Antenatal magnetic resonance imaging versus ultrasound for predicting neonatal macrosomia: a systematic review and meta‐analysis
Open accessThe DOI matches its Crossref record; 9 of the 9 references it cites were found in a registry or an index.
Abstract
Background: Fetal macrosomia is associated with an increased risk of adverse maternal and neonatal outcomes. Objectives: To compare the accuracy of antenatal two‐dimensional (2D) ultrasound, three‐dimensional (3D) ultrasound, and magnetic resonance imaging (MRI) in predicting fetal macrosomia at birth. Search strategy: Medline (1966–2013), Embase, the Cochrane Library and Web of Knowledge. Selection criteria: Cohort or diagnostic accuracy studies of women with a singleton pregnancy, who had third‐trimester imaging to predict macrosomia (>4000 g, >4500 g or >90th or >95th centile). Data collection and analysis: Two reviewers screened studies, performed data extraction and assessed methodological quality. The bivariate model was used to obtain summary sensitivities, specificities and likelihood ratios. Main results: Fifty‐eight studies (34 367 pregnant women) were included. Most were poorly reported. Only one study assessed 3D ultrasound volumetry. For predicting birthweight >4000 g or >90th centile, the summary sensitivity for 2D ultrasound (Hadlock) estimated fetal weight (EFW) >90th centile or >4000 g (29 studies) was 0.56 (95% CI 0.49–0.61), 2D ultrasound abdominal circumference (AC) >35 cm (four studies) was 0.80 (95% confidence interval [95% CI] 0.69–0.87) and MRI EFW (three studies) was 0.93 (95% CI 0.76–0.98). The summary specificities were 0.92 (95% CI 0.90–0.94), 0.86 (95% CI 0.74–0.93) and 0.95 (95% CI 0.92–0.97), respectively. Conclusion: There is insufficient evidence to conclude that MRI EFW is more sensitive than 2D ultrasound AC (which is more sensitive than 2D EFW); although it was more specific. Further primary research is required before recommending MRI EFW for use in clinical practice. Tweetable abstract: Systematic review of antenatal imaging to predict macrosomia. MRI EFW is more sensitive than ultrasound EFW.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
QUADAS-2: a revised tool for the quality assessment of diagnostic accuracy studies
Whiting, P. F., Rutjes, A. W. S., Westwood, M. E., Mallett, S., Deeks, J. J., Reitsma, J. B., Leeflang, M. M. G., Sterne, J. A. C., Bossuyt, P. M. M., & the QUADAS-2 Group* (2011) · Annals of Internal Medicine · doi:10.7326/0003-4819-155-8-201110180-00009 · Cited by 14,199
Reitsma, J. B., Glas, A. S., Rutjes, A. W. S., Scholten, R. J. P. M., Bossuyt, P. M., & Zwinderman, A. H. (2005) · Journal of Clinical Epidemiology · doi:10.1016/j.jclinepi.2005.02.022 · Cited by 3,369
Deeks, J. J., Macaskill, P., & Irwig, L. (2005) · Journal of Clinical Epidemiology · doi:10.1016/j.jclinepi.2005.01.016 · Cited by 2,910
Interpretation of random effects meta-analyses
Riley, R. D., Higgins, J. P. T., & Deeks, J. J. (2011) · BMJ · doi:10.1136/bmj.d549 · Cited by 2,884
Estimation of fetal weight with the use of head, body, and femur measurements—A prospective study
Hadlock, F. P., Harrist, R. B., Sharman, R. S., Deter, R. L., & Park, S. K. (1985) · American Journal of Obstetrics and Gynecology · doi:10.1016/0002-9378(85)90298-4 · Cited by 2,682
Empirical evidence of design-related bias in studies of diagnostic tests.
Lijmer, J. G. (1999) · JAMA · doi:10.1001/jama.282.11.1061 · Cited by 1,861
In utero analysis of fetal growth: a sonographic weight standard
Hadlock, F. P., Harrist, R. B., & Martinez-Poyer, J. (1991) · Radiology · doi:10.1148/radiology.181.1.1887021 · Cited by 1,281
Cochrane Handbook for Systematic Reviews of Diagnostic Test Accuracy
(2023) · doi:10.1002/9781119756194 · Cited by 757
Self-citationEmpirical evidence of the importance of comparative studies of diagnostic test accuracy
Takwoingi, Y., Leeflang, M. M. G., & Deeks, J. J. (2013) · Annals of Internal Medicine · doi:10.7326/0003-4819-158-7-201304020-00006 · Cited by 187
Self-citation
Cited by
Practice Bulletin No. 183: postpartum hemorrhage
(2017) · Obstetrics & Gynecology · doi:10.1097/aog.0000000000002351 · Cited by 1,406
Salameh, J.-P., Bossuyt, P. M., McGrath, T. A., Thombs, B. D., Hyde, C. J., Macaskill, P., Deeks, J. J., Leeflang, M., Korevaar, D. A., Whiting, P., et al. (2020) · BMJ · doi:10.1136/bmj.m2632 · Cited by 719
Self-citationISUOG Practice Guidelines: ultrasound assessment of fetal biometry and growth
Salomon, L. J., Alfirevic, Z., Da Silva Costa, F., Deter, R. L., Figueras, F., Ghi, T., Glanc, P., Khalil, A., Lee, W., Napolitano, R., et al. (2019) · Ultrasound in Obstetrics & Gynecology · doi:10.1002/uog.20272 · Cited by 704
Macrosomia: ACOG Practice Bulletin, Number 216
(2020) · Obstetrics & Gynecology · doi:10.1097/aog.0000000000003606 · Cited by 331
Metadata
- Authors
- Malin, G., Bugg, G., Takwoingi, Y., Thornton, J., & Jones, N.
- Venue
- BJOG: An International Journal of Obstetrics & Gynaecology
- Publisher
- Wiley
- Published
- 2015-07-29
- Volume
- 123
- Issue
- 1
- Pages
- 77-88
- ISSN
- 0306-5456 (ISSN-L)
- 1470-0328
- 1471-0528
- OpenAlex
- W1491060753
- Cited by
- 87
- References
- 9
- FWCI
- 1.42
- Type
- journal article
- Language
- en
- Open access
- bronze
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Antenatal magnetic resonance imaging versus ultrasound for predicting neonatal macrosomia: a systematic review and meta‐analysis. https://app.cochat.ai/papers/10.1111/1471-0528.13517
- The paper
- Malin, G., Bugg, G., Takwoingi, Y., Thornton, J., & Jones, N. (2016). Antenatal magnetic resonance imaging versus ultrasound for predicting neonatal macrosomia: a systematic review and meta‐analysis. BJOG: An International Journal of Obstetrics & Gynaecology. https://doi.org/10.1111/1471-0528.13517
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.