Type
journal article
Language
en
Open access
green

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

How to cite

Cite CoChat for the checks on this page, and the paper for its own findings.

This page
CoChat. (2026). Citation check: Vaginal degeneration following implantation of synthetic mesh with increased stiffness. https://app.cochat.ai/papers/10.1111/1471-0528.12085
The paper
Liang, R., Abramowitch, S., Knight, K., Palcsey, S., Nolfi, A., Feola, A., Stein, S., & Moalli, P. (2013). Vaginal degeneration following implantation of synthetic mesh with increased stiffness. BJOG: An International Journal of Obstetrics & Gynaecology. https://doi.org/10.1111/1471-0528.12085

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.