Insulin induces a progressive increase in the resistance of subcutaneous tissue to fluid flow: Implications for insulin pump therapy

Open access
Regittnig, Werner, Tschaikner, Mathias, Tuca, Alexandru‐Cristian, Simic, Amra, Feiel, Jürgen, Schaller‐Ammann, Roland, Licht, Alexander H., Jungklaus, Miró +1 more·2022·Diabetes, Obesity and Metabolism

Abstract

Aim: To determine the effect of insulin on the resistance of subcutaneous tissue to the flow of infusion fluids. Materials and methods: Thirty subjects with type 1 diabetes wore two Accu‐Chek Spirit Combo insulin pumps with Accu‐Chek FlexLink infusion sets (Roche Diabetes Care, Mannheim, Germany) for 7 days. One pump was filled with insulin aspart (Novo Nordisk, Bagsvaerd, Denmark) and used for continuous subcutaneous insulin infusion (CSII). The other pump was filled with insulin diluting medium (IDM; Novo Nordisk) and used to deliver IDM subcutaneously at rates identical to those employed for CSII. Both infusion sites were assessed daily by measuring the pressure required to infuse various bolus amounts of IDM. Results: On day 1, maximum pressure (P max ) and tissue flow resistance (TFR; calculated from measured pressure profiles) were similar for both infusion sites ( P > 0.20). During the subsequent study days, the P max and TFR values observed at the IDM infusion site remained at levels comparable to those seen on day 1 ( P > 0.13). However, at the site of CSII, P max and TFR progressively increased with CSII duration. By the end of day 7, P max and TFR reached 25.8 */2.11 kPa (geometric mean */geometric standard deviation) and 8.64 */3.48 kPa*s/μL, respectively, representing a remarkable 3.5‐ and 20.6‐fold increase relative to the respective P max and TFR values observed on day 1 ( P < 0.001). Conclusion: Our results suggest that insulin induces a progressive increase in the resistance of subcutaneous tissue to the introduction of fluid; this has important implications for the future design of insulin pumps and infusion sets.

The claims and statistics of this paper haven’t been checked yet.

Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1111/dom.14594

Cites

5 of 5 references verified0 citation errors · 0 not checkable

Statistics

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.

A few free checks a day · papers already verified open instantly · results are public

Claims other papers make about this one

Each is checked against this paper’s own text: does it say what the citing paper says it does?

  • SIND may occur as frequently as once per month and is detected more frequently by chemical measurement of (or by symptoms of) hyperglycemia or DKA than by pump alerts or alarms.

    “Survey data and pump downloads reveal that SIND may occur as frequently as once per month and is detected more frequently by chemical measurement of (or by symptoms of) hyperglycemia or DKA than by pump alerts or alarms [22], [23].”

    From Performance of a Continuous Subcutaneous Insulin Infusion (CSII) Pump With Acoustic Volume and Flow Sensing in Simulated High-Consequence Situations (2024) · cites this paper as [23]

    The Discussion (page unavailable) says infusion-site leakage often goes unnoticed until hyperglycaemia is detected because current pumps lack leakage-detection alarms. It does not establish that SIND occurs once per month, report survey or pump-download findings, or compare detection by DKA symptoms with pump alerts across SIND events. (LLM, conf=0.83)

    Experimental — accuracy not yet measured
  • Current occlusion alarm systems cannot detect other types of infusion failures such as leakages, dislodged cannulas, and silent occlusions.

    “However, these detection thresholds are not standardized across manufacturers and cannot detect other types of infusion failures such as leakages, dislodged cannulas, and “silent” (ie, no alert) occlusions.15,16”

    From Development of a Real-time Force-based Algorithm for Infusion Failure Detection (2024) · cites this paper as [15]

    The Discussion (page unavailable) says current pumps have no leakage-detection alarms and that most cannula malplacements may go unrecognized for hours. It also says some malplacements are eventually recognized by high-pressure alarms, so an absolute inability to detect them overstates the source. The paper does not address “silent” occlusions. (LLM, conf=0.86)

    Experimental — accuracy not yet measured
  • Occlusion detection thresholds are not standardized across manufacturers.

