Switching from constant voltage to constant current in deep brain stimulation: a multicenter experience of mixed implants for movement disorders
Open accessThe DOI matches its Crossref record; 1 of the 1 references it cites were found in a registry or an index.
Abstract
Background and purpose: For many years deep brain stimulation (DBS) devices relied only on voltage‐controlled stimulation (CV), but recently current‐controlled devices have been developed and approved for new implants as well as for replacement of CV devices after battery drain. Constant‐current (CC) stimulation has been demonstrated to be effective in new implanted parkinsonian and dystonic patients, but the effect of switching to CC therapy in patients chronically stimulated with CV implantable pulse generators (IPG s) has not been assessed. This report shows the results of a consecutive retrospective data collection performed at five Italian centers before and after replacement of constant‐voltage with constant‐current DBS devices, in order to verify the clinical efficacy and safety of this procedure. Methods: Nineteen patients with Parkinson's disease or dystonic syndrome underwent DBS IPG CV/CC replacement. Clinical features and therapy satisfaction were assessed before surgery, 1 week after and 3 and 6 months after replacement. Programming settings and impedances were recorded before removing the CV device and when the CC IPG s were switched on. Results: The clinical outcome of CC stimulation was similar to that obtained with CV devices and remained stable at 3 and 6 months of follow‐up. Impedance values recorded for CV and CC IPG s were similar. Ninety‐five percent of patients and physicians were satisfied with mixed implants. No adverse events occurred after IPG replacement. Conclusion: Replacing CV with CC IPG s is a safe and effective procedure. Longer follow‐up is necessary to better clarify the impact of CC stimulation on clinical outcome after chronic stimulation in CV mode.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Fakhar, K., Hastings, E., Butson, C. R., Foote, K. D., Zeilman, P., & Okun, M. S. (2013) · PLoS ONE · doi:10.1371/journal.pone.0058665 · Cited by 80
Cited by
Technology of deep brain stimulation: current status and future directions
Krauss, J. K., Lipsman, N., Aziz, T., Boutet, A., Brown, P., Chang, J. W., Davidson, B., Grill, W. M., Hariz, M. I., Horn, A., et al. (2021) · Nature Reviews Neurology · doi:10.1038/s41582-020-00426-z · Cited by 919
Glial responses to implanted electrodes in the brain
Salatino, J. W., Ludwig, K. A., Kozai, T. D. Y., & Purcell, E. K. (2017) · Nature Biomedical Engineering · doi:10.1038/s41551-017-0154-1 · Cited by 642
“As a result, most device manufacturers have moved towards constant-current stimulation paradigms where the charge density delivered by the stimulating electrode does not depend on day-to-day changes in impedance of the tissue/electrode interface 58,59 .”
Dayal, V., Limousin, P., & Foltynie, T. (2017) · Journal of Parkinson’s Disease · doi:10.3233/jpd-171077 · Cited by 108
“A retrospective analysis of 19 patients with PD and dystonic syndromes switched from CV to CC stimulation reported no change in measured clinical outcomes and therapy satisfaction at 6 months [24].”
BackgroundA Fully Integrated RF-Powered Energy-Replenishing Current-Controlled Stimulator
Ha, S., Kim, C., Park, J., Cauwenberghs, G., & Mercier, P. P. (2019) · IEEE Transactions on Biomedical Circuits and Systems · doi:10.1109/tbcas.2018.2881800 · Cited by 35
Metadata
- Authors
- Preda, F., Cavandoli, C., Lettieri, C., Pilleri, M., Antonini, A., Eleopra, R., Mondani, M., Martinuzzi, A., Sarubbo, S., Ghisellini, G., Trezza, A., Cavallo, M. A., Landi, A., & Sensi, M.
- Venue
- European Journal of Neurology
- Publisher
- Wiley
- Published
- 2015-10-25
- Volume
- 23
- Issue
- 1
- Pages
- 190-195
- ISSN
- 1351-5101 (ISSN-L)
- 1468-1331
- OpenAlex
- W2148269042
- Cited by
- 43
- References
- 1
- FWCI
- 3.64
- Type
- journal article
- Language
- en
- Open access
- green
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Switching from constant voltage to constant current in deep brain stimulation: a multicenter experience of mixed implants for movement disorders. https://app.cochat.ai/papers/10.1111/ene.12835
- The paper
- Preda, F., Cavandoli, C., Lettieri, C., Pilleri, M., Antonini, A., Eleopra, R., Mondani, M., Martinuzzi, A., Sarubbo, S., Ghisellini, G., Trezza, A., Cavallo, M. A., Landi, A., & Sensi, M. (2016). Switching from constant voltage to constant current in deep brain stimulation: a multicenter experience of mixed implants for movement disorders. European Journal of Neurology. https://doi.org/10.1111/ene.12835
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.