Characterizing the reproducibility in using a liver microphysiological system for assaying drug toxicity, metabolism, and accumulation
Open accessThe DOI matches its Crossref record; 9 of the 9 references it cites were found in a registry or an index.
Abstract
Liver microphysiological systems (MPSs) are promising models for predicting hepatic drug effects. Yet, after a decade since their introduction, MPSs are not routinely used in drug development due to lack of criteria for ensuring reproducibility of results. We characterized the feasibility of a liver MPS to yield reproducible outcomes of experiments assaying drug toxicity, metabolism, and intracellular accumulation. The ability of the liver MPS to reproduce hepatotoxic effects was assessed using trovafloxacin, which increased lactate dehydrogenase (LDH) release and reduced cytochrome P450 3A4 (CYP3A4) activity. These observations were made in two test sites and with different batches of Kupffer cells. Upon culturing equivalent hepatocytes in the MPS, spheroids, and sandwich cultures, differences between culture formats were detected in CYP3A4 activity and albumin production. Cells in all culture formats exhibited different sensitivities to hepatotoxicant exposure. Hepatocytes in the MPS were more functionally stable than those of other culture platforms, as CYP3A4 activity and albumin secretion remained prominent for greater than 18 days in culture, whereas functional decline occurred earlier in spheroids (12 days) and sandwich cultures (7 days). The MPS was also demonstrated to be suitable for metabolism studies, where CYP3A4 activity, troglitazone metabolites, diclofenac clearance, and intracellular accumulation of chloroquine were quantified. To ensure reproducibility between studies with the MPS, the combined use of LDH and CYP3A4 assays were implemented as quality control metrics. Overall results indicated that the liver MPS can be used reproducibly in general drug evaluation applications. Study outcomes led to general considerations and recommendations for using liver MPSs. Study Highlights: WHAT IS THE CURRENT KNOWLEDGE ON THE TOPIC? Microphysiological systems (MPSs) have been designed to recreate organ‐ or tissue‐specific characteristics of extracellular microenvironments that enhance the physiological relevance of cells in culture. Liver MPSs enable long‐lasting and stable culture of hepatic cells by culturing them in three‐dimensions and exposing them to fluid flow. WHAT QUESTION DID THIS STUDY ADDRESS? What is the functional performance relative to other cell culture platforms and the reproducibility of a liver MPS for assessing drug development and evaluation questions, such as toxicity, metabolism, and pharmacokinetics? WHAT DOES THIS STUDY ADD TO OUR KNOWLEDGE? The liver MPS systematically detected the toxicity of trovafloxacin. When compared with spheroids and sandwich cultures, this system had a more stable function and different sensitivity to troglitazone, tamoxifen, and digoxin. Quantifying phase II metabolism of troglitazone and intracellular accumulation of chloroquine demonstrated the potential use of the liver MPS for studying drug metabolism and pharmacokinetics. Quality control criteria for assessing chip function were key for reliably using the liver MPS. HOW MIGHT THIS CHANGE CLINICAL PHARMACOLOGY OR TRANSLATIONAL SCIENCE? Due to its functional robustness and physiological relevance (3D culture, cells expose to fluid flow and co‐culture of different cell types), the liver MPS can, in a reproducible manner: (i) detect inflammatory‐induced drug toxicity, as demonstrated with trovafloxacin, (ii) detect the toxicity of other drugs, such as troglitazone, tamoxifen, and digoxin, with different effects than those detected in spheroids and sandwich cultures, (iii) enable studies of hepatic function that rely on prolonged cellular activity, and (iv) detect phase II metabolites and drug accumulation to potentially support the interpretation of clinical data. The integration of MPSs in drug development will be facilitated by careful evaluation of performance and reproducibility as performed in this study.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Bell, C. C., Hendriks, D. F. G., Moro, S. M. L., Ellis, E., Walsh, J., Renblom, A., Fredriksson Puigvert, L., Dankers, A. C. A., Jacobs, F., Snoeys, J., et al. (2016) · Scientific Reports · doi:10.1038/srep25187 · Cited by 739