    “However, these detection thresholds are not standardized across manufacturers and cannot detect other types of infusion failures such as leakages, dislodged cannulas, and “silent” (ie, no alert) occlusions.15,16”
  • Testing of retrofitted pressure sensors in CSII pumps suggests that the incorporation of more precise fluid monitoring could improve infusion failure detection.

    “Alternatively, the testing of retrofitted pressure sensors in CSII pumps suggests that the incorporation of more precise fluid monitoring could improve the infusion failure detection.15”

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Cites

Flagged first, then by citations

Research works printed but not linked: 27

  1. [1]Beck RW, Bergenstal RM, Laffel LM, Pickup JC. Advances in technology for management of type 1 diabetes. Lancet. 2019; 394: 1265‐ 1273. 31533908
  2. [2]Tauschmann M, Hovorka R. Technology in the management of type 1 diabetes mellitus ‐ current status and future prospects. Nat Rev Endocrinol. 2018; 14: 464‐ 475. 29946127
  3. [4]Philip BK, Philip JH. Characterization of flow in intravenous catheters. IEEE Trans Biomed Eng. 1986; 33: 529‐ 531. 3710511
  4. [5]Philip JH, Philip BK. Simplified approach to assessing intravenous flow characteristics in the therapeutic infusion range. IEEE Trans Biomed Eng. 1988; 35: 1093‐ 1094. 3220504
  5. [6]Levick JR. Flow through interstitium and other fibrous matrices. Q J Exp Physiol. 1987; 72: 409‐ 437. 3321140
  6. [7]Swartz MA, Fleury ME. Interstitial flow and its effects in soft tissues. Annu Rev Biomed Eng. 2007; 9: 229‐ 256. 17459001
  7. [8]Richter WF, Bhansali SG, Morris ME. Mechanistic determinants of biotherapeutics absorption following SC administration. AAPS J. 2012; 14: 559‐ 570. 22619041 PMC3385825
  8. [9]Søeborg T, Rasmussen CH, Mosekilde E, Colding‐Jørgensen M. Bioavailability and variability of biphasic insulin mixtures. Eur J Pharm Sci. 2012; 46: 198‐ 208. 21703346
  9. [11]Højbjerre L, Skov‐Jensen C, Kaastrup P, Pedersen PE, Stallknecht B. Effect of steel and teflon infusion catheters on subcutaneous adipose tissue blood flow and infusion counter pressure in humans. Diabetes Technol Ther. 2009; 15: 301‐ 306. 19425878
  10. [12]Patte C, Pleus S, Wiegel C, et al. Effect of infusion rate and indwelling time on tissue resistance pressure in small‐volume subcutaneous infusion like in continuous subcutaneous insulin infusion. Diabetes Technol Ther. 2013; 15: 289‐ 294. 23427865
  11. [16]Greenwood JA, Sandomire MM. Sample size required for estimating the standard deviation as a per cent of its true value. J Am Stat Assoc. 1950; 45: 257‐ 260.
  12. [17]Burnett RW. Accurate estimation of standard deviations for quantitative methods used in clinical chemistry. Clin Chem. 1975; 21: 1935‐ 1938. 1192586
  13. [18]Brange J. Galenics of Insulin. Berlin, Heidelberg, New York: Springer‐Verlag; 1987.
  14. [19]Hrynyk M, Neufeld RJ. Insulin and wound healing. Burns. 2014; 40: 1433‐ 1446. 24810536
  15. [20]Wang J, Xu J. Effects of topical insulin on wound healing – a review of animal and human evidences. Diabetes Metab Syndr Obes. 2020; 13: 719‐ 727. 32214835 PMC7078652
  16. [21]Swinney MR, Cox AL, Hawkins ED, et al. Insulin, not the preservative m‐cresol, instigates loss of infusion site patency over extended durations of CSII in diabetic swine. J Pharm Sci. 2020; 110: 1418‐ 1426. 33321138
  17. [22]Karlin AW, Ly TT, Pyle L, et al. Duration of infusion set survival in lipohypertrophy versus nonlipohypertrophied tissue in patients with type 1 diabetes. Diabetes Technol Ther. 2016; 18: 429‐ 435. 27227290 PMC4931738
  18. [23]Hirsch L, Byron K, Gibney M. Intramuscular risk at insulin injection sites – measurement of the distance from skin to muscle and rationale for shorter‐length needles for subcutaneous insulin therapy. Diabetes Technol Ther. 2014; 16: 867‐ 873. 25329935
  19. [24]Renard E, Guerci B, Leguerrier AM, Boizel R. Lower rate of initial failures and reduced occurrence of adverse events with a new catheter model for continuous subcutaneous insulin infusion: prospective, two‐period, observational, multicenter study. Diabetes Technol Ther. 2010; 12: 769‐ 773. 20809682
  20. [27]Welsh JB, Vargas S, Williams G, Moberg S. Designing the modern pump – engineering aspects of continuous subcutaneous insulin infusion software. Diabetes Technol Ther. 2010; 12(Suppl 1): S37‐ S42. 20515305
  21. [34]Zhang JY, Shang T, Chattaraj S, et al. Advances in insulin pump infusion sets symposium report. J Diabetes Sci Technol. 2021; 15: 705‐ 709. 33703930 PMC8120061
  22. [35]Melberg SG, Havelund S, Villumsen J, Brange J. Insulin compatibility with polymer materials used in external pump infusion systems. Diabetic Med. 1988; 5: 243‐ 247. 2967145
  23. [36]Slominski AT, Zmijewski MA. Glucocorticoids inhibit wound healing – novel mechanism of action. J Invest Dermatol. 2017; 137: 1012‐ 1014. 28411834 PMC5412951
  24. [37]Lal RA, Hsu L, Zhang J, et al. Longevity of the novel ConvaTec infusion set with lantern technology. Diabetes Obes Metab. 2021; 23: 1973‐ 1977. 33822472 PMC8720264
  25. [38]Waldenmaier D, Zschornack E, Buhr A, Pleus S, Haug C, Freckmann G. A prospective study of insulin infusion set use for up to 7 days – early replacement reasons and impact on glycemic control. Diabetes Technol Ther. 2020; 22: 734‐ 741. 32167382
  26. [39]Odeh RE, Chou YM, Owen DB. The precision for coverages and sample size requirements for normal tolerance intervals. Commun Stat‐Simul C. 1987; 16: 969‐ 985.
  27. [40]Grunberger G, Bhargava A, Ly T, et al. Human regular U‐500 insulin via continuous subcutaneous insulin infusion versus multiple daily injections in adults with type 2 diabetes – the VIVID study. Diabetes Obes Metab. 2020; 22: 434‐ 441. 31865633 PMC7065168

