Electromyography‐based seizure detector: Preliminary results comparing a generalized tonic–clonic seizure detection algorithm to video‐EEG recordings
Open accessThe DOI matches its Crossref record; 3 of the 3 references it cites were found in a registry or an index.
Abstract
Summary: Objective: Automatic detection of generalized tonic–clonic seizures (GTCS) will facilitate patient monitoring and early intervention to prevent comorbidities, recurrent seizures, or death. Brain Sentinel (San Antonio, Texas, USA) developed a seizure‐detection algorithm evaluating surface electromyography (sEMG) signals during GTCS. This study aims to validate the seizure‐detection algorithm using inpatient video–electroencephalography (EEG) monitoring. Methods: s EMG was recorded unilaterally from the biceps/triceps muscles in 33 patients (17white/16 male) with a mean age of 40 (range 14–64) years who were admitted for video‐EEG monitoring. Maximum voluntary biceps contraction was measured in each patient to set up the baseline physiologic muscle threshold. The raw EMG signal was recorded using conventional amplifiers, sampling at 1,024 Hz and filtered with a 60 Hz noise detection algorithm before it was processed with three band‐pass filters at pass frequencies of 3–40, 130–240, and 300–400 Hz. A seizure‐detection algorithm utilizing Hotelling's T‐squared power analysis of compound muscle action potentials was used to identify GTCS and correlated with video‐EEG recordings. Results: In 1,399 h of continuous recording, there were 196 epileptic seizures (21 GTCS, 96 myoclonic, 28 tonic, 12 absence, and 42 focal seizures with or without loss of awareness) and 4 nonepileptic spells. During retrospective, offline evaluation of sEMG from the biceps alone, the algorithm detected 20 GTCS (95%) in 11 patients, averaging within 20 s of electroclinical onset of generalized tonic activity, as identified by video‐EEG monitoring. Only one false‐positive detection occurred during the postictal period following a GTCS, but false alarms were not triggered by other seizure types or spells. Significance: Brain Sentinel's seizure detection algorithm demonstrated excellent sensitivity and specificity for identifying GTCS recorded in an epilepsy monitoring unit. Further studies are needed in larger patient groups, including children, especially in the outpatient setting.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Berg, A. T., Berkovic, S. F., Brodie, M. J., Buchhalter, J., Cross, J. H., Van Emde Boas, W., Engel, J., French, J., Glauser, T. A., Mathern, G. W., et al. (2010) · Epilepsia · doi:10.1111/j.1528-1167.2010.02522.x · Cited by 4,363 · cited 2×
“Video-EEG recordings were reviewed by epileptologists (CAS, KMK, LCM, OVL, or LDL) who enumerated and electroclinically classified every seizure type that was recorded during the admission according to the International League Against Epilepsy (ILAE) Guidelines.(15) GTCS were determined by evidence of generalized toni…”
MethodConvulsive seizure detection using a wrist‐worn electrodermal activity and accelerometry biosensor
Poh, M., Loddenkemper, T., Reinsberger, C., Swenson, N. C., Goyal, S., Sabtala, M. C., Madsen, J. R., & Picard, R. W. (2012) · Epilepsia · doi:10.1111/j.1528-1167.2012.03444.x · Cited by 272
Beniczky, S., Polster, T., Kjaer, T. W., & Hjalgrim, H. (2013) · Epilepsia · doi:10.1111/epi.12120 · Cited by 230
Cited by
Diagnostic challenges in epilepsy: seizure under-reporting and seizure detection
Elger, C. E., & Hoppe, C. (2018) · The Lancet Neurology · doi:10.1016/s1474-4422(18)30038-3 · Cited by 403
Automated seizure detection systems and their effectiveness for each type of seizure
Ulate-Campos, A., Coughlin, F., Gaínza-Lein, M., Fernández, I. S., Pearl, P. L., & Loddenkemper, T. (2016) · Seizure · doi:10.1016/j.seizure.2016.06.008 · Cited by 233
Multicenter clinical assessment of improved wearable multimodal convulsive seizure detectors
Onorati, F., Regalia, G., Caborni, C., Migliorini, M., Bender, D., Poh, M., Frazier, C., Kovitch Thropp, E., Mynatt, E. D., Bidwell, J., et al. (2017) · Epilepsia · doi:10.1111/epi.13899 · Cited by 212
Electrophoretic drug delivery for seizure control
Proctor, C. M., Slézia, A., Kaszas, A., Ghestem, A., del Agua, I., Pappa, A.-M., Bernard, C., Williamson, A., & Malliaras, G. G. (2018) · Science Advances · doi:10.1126/sciadv.aau1291 · Cited by 175
Automated real-time detection of tonic-clonic seizures using a wearable EMG device
Beniczky, S., Conradsen, I., Henning, O., Fabricius, M., & Wolf, P. (2018) · Neurology · doi:10.1212/wnl.0000000000004893 · Cited by 171
The Role of Wearable Devices in Chronic Disease Monitoring and Patient Care: A Comprehensive Review
Jafleh, E. A., Alnaqbi, F. A., Almaeeni, H. A., Faqeeh, S., Alzaabi, M. A., & Al Zaman, K. (2024) · Cureus · doi:10.7759/cureus.68921 · Cited by 125
“Currently, the market lacks wearable devices that detect seizures other than TCS [64], and devices under study failed to detect all types of seizures [65,66].”
Bruno, E., Böttcher, S., Viana, P. F., Amengual‐Gual, M., Joseph, B., Epitashvili, N., Dümpelmann, M., Glasstetter, M., Biondi, A., Van Laerhoven, K., et al. (2021) · Epilepsia · doi:10.1111/epi.17044 · Cited by 37
Hubbard, I., Beniczky, S., & Ryvlin, P. (2021) · Frontiers in Neurology · doi:10.3389/fneur.2021.740743 · Cited by 34
Metadata
- Authors
- Szabó, C. Á., Morgan, L. C., Karkar, K. M., Leary, L. D., Lie, O. V., Girouard, M., & Cavazos, J. E.
- Venue
- Epilepsia
- Publisher
- Wiley
- Published
- 2015-07-20
- Volume
- 56
- Issue
- 9
- Pages
- 1432-1437
- ISSN
- 0013-9580 (ISSN-L)
- 1528-1167
- OpenAlex
- W1648904474
- Cited by
- 94
- References
- 3
- FWCI
- 5.72
- Type
- journal article
- Language
- en
- Open access
- hybrid
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.