Reproducing human and cross-species drug toxicities using a liver-chip
Jang, K.-J., Otieno, M. A., Ronxhi, J., Lim, H.-K., Ewart, L., Kodella, K. R., Petropolis, D. B., Kulkarni, G., Rubins, J. E., Conegliano, D., et al. (2019) · Science Translational Medicine · doi:10.1126/scitranslmed.aax5516 · Cited by 511
Treyer, A., & Müsch, A. (2013) · Comprehensive Physiology · doi:10.1002/cphy.c120009 · Cited by 252
3D microfluidic liver cultures as a physiological preclinical tool for hepatitis B virus infection
Ortega-Prieto, A. M., Skelton, J. K., Wai, S. N., Large, E., Lussignol, M., Vizcay-Barrena, G., Hughes, D., Fleck, R. A., Thursz, M., Catanese, M. T., et al. (2018) · Nature Communications · doi:10.1038/s41467-018-02969-8 · Cited by 236
Self-citationTsamandouras, N., Chen, W. L. K., Edington, C. D., Stokes, C. L., Griffith, L. G., & Cirit, M. (2017) · The AAPS Journal · doi:10.1208/s12248-017-0122-4 · Cited by 222
Baudy, A. R., Otieno, M. A., Hewitt, P., Gan, J., Roth, A., Keller, D., Sura, R., Van Vleet, T. R., & Proctor, W. R. (2020) · Lab on a Chip · doi:10.1039/c9lc00768g · Cited by 150
Fowler, S., Chen, W. L. K., Duignan, D. B., Gupta, A., Hariparsad, N., Kenny, J. R., Lai, W. G., Liras, J., Phillips, J. A., & Gan, J. (2020) · Lab on a Chip · doi:10.1039/c9lc00857h · Cited by 109
Minimizing DILI risk in drug discovery — A screening tool for drug candidates
Schadt, S., Simon, S., Kustermann, S., Boess, F., McGinnis, C., Brink, A., Lieven, R., Fowler, S., Youdim, K., Ullah, M., et al. (2015) · Toxicology in Vitro · doi:10.1016/j.tiv.2015.09.019 · Cited by 89
Maass, C., Stokes, C. L., Griffith, L. G., & Cirit, M. (2017) · Integrative Biology · doi:10.1039/c6ib00243a · Cited by 72
Cited by
Preclinical models of idiosyncratic drug-induced liver injury (iDILI): Moving towards prediction
Segovia-Zafra, A., Di Zeo-Sánchez, D. E., López-Gómez, C., Pérez-Valdés, Z., García-Fuentes, E., Andrade, R. J., Lucena, M. I., & Villanueva-Paz, M. (2021) · Acta Pharmaceutica Sinica B · doi:10.1016/j.apsb.2021.11.013 · Cited by 70
3D human liver spheroids for translational pharmacology and toxicology
Ingelman‐Sundberg, M., & Lauschke, V. M. (2022) · Basic & Clinical Pharmacology & Toxicology · doi:10.1111/bcpt.13587 · Cited by 62
Kammerer, S. (2021) · International Journal of Molecular Sciences · doi:10.3390/ijms221910214 · Cited by 59
Microphysiological Systems Evaluation: Experience of TEX-VAL Tissue Chip Testing Consortium
Rusyn, I., Sakolish, C., Kato, Y., Stephan, C., Vergara, L., Hewitt, P., Bhaskaran, V., Davis, M., Hardwick, R. N., Ferguson, S. S., et al. (2022) · Toxicological Sciences · doi:10.1093/toxsci/kfac061 · Cited by 43
Tomlinson, L., Ramsden, D., Leite, S. B., Beken, S., Bonzo, J. A., Brown, P., Candarlioglu, P. L., Chan, T. S., Chen, E., Choi, C. K., et al. (2024) · Advanced Biology · doi:10.1002/adbi.202300131 · Cited by 33
Guo, K., & van den Beucken, T. (2024) · Cell & Bioscience · doi:10.1186/s13578-024-01317-2 · Cited by 28
Developing Liver Microphysiological Systems for Biomedical Applications
Wang, J., Wu, X., Zhao, J., Ren, H., & Zhao, Y. (2024) · Advanced Healthcare Materials · doi:10.1002/adhm.202302217 · Cited by 27
Myszczyszyn, A., Muench, A., Lehmann, V., Sinnige, T., van Steenbeek, F. G., Bouwmeester, M., Samsom, R.-A., Keuper-Navis, M., van der Made, T. K., Kogan, D., et al. (2025) · Biofabrication · doi:10.1088/1758-5090/adc3ce · Cited by 14
Metadata
- Authors
- Rubiano, A., Indapurkar, A., Yokosawa, R., Miedzik, A., Rosenzweig, B., Arefin, A., Moulin, C. M., Dame, K., Hartman, N., Volpe, D. A., Matta, M. K., Hughes, D. J., Strauss, D. G., Kostrzewski, T., & Ribeiro, A. J. S.
- Venue
- Clinical and Translational Science
- Publisher
- Wiley
- Published
- 2021-04-03
- Volume
- 14
- Issue
- 3
- Pages
- 1049-1061
- ISSN
- 1752-8054 (ISSN-L)
- 1752-8062
- OpenAlex
- W3115203926
- Cited by
- 96
- References
- 9
- FWCI
- 9.15
- Type
- journal article
- Language
- en
- Open access
- gold
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.