The DOI matches its Crossref record; 78 of the 78 references it cites were found in a registry or an index.
Difficult Airway Society guidelines for the management of tracheal extubation
Abstract
We read with concern the letter from Ms Ogilvie 1 in reaction to the recently published extubation guidelines by the Difficult Airway Society (DAS) 2. Ogilvie, representing Cook Medical (Limerick, Ireland), manufacturers of the Cook Airway Exchange Catheter (AEC), indicated that this device “is not intended to remain in the airway…for an extended period of time…” following extubation of a difficult airway. One of us (RMC) was involved in the development of the AEC, and this is precisely how he had intended that it be used. Our ability to predict successfully those patients who will tolerate extubation is far from perfect. Comparing patients with difficult airways whose tracheas were re-intubated with or without an AEC, Mort demonstrated that the AEC was associated with a very significant improvement in the first attempt success rate, the time required to complete re-intubation, and a reduction in severe hypoxia as well as bradycardia 3. Only 21/51 (41%) of the re-intubations involving an AEC took place within 2 h of extubation while 30/51 (59%) occurred between 2 h and 10 h. Thus, the major safety advantages of extubation over a tube exchanger are likely to be missed if the device is used exclusively to perform an exchange or if it is removed shortly following extubation of the difficult airway. The undersigned, representing DAS and the Society for Airway Management, strongly reaffirm the recommendations of the DAS guidelines and discourage the premature removal of tube exchangers until the probability of a required re-intubation seems very remote.
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Saving Mothers’ Lives: Reviewing maternal deaths to make motherhood safer: 2006–2008
(2011) · BJOG: An International Journal of Obstetrics & Gynaecology · doi:10.1111/j.1471-0528.2010.02847.x · Cited by 2,994
Updated by the Committee on Standards and Practice Parameters, Apfelbaum, J. L., Hagberg, C. A., Caplan, R. A., Blitt, C. D., Connis, R. T., Nickinovich, D. G., Hagberg, C. A., The previous update was developed by the American Society of Anesthesiologists Task Force on Difficult Airway Management, Caplan, R. A., et al. (2013) · Anesthesiology · doi:10.1097/aln.0b013e31827773b2 · Cited by 2,559
Self-citationClinical guidelines: Potential benefits, limitations, and harms of clinical guidelines
Woolf, S. H., Grol, R., Hutchinson, A., Eccles, M., & Grimshaw, J. (1999) · BMJ · doi:10.1136/bmj.318.7182.527 · Cited by 2,548
Cook, T. M., Woodall, N., & Frerk, C. (2011) · British Journal of Anaesthesia · doi:10.1093/bja/aer058 · Cited by 2,415
Turiel, E. (2007) · Handbook of Child Psychology · doi:10.1002/9780470147658.chpsy0313 · Cited by 2,143
Cummings Otolaryngology: Head and Neck Surgery
Flint, E. B. P. W., Haughey, B. H., Lund, V. J., Niparko, J. K., Robbins, K. T., Thomas, J. R., & Lesperance, M. M. (2004) · Cited by 1,439
On error management: lessons from aviation
Helmreich, R. L. (2000) · BMJ · doi:10.1136/bmj.320.7237.781 · Cited by 1,327
(2006) · Anesthesiology · doi:10.1097/00000542-200605000-00026 · Cited by 1,188
Cook, T. M., Woodall, N., Harper, J., & Benger, J. (2011) · British Journal of Anaesthesia · doi:10.1093/bja/aer059 · Cited by 1,065
Difficult Airway Society guidelines for management of the unanticipated difficult intubation
Henderson, J. J., Popat, M. T., Latto, I. P., & Pearce, A. C. (2004) · Anaesthesia · doi:10.1111/j.1365-2044.2004.03831.x · Cited by 1,025
Self-citation
Cited by
Frerk, C., Mitchell, V. S., McNarry, A. F., Mendonca, C., Bhagrath, R., Patel, A., O’Sullivan, E. P., Woodall, N. M., & Ahmad, I. (2015) · British Journal of Anaesthesia · doi:10.1093/bja/aev371 · Cited by 2,214
Self-citationGuidelines for the management of tracheal intubation in critically ill adults
Higgs, A., McGrath, B. A., Goddard, C., Rangasami, J., Suntharalingam, G., Gale, R., & Cook, T. M. (2018) · British Journal of Anaesthesia · doi:10.1016/j.bja.2017.10.021 · Cited by 900
Mushambi, M. C., Kinsella, S. M., Popat, M., Swales, H., Ramaswamy, K. K., Winton, A. L., & Quinn, A. C. (2015) · Anaesthesia · doi:10.1111/anae.13260 · Cited by 608
Self-citationDifficult Airway Society guidelines for awake tracheal intubation (ATI) in adults
Ahmad, I., El‐Boghdadly, K., Bhagrath, R., Hodzovic, I., McNarry, A. F., Mir, F., O'Sullivan, E. P., Patel, A., Stacey, M., & Vaughan, D. (2020) · Anaesthesia · doi:10.1111/anae.14904 · Cited by 563
Self-citationPandit, J. J., Andrade, J., Bogod, D. G., Hitchman, J. M., Jonker, W. R., Lucas, N., Mackay, J. H., Nimmo, A. F., O'Connor, K., O'Sullivan, E. P., et al. (2014) · British Journal of Anaesthesia · doi:10.1093/bja/aeu313 · Cited by 550
Self-citation
Metadata
- Authors
- Cooper, R. M., O'Sullivan, E., Popat, M., Behringer, E., & Hagberg, C. A.
- Venue
- Anaesthesia
- Publisher
- Wiley
- Published
- 2013-01-09
- Volume
- 68
- Issue
- 2
- Pages
- 217-217
- ISSN
- 0003-2409 (ISSN-L)
- 1365-2044
- OpenAlex
- W1603607406
- Cited by
- 336
- References
- 78
- FWCI
- 44.75
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Difficult Airway Society guidelines for the management of tracheal extubation. https://app.cochat.ai/papers/10.1111/anae.12139
- The paper
- Cooper, R. M., O'Sullivan, E., Popat, M., Behringer, E., & Hagberg, C. A. (2013). Difficult Airway Society guidelines for the management of tracheal extubation. Anaesthesia. https://doi.org/10.1111/anae.12139
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.