Allergic contact dermatitis caused by glucose sensors in type 1 diabetes patients
The DOI matches its Crossref record; 2 of the 2 references it cites were found in a registry or an index.
Abstract
Background: Allergic contact dermatitis caused by glucose sensors has become an increasing problem. Contact allergies to isobornyl acrylate, colophonium, ethyl cyanoacrylate and N,N‐dimethylacrylamide have been reported. However, there is a paucity of information regarding the prevalence of sensor‐related dermatitis and detailed patient histories. Objectives: To evaluate diabetes patients who have developed allergic contact dermatitis caused by glucose sensors. Patients and methods: Seventy patients with suspected contact allergy to glucose sensors referred to university hospital dermatology clinics in southern Finland were patch tested with the baseline series, an isobornyl acrylate dilution series, and a number of other acrylates. Atopic constitution, contact allergies, the severity of the dermatitis and the ability to continue with the same or another type of sensor were recorded. Results: Positive patch test reactions to isobornyl acrylate were seen in 51 of 63 (81%) Freestyle Libre users. Colophonium or its derivatives gave positive reactions in five of seven Medtronic Enlite users. The median duration of sensor use before dermatitis was 6 months. The estimated prevalences of contact allergy to sensor adhesives were 0.7% for Freestyle Libre and 0.8% for Enlite. Conclusions: We suggest that patients who have difficulties in finding a tolerable glucose sensor or an insulin pump should be patch tested.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Herman, A., Aerts, O., Baeck, M., Bruze, M., De Block, C., Goossens, A., Hamnerius, N., Huygens, S., Maiter, D., Tennstedt, D., et al. (2017) · Contact Dermatitis · doi:10.1111/cod.12866 · Cited by 192
Berg, A. K., Nørgaard, K., Thyssen, J. P., Zachariae, C., Hommel, E., Rytter, K., & Svensson, J. (2018) · Diabetes Technology & Therapeutics · doi:10.1089/dia.2018.0088 · Cited by 87 · cited 1×
“In contrast, 35% and 46% of glucose sensor users in Denmark have been reported to have skin problems related to their sensors.(15,16) However, not all of the findings were eczematous lesions, and the patients were not tested for contact allergies.”
Background
Cited by
7. Diabetes Technology: Standards of Medical Care in Diabetes—2022
American Diabetes Association Professional Practice Committee (2022) · Diabetes Care · doi:10.2337/dc22-s007 · Cited by 358
7. Diabetes Technology: Standards of Care in Diabetes—2025
American Diabetes Association Professional Practice Committee, ElSayed, N. A., McCoy, R. G., Aleppo, G., Balapattabi, K., Beverly, E. A., Briggs Early, K., Bruemmer, D., Echouffo-Tcheugui, J. B., Ekhlaspour, L., et al. (2025) · Diabetes Care · doi:10.2337/dc25-s007 · Cited by 348
7. Diabetes Technology: Standards of Care in Diabetes — 2023
ElSayed, N. A., Aleppo, G., Aroda, V. R., Bannuru, R. R., Brown, F. M., Bruemmer, D., Collins, B. S., Hilliard, M. E., Isaacs, D., Johnson, E. L., et al. (2023) · Diabetes Care · doi:10.2337/dc23-s007 · Cited by 301
7. Diabetes Technology: Standards of Care in Diabetes—2024
American Diabetes Association Professional Practice Committee, ElSayed, N. A., Aleppo, G., Bannuru, R. R., Bruemmer, D., Collins, B. S., Ekhlaspour, L., Hilliard, M. E., Johnson, E. L., Khunti, K., et al. (2024) · Diabetes Care · doi:10.2337/dc24-s007 · Cited by 281
Charleer, S., De Block, C., Van Huffel, L., Broos, B., Fieuws, S., Nobels, F., Mathieu, C., & Gillard, P. (2020) · Diabetes Care · doi:10.2337/dc19-1610 · Cited by 261
7. Diabetes Technology: Standards of Medical Care in Diabetes—2021
American Diabetes Association (2021) · Diabetes Care · doi:10.2337/dc21-s007 · Cited by 202
“Patch testing can be done to identify the cause of the contact dermatitis in some cases (101).”
BackgroundVisser, M. M., Charleer, S., Fieuws, S., De Block, C., Hilbrands, R., Van Huffel, L., Maes, T., Vanhaverbeke, G., Dirinck, E., Myngheer, N., et al. (2021) · The Lancet · doi:10.1016/s0140-6736(21)00789-3 · Cited by 165
Sherr, J. L., Heinemann, L., Fleming, G. A., Bergenstal, R. M., Bruttomesso, D., Hanaire, H., Holl, R. W., Petrie, J. R., Peters, A. L., & Evans, M. (2022) · Diabetes Care · doi:10.2337/dci22-0018 · Cited by 136
“Patch testing can be done in some cases to identify the cause of contact dermatitis [81].”
BackgroundFröhlich‐Reiterer, E., Elbarbary, N. S., Simmons, K., Buckingham, B., Humayun, K. N., Johannsen, J., Holl, R. W., Betz, S., & Mahmud, F. H. (2022) · Pediatric Diabetes · doi:10.1111/pedi.13445 · Cited by 74
Rigo, R. S., Levin, L. E., Belsito, D. V., Garzon, M. C., Gandica, R., & Williams, K. M. (2021) · Journal of Diabetes Science and Technology · doi:10.1177/1932296820918894 · Cited by 58
Herman, A., de Montjoye, L., & Baeck, M. (2020) · Contact Dermatitis · doi:10.1111/cod.13529 · Cited by 36
Metadata
- Authors
- Hyry, H. S. I., Liippo, J. P., & Virtanen, H. M.
- Venue
- Contact Dermatitis
- Publisher
- Wiley
- Published
- 2019-07-10
- Volume
- 81
- Issue
- 3
- Pages
- 161-166
- ISSN
- 0105-1873 (ISSN-L)
- 1600-0536
- OpenAlex
- W2950874258
- Cited by
- 86
- References
- 2
- FWCI
- 12.55
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.