CoChat

Comparison of MiniMed 780G system performance in users aged younger and older than 15 years: Evidence from 12 870 real‐world users

Open access
Arrieta, Arcelia, Battelino, Tadej, Scaramuzza, Andrea E., Da Silva, Julien, Castañeda, Javier, Cordero, Toni L., Shin, John, Cohen, Ohad · 2022 · Diabetes, Obesity and Metabolism
Cited by 154

The DOI matches its Crossref record; 14 of the 14 references it cites were found in a registry or an index.

Abstract

Aim: To investigate real‐world glycaemic outcomes and goals achieved by users of the MiniMed 780G advanced hybrid closed loop (AHCL) system aged younger and older than 15 years with type 1 diabetes (T1D). Materials and Methods: Data uploaded by MiniMed 780G system users from 27 August 2020 to 22 July 2021 were aggregated and retrospectively analysed based on self‐reported age (≤15 years and >15 years) for three cohorts: (a) post‐AHCL initiation, (b) 6‐month longitudinal post‐AHCL initiation and (c) pre‐ versus post‐AHCL initiation. Analyses included mean percentage of time spent in AHCL and at sensor glucose ranges, insulin delivered and the proportion of users achieving recommended glucose management indicator (GMI < 7.0%) and time in target range (TIR 70‐180 mg/dl > 70%) goals. Results: Users aged 15 years or younger (N = 3211) achieved a GMI of 6.8% ± 0.3% and TIR of 73.9% ± 8.7%, while spending 92.7% of time in AHCL. Users aged older than 15 years (N = 8874) achieved a GMI of 6.8% ± 0.4% and TIR of 76.5% ± 9.4% with 92.3% of time in AHCL. Time spent at less than 70 mg/dl was within the recommended target of less than 4% (3.2% and 2.3%, respectively). Similar outcomes were observed for each group (N = 790 and N = 1642, respectively) in the first month following AHCL initiation, and were sustained over the 6‐month observation period. Conclusions: This real‐world analysis shows that more than 75% of users with T1D aged 15 years or younger using the MiniMed 780G system achieved international consensus‐recommended glycaemic control, mirroring the achievements of the population aged older than 15 years.

Overview

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1111/dom.14714

Cites

14 of 14 references verified0 citation errors · 0 not checkable

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cites

Show all 14 references

Cited by

Metadata

Authors
Arrieta, A., Battelino, T., Scaramuzza, A. E., Da Silva, J., Castañeda, J., Cordero, T. L., Shin, J., & Cohen, O.
Venue
Diabetes, Obesity and Metabolism
Publisher
Wiley
Published
2022-05-12
Volume
24
Issue
7
Pages
1370-1379
ISSN
  • 1462-8902 (ISSN-L)
  • 1463-1326
OpenAlex
W4223439323
Cited by
154
References
14
FWCI
20.48
Type
journal article
Language
en
Open access
hybrid

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.