Background: Fetal macrosomia is associated with an increased risk of adverse maternal and neonatal outcomes. Objectives: To compare the accuracy of antenatal two‐dimensional (2D) ultrasound, three‐dimensional (3D) ultrasound, and magnetic resonance imaging (MRI) in predicting fetal macrosomia at birth. Search strategy: Medline (1966–2013), Embase, the Cochrane Library and Web of Knowledge. Selection criteria: Cohort or diagnostic accuracy studies of women with a singleton pregnancy, who had third‐trimester imaging to predict macrosomia (>4000 g, >4500 g or >90th or >95th centile). Data collection and analysis: Two reviewers screened studies, performed data extraction and assessed methodological quality. The bivariate model was used to obtain summary sensitivities, specificities and likelihood ratios. Main results: Fifty‐eight studies (34 367 pregnant women) were included. Most were poorly reported. Only one study assessed 3D ultrasound volumetry. For predicting birthweight >4000 g or >90th centile, the summary sensitivity for 2D ultrasound (Hadlock) estimated fetal weight (EFW) >90th centile or >4000 g (29 studies) was 0.56 (95% CI 0.49–0.61), 2D ultrasound abdominal circumference (AC) >35 cm (four studies) was 0.80 (95% confidence interval [95% CI] 0.69–0.87) and MRI EFW (three studies) was 0.93 (95% CI 0.76–0.98). The summary specificities were 0.92 (95% CI 0.90–0.94), 0.86 (95% CI 0.74–0.93) and 0.95 (95% CI 0.92–0.97), respectively. Conclusion: There is insufficient evidence to conclude that MRI EFW is more sensitive than 2D ultrasound AC (which is more sensitive than 2D EFW); although it was more specific. Further primary research is required before recommending MRI EFW for use in clinical practice. Tweetable abstract: Systematic review of antenatal imaging to predict macrosomia. MRI EFW is more sensitive than ultrasound EFW.

Overview

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1111/1471-0528.13517

Cites

9 of 9 references verified0 citation errors · 0 not checkable

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cites

Show all 9 references

Cited by

See all 87

Metadata

Authors
Malin, G., Bugg, G., Takwoingi, Y., Thornton, J., & Jones, N.
Venue
BJOG: An International Journal of Obstetrics & Gynaecology
Publisher
Wiley
Published
2015-07-29
Volume
123
Issue
1
Pages
77-88
ISSN
  • 0306-5456 (ISSN-L)
  • 1470-0328
  • 1471-0528
OpenAlex
W1491060753
Cited by
87
References
9
FWCI
1.42
Type
journal article
Language
en
Open access
bronze

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

How to cite

Cite CoChat for the checks on this page, and the paper for its own findings.

This page
CoChat. (2026). Citation check: Antenatal magnetic resonance imaging versus ultrasound for predicting neonatal macrosomia: a systematic review and meta‐analysis. https://app.cochat.ai/papers/10.1111/1471-0528.13517
The paper
Malin, G., Bugg, G., Takwoingi, Y., Thornton, J., & Jones, N. (2016). Antenatal magnetic resonance imaging versus ultrasound for predicting neonatal macrosomia: a systematic review and meta‐analysis. BJOG: An International Journal of Obstetrics & Gynaecology. https://doi.org/10.1111/1471-0528.13517

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.