CoChat

Electromyography‐based seizure detector: Preliminary results comparing a generalized tonic–clonic seizure detection algorithm to video‐EEG recordings

Open access
Szabó, Charles Ákos, Morgan, Lola C., Karkar, Kameel M., Leary, Linda D., Lie, Octavian V., Girouard, Michael, Cavazos, José E. · 2015 · Epilepsia
Cited by 94

The DOI matches its Crossref record; 3 of the 3 references it cites were found in a registry or an index.

Abstract

Summary: Objective: Automatic detection of generalized tonic–clonic seizures (GTCS) will facilitate patient monitoring and early intervention to prevent comorbidities, recurrent seizures, or death. Brain Sentinel (San Antonio, Texas, USA) developed a seizure‐detection algorithm evaluating surface electromyography (sEMG) signals during GTCS. This study aims to validate the seizure‐detection algorithm using inpatient video–electroencephalography (EEG) monitoring. Methods: s EMG was recorded unilaterally from the biceps/triceps muscles in 33 patients (17white/16 male) with a mean age of 40 (range 14–64) years who were admitted for video‐EEG monitoring. Maximum voluntary biceps contraction was measured in each patient to set up the baseline physiologic muscle threshold. The raw EMG signal was recorded using conventional amplifiers, sampling at 1,024 Hz and filtered with a 60 Hz noise detection algorithm before it was processed with three band‐pass filters at pass frequencies of 3–40, 130–240, and 300–400 Hz. A seizure‐detection algorithm utilizing Hotelling's T‐squared power analysis of compound muscle action potentials was used to identify GTCS and correlated with video‐EEG recordings. Results: In 1,399 h of continuous recording, there were 196 epileptic seizures (21 GTCS, 96 myoclonic, 28 tonic, 12 absence, and 42 focal seizures with or without loss of awareness) and 4 nonepileptic spells. During retrospective, offline evaluation of sEMG from the biceps alone, the algorithm detected 20 GTCS (95%) in 11 patients, averaging within 20 s of electroclinical onset of generalized tonic activity, as identified by video‐EEG monitoring. Only one false‐positive detection occurred during the postictal period following a GTCS, but false alarms were not triggered by other seizure types or spells. Significance: Brain Sentinel's seizure detection algorithm demonstrated excellent sensitivity and specificity for identifying GTCS recorded in an epilepsy monitoring unit. Further studies are needed in larger patient groups, including children, especially in the outpatient setting.

Overview

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1111/epi.13083

Cites

3 of 3 references verified0 citation errors · 0 not checkable

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cites

Show all 3 references

Cited by

See all 94

Metadata

Authors
Szabó, C. Á., Morgan, L. C., Karkar, K. M., Leary, L. D., Lie, O. V., Girouard, M., & Cavazos, J. E.
Venue
Epilepsia
Publisher
Wiley
Published
2015-07-20
Volume
56
Issue
9
Pages
1432-1437
ISSN
  • 0013-9580 (ISSN-L)
  • 1528-1167
OpenAlex
W1648904474
Cited by
94
References
3
FWCI
5.72
Type
journal article
Language
en
Open access
hybrid

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

How to cite

Cite CoChat for the checks on this page, and the paper for its own findings.

This page
CoChat. (2026). Citation check: Electromyography‐based seizure detector: Preliminary results comparing a generalized tonic–clonic seizure detection algorithm to video‐EEG recordings. https://app.cochat.ai/papers/10.1111/epi.13083
The paper
Szabó, C. Á., Morgan, L. C., Karkar, K. M., Leary, L. D., Lie, O. V., Girouard, M., & Cavazos, J. E. (2015). Electromyography‐based seizure detector: Preliminary results comparing a generalized tonic–clonic seizure detection algorithm to video‐EEG recordings. Epilepsia. https://doi.org/10.1111/epi.13083

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.