Real‐world performance of hybrid closed loop in youth, young adults, adults and older adults with type 1 diabetes: Identifying a clinical target for hybrid closed‐loop use
The DOI matches its Crossref record; 9 of the 9 references it cites were found in a registry or an index.
Abstract
Aim: To describe real‐world hybrid closed loop (HCL) use and glycaemic outcomes across the lifespan and identify a clinical threshold for HCL use associated with meeting the internationally recommended target of 70% sensor glucose time in range (TIR; 70‐180 mg/dL). Materials and Methods: Mixed models examined MiniMed 670G HCL use and glycaemic outcomes in 276 people with type 1 diabetes from four age groups: youth (aged <18 years), young adults (18‐25 years), adults (26‐49 years) and older adults (≥50 years) for 1 year. ROC analysis identified the minimum percentage HCL use associated with meeting the TIR goal of 70%. Results: HCL use at month 1 was 70.7% ± 2.9% for youth, 71.0% ± 3.8% for young adults, 78.9% ± 2.1% for adults and 84.7% ± 3.8% in older adults. HCL use declined significantly at 12 months to 49.3% ± 3.2% in youth ( P < .001) and 55.7% ± 4.3% in young adults ( P = .002). HCL use was sustained at 12 months in adults (76.4% ± 2.2%, P = .36) and older adults (80.4% ± 3.9%, P = .36). HCL use of 70.6% was associated with 70% TIR (sensitivity 58.3%, specificity 85%, AUC 0.77). Older age, 80% or higher continuous glucose monitor use and four or more blood glucose checks per day were associated with attaining the HCL‐use threshold. Conclusions: HCL use of 70% or higher may be a useful target for clinicians to use to assist people with diabetes in attaining glycaemic goals. Youth may struggle with HCL use more than adults and require clinical intervention to help sustain HCL use across time.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Battelino, T., Danne, T., Bergenstal, R. M., Amiel, S. A., Beck, R., Biester, T., Bosi, E., Buckingham, B. A., Cefalu, W. T., Close, K. L., et al. (2019) · Diabetes Care · doi:10.2337/dci19-0028 · Cited by 4,237 · cited 1×
“Additionally, there is a gap in the literature investigating what percentage of HCL use is necessary to realize glycaemic benefits in the real world, specifically the internationally recommended target of 70% TIR, which is endorsed by the American Diabetes Association (ADA) and many other professional diabetes organiz…”
BackgroundInternational consensus on use of continuous glucose monitoring
Danne, T., Nimri, R., Battelino, T., Bergenstal, R. M., Close, K. L., DeVries, J. H., Garg, S., Heinemann, L., Hirsch, I., Amiel, S. A., et al. (2017) · Diabetes Care · doi:10.2337/dc17-1600 · Cited by 2,069 · cited 1×
“Sensor glucose values were classified as percentage time below target range (TBR; <70 mg/dL), percentage TIR (70-180 mg/dL) and percentage time above target range (>180 mg/dL).(10) Mean sensor glucose was also reported.”
