CoChat

Accuracy of tympanic and forehead thermometers in private paediatric practice

Teller, J, Ragazzi, M, Simonetti, GD, Lava, SAG · 2014 · Acta Paediatrica
Cited by 42

The DOI matches its Crossref record; 1 of the 1 references it cites were found in a registry or an index.

Abstract

Aim: To compare infrared tympanic and infrared contact forehead thermometer measurements with traditional rectal digital thermometers. Methods: A total of 254 children (137 girls) aged one to 24 months (median 7 months) consulting a private paediatric practice because of fever were prospectively recruited. Body temperature was measured using the three different devices. Results: The median and interquartile range for rectal, tympanic and forehead thermometers were 37.6 (37.1–38.4)°C, 37.5 (37.0–38.1)°C and 37.5 (37.1–37.9)°C, respectively (p < 0.01). The limits of agreement in the B land‐A ltman plots were −0.73 to +1.04°C for the tympanic thermometer and −1.18 to +1.64°C for the forehead thermometer. The specificity of both the tympanic and forehead thermometers for detecting fever above 38°C was good, but sensitivity was low. Forehead measurements were susceptible to the use of a radiant warmer. Conclusion: Both the tympanic and forehead devices recorded lower temperatures than the rectal thermometers. The limits of agreement were particularly wide for the forehead thermometer and considerable for the tympanic thermometer. In the absence of valid alternatives, because of the ease to use and little degree of discomfort, tympanic thermometers can still be used with some reservations. Forehead thermometers should not be used in paediatric practice.

Overview

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1111/apa.12464

Cites

1 of 1 references verified0 citation errors · 0 not checkable

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cites

Show all 1 references

Research works printed but not linked: 19

  1. Diethelm M, 1986, Prospektive Studie über die Tätigkeit des praktizierenden Kinderarztes – II. Besuchsgründe und Diagnosen, Helv Paediatr Acta, 41, 29
  2. 10.1016/j.clinthera.2009.08.006 · DOI
  3. 10.1136/adc.2010.185801 · DOI · Paper page
  4. 10.1016/S0140-6736(02)09783-0 · DOI · Paper page
  5. Freed GL, 1992, Lack of agreement of tympanic membrane temperature assessments with conventional methods in a private practice setting, Pediatrics, 89, 384, 10.1542/peds.89.3.384 · doi:10.1542/peds.89.3.384
  6. 10.1136/adc.2006.114314 · DOI
  7. 10.1111/j.1365-2702.2010.03565.x · DOI · Paper page
  8. 10.1016/S0733-8627(03)00051-8 · doi:10.1016/s0733-8627(03)00051-8
  9. 10.1097/ALN.0b013e31823d7784 · DOI · Paper page
  10. 10.1016/j.aenj.2008.05.003 · DOI
  11. 10.1111/j.1742-6723.2006.00847.x · DOI
  12. 10.1016/S0196-0644(95)70350-0 · DOI
  13. Fadzil FM, 2010, A comparative study on the accuracy of noninvasive thermometers, Aust Fam Physician, 39, 237
  14. 10.1001/archpedi.1996.02170260078013 · DOI
  15. 10.1186/1824-7288-37-8 · DOI
  16. 10.1016/j.clinthera.2012.06.011 · DOI
  17. 10.1097/PEC.0b013e31827b5427 · DOI · Paper page
  18. 10.1111/j.1365-2125.2012.04311.x · DOI
  19. 10.1016/S0022-3476(70)80281-5 · doi:10.1016/s0022-3476(70)80281-5

Cited by

See all 42

Metadata

Authors
Teller, J., Ragazzi, M., Simonetti, G., & Lava, S.
Venue
Acta Paediatrica
Publisher
Wiley
Published
2013-11-18
Volume
103
Issue
2
Pages
e80-3
ISSN
  • 0365-1436 (ISSN-L)
  • 0803-5253
  • 1651-2227
OpenAlex
W2019780896
Cited by
42
References
1
FWCI
2.19
Type
journal article
Language
en
Open access
closed

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

How to cite

Cite CoChat for the checks on this page, and the paper for its own findings.

This page
CoChat. (2026). Citation check: Accuracy of tympanic and forehead thermometers in private paediatric practice. https://app.cochat.ai/papers/10.1111/apa.12464
The paper
Teller, J., Ragazzi, M., Simonetti, G., & Lava, S. (2014). Accuracy of tympanic and forehead thermometers in private paediatric practice. Acta Paediatrica. https://doi.org/10.1111/apa.12464

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.