Cited by 174Non-Invasive Vital Sign MonitoringECG Monitoring and AnalysisEpilepsy research and treatment

Automated Epileptic Seizure Detection Based on Wearable ECG and PPG in a Hospital Environment

Open access
Vandecasteele, Kaat, De Cooman, Thomas, Gu, Ying, Cleeren, Evy, Claes, Kasper, Paesschen, Wim, Huffel, Sabine, Hunyadi, Borbála·2017·Sensors

Abstract

Electrocardiography has added value to automatically detect seizures in temporal lobe epilepsy (TLE) patients. The wired hospital system is not suited for a long-term seizure detection system at home. To address this need, the performance of two wearable devices, based on electrocardiography (ECG) and photoplethysmography (PPG), are compared with hospital ECG using an existing seizure detection algorithm. This algorithm classifies the seizures on the basis of heart rate features, extracted from the heart rate increase. The algorithm was applied to recordings of 11 patients in a hospital setting with 701 h capturing 47 (fronto-)temporal lobe seizures. The sensitivities of the hospital system, the wearable ECG device and the wearable PPG device were respectively 57%, 70% and 32%, with corresponding false alarms per hour of 1.92, 2.11 and 1.80. Whereas seizure detection performance using the wrist-worn PPG device was considerably lower, the performance using the wearable ECG is proven to be similar to that of the hospital ECG.

The claims and statistics of this paper haven’t been checked yet.

Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.3390/s17102338

Cites

25 of 25 references verified0 citation errors · 0 not checkable

Statistics

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.

A few free checks a day · papers already verified open instantly · results are public

Claims other papers make about this one

Each is checked against this paper’s own text: does it say what the citing paper says it does?

  • One study reports that more than half of epileptic seizures in a data set could not be detected from Empatica E4 PPG data due to motion artifacts.

    “One study, for example, reports that more than half of epileptic seizures in a data set could not be detected from Empatica E4 PPG data due to motion artifacts68.”

    From Data quality evaluation in wearable monitoring (2022) · cites this paper as [68]

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Cites

Flagged first, then by citations

Cited by

Sorted by citations

Authors
Vandecasteele, K., De Cooman, T., Gu, Y., Cleeren, E., Claes, K., Paesschen, W., Huffel, S., & Hunyadi, B.
Affiliations
  • IMEC (BE)
  • KU Leuven, Department of Electrical Engineering (ESAT), STADIUS Center for Dynamical Systems, Signal Processing and Data Analytics, Leuven 3001, Belgium
  • KU Leuven (BE)
  • UCB Pharma (Belgium) (BE)
Corresponding author
Vandecasteele, Kaat
Venue
Sensors
Publisher
MDPI AG
Published
2017-10-13
Volume
17
Issue
10
Pages
2338
ISSN
1424-8220 (ISSN-L)
OpenAlex
W2760882705
Cited by
174
References
25
Citations by year
2026: 5 · 2025: 12 · 2024: 22 · 2023: 15 · 2022: 26 · 2021: 35 · 2020: 23 · 2019: 21 · 2018: 15
FWCI
7.25
Type
journal article
Language
en
Open access
Locations
  • Sensors (publishedVersion, cc-by)
  • Europe PMC (PubMed Central) (publishedVersion, cc-by)
  • PubMed Central (publishedVersion, cc-by)
  • PubMed (publishedVersion)
  • Lirias (submittedVersion, other-oa)
  • DOAJ (DOAJ: Directory of Open Access Journals) (submittedVersion, cc-by-sa)
Funders
  • Agentschap Innoveren en Ondernemen (150466:, O&O HBC 2016 0184 eWatch)
  • European Commission (2007–2013, 339804, FP7 2007-2013, FP7/2007)
  • iMinds (HBC.2016.0167)
  • KU Leuven
  • Innoviris
  • Vlaamse regering
  • UCB Pharma
Topics
  • Physical Sciences › Engineering › Biomedical Engineering › Non-Invasive Vital Sign Monitoring
  • Health Sciences › Medicine › Cardiology and Cardiovascular Medicine › ECG Monitoring and Analysis
  • Health Sciences › Medicine › Psychiatry and Mental health › Epilepsy research and treatment
Keywords
seizure detection, temporal lobe epilepsy, wearable ECG, photoplethysmography, wrist-worn sensors
MeSH terms
Wearable Electronic Devices, Algorithms, Electrocardiography, Electroencephalography, Epilepsy, Heart Rate, Hospitals, Humans, Seizures, Photoplethysmography

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review