BackgroundState of Type 1 Diabetes Management and Outcomes from the T1D Exchange in 2016–2018
Foster, N. C., Beck, R. W., Miller, K. M., Clements, M. A., Rickels, M. R., DiMeglio, L. A., Maahs, D. M., Tamborlane, W. V., Bergenstal, R., Smith, E., et al. (2019) · Diabetes Technology & Therapeutics · doi:10.1089/dia.2018.0384 · Cited by 1,907
Six-Month Randomized, Multicenter Trial of Closed-Loop Control in Type 1 Diabetes
Brown, S. A., Kovatchev, B. P., Raghinaru, D., Lum, J. W., Buckingham, B. A., Kudva, Y. C., Laffel, L. M., Levy, C. J., Pinsker, J. E., Wadwa, R. P., et al. (2019) · New England Journal of Medicine · doi:10.1056/nejmoa1907863 · Cited by 1,030
Self-citationGarg, S. K., Weinzimer, S. A., Tamborlane, W. V., Buckingham, B. A., Bode, B. W., Bailey, T. S., Brazg, R. L., Ilany, J., Slover, R. H., Anderson, S. M., et al. (2017) · Diabetes Technology & Therapeutics · doi:10.1089/dia.2016.0421 · Cited by 585 · cited 1×
“Two single-arm clinical trials of 670G HCL showed safety and improvements in glycaemic control, evidenced by increased sensor time in target range (TIR; 70-180 mg/dL) and reduced HbA1c in youth and adults ranging from 7 to 75 years of age.(1,2) Observational studies analysing the impact of the 670G HCL system in clini…”
BackgroundBergenstal, R. M., Nimri, R., Beck, R. W., Criego, A., Laffel, L., Schatz, D., Battelino, T., Danne, T., Weinzimer, S. A., Sibayan, J., et al. (2021) · The Lancet · doi:10.1016/s0140-6736(20)32514-9 · Cited by 344
Tanenbaum, M. L., Hanes, S. J., Miller, K. M., Naranjo, D., Bensen, R., & Hood, K. K. (2017) · Diabetes Care · doi:10.2337/dc16-1536 · Cited by 296
One year clinical experience of the first commercial hybrid closed-loop system
Lal, R. A., Basina, M., Maahs, D. M., Hood, K., Buckingham, B., & Wilson, D. M. (2019) · Diabetes Care · doi:10.2337/dc19-0855 · Cited by 215
Sherr, J. L., Buckingham, B. A., Forlenza, G. P., Galderisi, A., Ekhlaspour, L., Wadwa, R. P., Carria, L., Hsu, L., Berget, C., Peyser, T. A., et al. (2020) · Diabetes Technology & Therapeutics · doi:10.1089/dia.2019.0286 · Cited by 92
Self-citation
Cited by
Phillip, M., Nimri, R., Bergenstal, R. M., Barnard-Kelly, K., Danne, T., Hovorka, R., Kovatchev, B. P., Messer, L. H., Parkin, C. G., Ambler-Osborn, L., et al. (2023) · Endocrine Reviews · doi:10.1210/endrev/bnac022 · Cited by 443
Self-citationBoughton, C. K., Hartnell, S., Thabit, H., Mubita, W. M., Draxlbauer, K., Poettler, T., Wilinska, M. E., Hood, K. K., Mader, J. K., Narendran, P., et al. (2022) · The Lancet Healthy Longevity · doi:10.1016/s2666-7568(22)00005-8 · Cited by 127
McAuley, S. A., Trawley, S., Vogrin, S., Ward, G. M., Fourlanos, S., Grills, C. A., Lee, M. H., Alipoor, A. M., O’Neal, D. N., O’Regan, N. A., et al. (2022) · Diabetes Care · doi:10.2337/dc21-1667 · Cited by 117
Karakus, K. E., Akturk, H. K., Alonso, G. T., Snell-Bergeon, J. K., & Shah, V. N. (2023) · Diabetes Care · doi:10.2337/dc23-0495 · Cited by 52
Self-citation
Metadata
- Authors
- Berget, C., Akturk, H. K., Messer, L. H., Vigers, T., Pyle, L., Snell‐Bergeon, J., Driscoll, K. A., & Forlenza, G. P.
- Venue
- Diabetes, Obesity and Metabolism
- Publisher
- Wiley
- Published
- 2021-06-09
- Volume
- 23
- Issue
- 9
- Pages
- 2048-2057
- ISSN
- 1462-8902 (ISSN-L)
- 1463-1326
- OpenAlex
- W3161933594
- Cited by
- 46
- References
- 9
- FWCI
- 6.08
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Real‐world performance of hybrid closed loop in youth, young adults, adults and older adults with type 1 diabetes: Identifying a clinical target for hybrid closed‐loop use. https://app.cochat.ai/papers/10.1111/dom.14441
- The paper
- Berget, C., Akturk, H. K., Messer, L. H., Vigers, T., Pyle, L., Snell‐Bergeon, J., Driscoll, K. A., & Forlenza, G. P. (2021). Real‐world performance of hybrid closed loop in youth, young adults, adults and older adults with type 1 diabetes: Identifying a clinical target for hybrid closed‐loop use. Diabetes, Obesity and Metabolism. https://doi.org/10.1111/dom.14441
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.