Automated seizure detection using wearable devices: A clinical practice guideline of the International League Against Epilepsy and the International Federation of Clinical Neurophysiology
The DOI matches its Crossref record; 13 of the 13 references it cites were found in a registry or an index.
Abstract
The objective of this clinical practice guideline (CPG) is to provide recommendations for healthcare personnel working with patients with epilepsy on the use of wearable devices for automated seizure detection in patients with epilepsy, in outpatient, ambulatory settings. The Working Group of the International League Against Epilepsy (ILAE) and the International Federation of Clinical Neurophysiology (IFCN) developed the CPG according to the methodology proposed by the ILAE Epilepsy Guidelines Working Group. We reviewed the published evidence using The Preferred Reporting Items for Systematic Review and Meta‐Analysis (PRISMA) statement and evaluated the evidence and formulated the recommendations following the Grading of Recommendations Assessment, Development and Evaluation (GRADE) system. We found high level of evidence for the accuracy of automated detection of generalized tonic‐clonic seizures (GTCS) and focal‐to‐bilateral tonic‐clonic seizures (FBTCS) and recommend the use of wearable automated seizure detection devices for selected patients when accurate detection of GTCS and FBTCS is recommended as a clinical adjunct. We also found a moderate level of evidence for seizure types without GTCS or FBTCS. However, it was uncertain whether the detected alarms resulted in meaningful clinical outcomes for the patients. We recommend using clinically validated devices for automated detection of GTCS and FBTCS, especially in unsupervised patients, where alarms can result in rapid intervention (weak/conditional recommendation). At present, we do not recommend clinical use of the currently available devices for other seizure types (weak/conditional recommendation). Further research and development are needed to improve the performance of automated seizure detection and to document their accuracy and clinical utility.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
GRADE: an emerging consensus on rating quality of evidence and strength of recommendations
Guyatt, G. H., Oxman, A. D., Vist, G. E., Kunz, R., Falck-Ytter, Y., Alonso-Coello, P., & Schünemann, H. J. (2008) · BMJ · doi:10.1136/bmj.39489.470347.ad · Cited by 23,305
QUADAS-2: a revised tool for the quality assessment of diagnostic accuracy studies
Whiting, P. F., Rutjes, A. W. S., Westwood, M. E., Mallett, S., Deeks, J. J., Reitsma, J. B., Leeflang, M. M. G., Sterne, J. A. C., Bossuyt, P. M. M., & the QUADAS-2 Group* (2011) · Annals of Internal Medicine · doi:10.7326/0003-4819-155-8-201110180-00009 · Cited by 14,199 · cited 2×
“For systematic assessment of risk of bias, we have adapted the items from the Quality Assessment of Diagnostic Accuracy Studies (QUADAS-2) to the specific application for this health technology assessment (Handbook, 2020; Whiting et al., 2011).”
Qualitative Research: Consensus methods for medical and health services research
Jones, J., & Hunter, D. (1995) · BMJ · doi:10.1136/bmj.311.7001.376 · Cited by 3,471
Diagnostic challenges in epilepsy: seizure under-reporting and seizure detection
Elger, C. E., & Hoppe, C. (2018) · The Lancet Neurology · doi:10.1016/s1474-4422(18)30038-3 · Cited by 403
Beniczky, S., Polster, T., Kjaer, T. W., & Hjalgrim, H. (2013) · Epilepsia · doi:10.1111/epi.12120 · Cited by 230
Self-citationMulticenter clinical assessment of improved wearable multimodal convulsive seizure detectors
Onorati, F., Regalia, G., Caborni, C., Migliorini, M., Bender, D., Poh, M., Frazier, C., Kovitch Thropp, E., Mynatt, E. D., Bidwell, J., et al. (2017) · Epilepsia · doi:10.1111/epi.13899 · Cited by 212
Wearable technology in epilepsy: The views of patients, caregivers, and healthcare professionals
Bruno, E., Simblett, S., Lang, A., Biondi, A., Odoi, C., Schulze-Bonhage, A., Wykes, T., & Richardson, M. P. (2018) · Epilepsy & Behavior · doi:10.1016/j.yebeh.2018.05.044 · Cited by 191
Automated Epileptic Seizure Detection Based on Wearable ECG and PPG in a Hospital Environment
Vandecasteele, K., De Cooman, T., Gu, Y., Cleeren, E., Claes, K., Paesschen, W., Huffel, S., & Hunyadi, B. (2017) · Sensors · doi:10.3390/s17102338 · Cited by 174
Machine learning and wearable devices of the future
Beniczky, S., Karoly, P., Nurse, E., Ryvlin, P., & Cook, M. (2021) · Epilepsia · doi:10.1111/epi.16555 · Cited by 155
Self-citationNijsen, T. M. E., Arends, J. B. A. M., Griep, P. A. M., & Cluitmans, P. J. M. (2005) · Epilepsy & Behavior · doi:10.1016/j.yebeh.2005.04.011 · Cited by 139
Cited by
Bruno, E., Böttcher, S., Viana, P. F., Amengual‐Gual, M., Joseph, B., Epitashvili, N., Dümpelmann, M., Glasstetter, M., Biondi, A., Van Laerhoven, K., et al. (2021) · Epilepsia · doi:10.1111/epi.17044 · Cited by 37
Hubbard, I., Beniczky, S., & Ryvlin, P. (2021) · Frontiers in Neurology · doi:10.3389/fneur.2021.740743 · Cited by 34
Self-citationBöttcher, S., Bruno, E., Epitashvili, N., Dümpelmann, M., Zabler, N., Glasstetter, M., Ticcinelli, V., Thorpe, S., Lees, S., Van Laerhoven, K., et al. (2022) · Sensors · doi:10.3390/s22093318 · Cited by 23
“Yet, seizure tracking in an ultra-longterm context at home is needed, both as an automatic alarm to potentially alert carers in the event of a seizure, and as a tool for monitoring and forecasting the disease trajectory [4,5].”
BackgroundInfluentialGlasstetter, M., Böttcher, S., Zabler, N., Epitashvili, N., Dümpelmann, M., Richardson, M. P., & Schulze-Bonhage, A. (2021) · Sensors · doi:10.3390/s21186017 · Cited by 21
“used in epileptic seizure detection are also tailored to the detection of these convulsive seizures [14,15].”
Method
Metadata
- Authors
- Beniczky, S., Wiebe, S., Jeppesen, J., Tatum, W. O., Brazdil, M., Wang, Y., Herman, S. T., & Ryvlin, P.
- Venue
- Epilepsia
- Publisher
- Wiley
- Published
- 2021-03
- Volume
- 62
- Issue
- 3
- Pages
- 632-646
- ISSN
- 0013-9580 (ISSN-L)
- 1528-1167
- OpenAlex
- W3134817637
- Cited by
- 96
- References
- 13
- FWCI
- 9.36
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Automated seizure detection using wearable devices: A clinical practice guideline of the International League Against Epilepsy and the International Federation of Clinical Neurophysiology. https://app.cochat.ai/papers/10.1111/epi.16818
- The paper
- Beniczky, S., Wiebe, S., Jeppesen, J., Tatum, W. O., Brazdil, M., Wang, Y., Herman, S. T., & Ryvlin, P. (2021). Automated seizure detection using wearable devices: A clinical practice guideline of the International League Against Epilepsy and the International Federation of Clinical Neurophysiology. Epilepsia. https://doi.org/10.1111/epi.16818
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.