Prosthetic vision: devices, patient outcomes and retinal research
The DOI matches its Crossref record; 36 of the 36 references it cites were found in a registry or an index.
Abstract
Retinal disease and its associated retinal degeneration can lead to the loss of photoreceptors and therefore, profound blindness. While retinal degeneration destroys the photoreceptors, the neural circuits that convey information from the eye to the brain are sufficiently preserved to make it possible to restore sight using prosthetic devices. Typically, these devices consist of a digital camera and an implantable neurostimulator. The image sensor in a digital camera has the same spatiotopic arrangement as the photoreceptors of the retina. Therefore, it is possible to extract meaningful spatial information from an image and deliver it via an array of stimulating electrodes directly to the surviving retinal circuits. Here, we review the structure and function of normal and degenerate retina. The different approaches to prosthetic implant design are described in the context of human and preclinical trials. In the last section, we review studies of electrical properties of the retina and its response to electrical stimulation. These types of investigation are currently assessing a number of key challenges identified in human trials, including stimulation efficacy, spatial localisation, desensitisation to repetitive stimulation and selective activation of retinal cell populations.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Human photoreceptor topography
Curcio, C. A., Sloan, K. R., Kalina, R. E., & Hendrickson, A. E. (1990) · Journal of Comparative Neurology · doi:10.1002/cne.902920402 · Cited by 3,167
DISCHARGE PATTERNS AND FUNCTIONAL ORGANIZATION OF MAMMALIAN RETINA
Kuffler, S. W. (1953) · Journal of Neurophysiology · doi:10.1152/jn.1953.16.1.37 · Cited by 2,609
Neural Stimulation and Recording Electrodes
Cogan, S. F. (2008) · Annual Review of Biomedical Engineering · doi:10.1146/annurev.bioeng.10.061807.160518 · Cited by 2,243
Electrical stimulation of excitable tissue: design of efficacious and safe protocols
Merrill, D. R., Bikson, M., & Jefferys, J. G. R. (2005) · Journal of Neuroscience Methods · doi:10.1016/j.jneumeth.2004.10.020 · Cited by 2,078 · cited 4×
“The use of short duration biphasic waveforms of the order of tens of microseconds in duration mitigate the production of such species with the second phase acting to reverse the offending electrochemical reactions.(53) Chemical and physiological damage can also result, if the electrode material is not biocompatible, i…”
BackgroundInfluentialThe sensations produced by electrical stimulation of the visual cortex
Brindley, G. S., & Lewin, W. S. (1968) · The Journal of Physiology · doi:10.1113/jphysiol.1968.sp008519 · Cited by 1,170
A point mutation of the rhodopsin gene in one form of retinitis pigmentosa
Dryja, T. P., McGee, T. L., Reichel, E., Hahn, L. B., Cowley, G. S., Yandell, D. W., Sandberg, M. A., & Berson, E. L. (1990) · Nature · doi:10.1038/343364a0 · Cited by 1,072 · cited 1×
“398 alternative animal model, the transgenically engineered P23H rat, is a model of the most prevalent genotype for this type of retinitis pigmentosa.(51,52) The identification of genetic sequences, which give rise to retinitis pigmentosa has clearly demonstrated that it is a group of diseases characterised by varying…”
BackgroundVisual perception in a blind subject with a chronic microelectronic retinal prosthesis
Humayun, M. S., Weiland, J. D., Fujii, G. Y., Greenberg, R., Williamson, R., Little, J., Mech, B., Cimmarusti, V., Van Boemel, G., Dagnelie, G., et al. (2003) · Vision Research · doi:10.1016/s0042-6989(03)00457-7 · Cited by 856
Retinal degeneration mutants in the mouse
Chang, B., Hawes, N. L., Hurd, R. E., Davisson, M. T., Nusinowitz, S., & Heckenlively, J. R. (2002) · Vision Research · doi:10.1016/s0042-6989(01)00146-8 · Cited by 840 · cited 2×
“In the case of rd10 mice, photoreceptor degeneration does not coincide with early development of the retina, while these two processes occur simultaneously in the rd1 mouse.(142,143) Further, light responses in the rd10 mouse last for several weeks more than those of the rd1 mouse.”
BackgroundSubretinal electronic chips allow blind patients to read letters and combine them to words
Zrenner, E., Bartz-Schmidt, K. U., Benav, H., Besch, D., Bruckmann, A., Gabel, V.-P., Gekeler, F., Greppmaier, U., Harscher, A., Kibbel, S., et al. (2011) · Proceedings of the Royal Society B: Biological Sciences · doi:10.1098/rspb.2010.1747 · Cited by 819 · cited 10×
“locate a high contrast image on a screen, for example, in one of four locations.(70,91,99,100) Across studies, most subjects perform this kind of task above chance with their device on but perform more poorly or at chance with the device off (Spatial Localisation column of Table 2).”
BackgroundMethodResultInfluentialInterim results from the international trial of Second Sight's visual prosthesis
Humayun, M. S., Dorn, J. D., da Cruz, L., Dagnelie, G., Sahel, J.-A., Stanga, P. E., Cideciyan, A. V., Duncan, J. L., Eliott, D., Filley, E., et al. (2012) · Ophthalmology · doi:10.1016/j.ophtha.2011.09.028 · Cited by 700 · cited 3×
“In a larger study of 30 subjects implanted with an epiretinal device consisting of 60 electrodes (200μmdiameter, Figure 4A), Humayun et al.(96) reported that all subjects reported visual percepts, when the device was active and 96 per cent of subjects were able to perform significantly better in spatial localisation t…”
Background
Cited by
Artificial intelligence for clinical trial design
Harrer, S., Shah, P., Antony, B., & Hu, J. (2019) · Trends in Pharmacological Sciences · doi:10.1016/j.tips.2019.05.005 · Cited by 672
“Neural implants Retinal stimulation electrodes Bionic Eye [59]”
BackgroundRetinal stimulation strategies to restore vision: fundamentals and systems
Yue, L., Weiland, J. D., Roska, B., & Humayun, M. S. (2016) · Progress in Retinal and Eye Research · doi:10.1016/j.preteyeres.2016.05.002 · Cited by 272
“Abundance of blood vessels at choroid makes the thermal dissipation less of a concern as heat generated at the choroid layer will be carried away by the increased blood flow (Hadjinicolaou et al., 2015; Parver et al., 1983).”
Contemporary approaches to visual prostheses
Mirochnik, R. M., & Pezaris, J. S. (2019) · Military Medical Research · doi:10.1186/s40779-019-0206-9 · Cited by 58
Metadata
- Authors
- Hadjinicolaou, A. E., Meffin, H., Maturana, M. I., Cloherty, S. L., & Ibbotson, M. R.
- Venue
- Clinical and Experimental Optometry
- Publisher
- Informa UK Limited
- Published
- 2015-09-01
- Volume
- 98
- Issue
- 5
- Pages
- 395-410
- ISSN
- 0816-4622 (ISSN-L)
- 1444-0938
- OpenAlex
- W2109527187
- Cited by
- 35
- References
- 36
- FWCI
- 2.20
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.