Cited by

Sorted by citations

Authors
Regittnig, W., Tschaikner, M., Tuca, A., Simic, A., Feiel, J., Schaller‐Ammann, R., Licht, A. H., Jungklaus, M., & Pieber, T. R.
Affiliations
  • Medical University of Graz (AT)
  • Joanneum Research (AT)
  • Roche Diabetes Care GmbH (Germany) (DE)
Corresponding author
Regittnig, Werner
Venue
Diabetes, Obesity and Metabolism
Publisher
Wiley
Published
2021-11-17
Volume
24
Issue
3
Pages
455-464
ISSN
  • 1462-8902 (ISSN-L)
  • 1463-1326
OpenAlex
W3209858923
Cited by
27
References
5
Citations by year
2025: 2 · 2024: 7 · 2023: 2 · 2022: 15 · 2021: 1
FWCI
4.67
Type
journal article
Language
en
Open access
Locations
  • Diabetes Obesity and Metabolism (publishedVersion, cc-by-nc-nd)
  • PubMed Central (publishedVersion, cc-by-nc-nd)
  • PubMed (publishedVersion)
Funders
  • Medizinische Universität Graz
  • Roche
Topics
  • Health Sciences › Medicine › Endocrinology, Diabetes and Metabolism › Diabetes Management and Research
  • Physical Sciences › Engineering › Biomedical Engineering › Intravenous Infusion Technology and Safety
  • Health Sciences › Medicine › Dermatology › Skin Diseases and Diabetes
Keywords
insulin, insulin pump therapy, insulin aspart, infusion sets, type 1 diabetes, infusion pressure
MeSH terms
Diabetes Mellitus, Type 1, Humans, Hypoglycemic Agents, Insulin, Insulin Infusion Systems, Subcutaneous Tissue

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review