CoChat

Specificity and sensitivity of commercially available assays for glucagon‐like peptide‐1 ( GLP ‐1): implications for GLP ‐1 measurements in clinical studies

Bak, M. J., Wewer Albrechtsen, N. J., Pedersen, J., Knop, F. K., Vilsbøll, T., Jørgensen, N. B., Hartmann, B., Deacon, C. F., Dragsted, L. O., Holst, J. J. · 2014 · Diabetes, Obesity and Metabolism
Cited by 108

The DOI matches its Crossref record; 4 of the 4 references it cites were found in a registry or an index.

Abstract

Aims: To evaluate the performances of commercially available glucagon‐like peptide‐1 (GLP‐1) assays and the implications for clinical studies. Methods: Known concentrations (5–300 pmol/l) of synthetic GLP‐1 isoforms (GLP‐1 1‐36NH 2 , 7‐36NH 2 , 9‐36NH 2 , 1‐37, 7‐37 and 9‐37) were added to the matrix (assay buffer) supplied with 10 different kits and to human plasma, and recoveries were determined. Assays yielding meaningful results were analysed for precision and sensitivity by repeated analysis and ability to discriminate low concentrations. Endogenous GLP‐1 levels in clinical samples were assessed using three commercial kits. Results: The USCN LIFE assay detected none of the GLP‐1 isoforms. The active GLP‐1 enzyme‐linked immunosorbent assays (ELISAs) from Millipore and DRG appeared identical and were specific for intact GLP‐1 in buffer and plasma. The Meso Scale Discovery (MSD) total GLP‐1 kit detected all six GLP‐1 isoforms, although recovery of non‐active forms was incomplete, especially in plasma. Millipore total GLP‐1 ELISA kit detected all isoforms in buffer, but mainly amidated forms in plasma. The Alpco, Phoenix and Bio‐Rad kits detected only amidated GLP‐1, but the Alpco kit had a limited measurement range (30 pmol/l), the Phoenix kit had incomplete recovery in plasma and the Bio‐Rad kit was insensitive (detection limit in plasma 40 pmol/l). The pattern of postprandial GLP‐1 responses in clinical samples was similar between the kits tested, but the absolute concentrations measured varied. Conclusions: The specificity and sensitivity of commercially available kits for the analysis of GLP‐1 levels vary considerably. This should be taken into account when selecting which assay to use and when comparing data from different studies.

Overview

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1111/dom.12352

Cites

4 of 4 references verified0 citation errors · 0 not checkable

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cites

Cited by

See all 108

Metadata

Authors
Bak, M. J., Wewer Albrechtsen, N. J., Pedersen, J., Knop, F. K., Vilsbøll, T., Jørgensen, N. B., Hartmann, B., Deacon, C. F., Dragsted, L. O., & Holst, J. J.
Venue
Diabetes, Obesity and Metabolism
Publisher
Wiley
Published
2014-07-22
Volume
16
Issue
11
Pages
1155-1164
ISSN
  • 1462-8902 (ISSN-L)
  • 1463-1326
OpenAlex
W2083290730
Cited by
108
References
4
FWCI
8.86
Type
journal article
Language
en
Open access
closed

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.