Cited by 84Infection Control and VentilationIndoor Air Quality and Microbial ExposureTuberculosis Research and Epidemiology

Effect of ventilation improvement during a tuberculosis outbreak in underventilated university buildings

Open access
Du, Chun‐Ru, Wang, Shun‐Chih, Yu, Ming‐Chih, Chiu, Ting‐Fang, Wang, Jann‐Yuan, Chuang, Pei‐Chun, Jou, Ruwen, Chan, Pei‐Chun +1 more·2020·Indoor Air

Abstract

The role of ventilation in preventing tuberculosis (TB) transmission has been widely proposed in infection control guidance. However, conclusive evidence is lacking. Modeling suggested the threshold of ventilation rate to reduce effective reproductive ratio (ratio between new secondary infectious cases and source cases) of TB to below 1 is corresponding to a carbon dioxide (CO2) level of 1000 parts per million (ppm). Here, we measured the effect of improving ventilation rate on a TB outbreak involving 27 TB cases and 1665 contacts in underventilated university buildings. Ventilation engineering decreased the maximum CO2 levels from 3204 ± 50 ppm to 591-603 ppm. Thereafter, the secondary attack rate of new contacts in university dropped to zero (mean follow-up duration: 5.9 years). Exposure to source TB cases under CO2 >1000 ppm indoor environment was a significant risk factor for contacts to become new infectious TB cases (P < .001). After adjusting for effects of contact investigation and latent TB infection treatment, improving ventilation rate to levels with CO2 <1000 ppm was independently associated with a 97% decrease (95% CI: 50%-99.9%) in the incidence of TB among contacts. These results show that maintaining adequate indoor ventilation could be a highly effective strategy for controlling TB outbreaks.

The claims and statistics of this paper haven’t been checked yet.

Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1111/ina.12639

Cites

30 of 30 references verified0 citation errors · 0 not checkable

Statistics

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.

A few free checks a day · papers already verified open instantly · results are public

Claims other papers make about this one

Each is checked against this paper’s own text: does it say what the citing paper says it does?

  • Lack of ventilation in homes has been shown to contribute to the transmission of tuberculosis, and maintaining adequate indoor ventilation can effectively control TB outbreaks.

    “Lack of ventilation in homes has been shown to contribute to the transmission of tuberculosis (TB) (5); maintaining adequate indoor ventilation can effectively control TB outbreaks (34).”

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Cites

Flagged first, then by citations

1 of the 31 references couldn’t be matched to a known paper.

Research works printed but not linked: 2

  1. [8]World Health Organization. WHO Guidelines on Tuberculosis Infection Prevention and Control, 2019 Update, Geneva: World Health Organization; 2019. License: CC BY‐NC‐SA 3.0 IGO. 30933444
  2. [25]World Health Organization (2009). Natural ventilation for infection control in health‐care settings. http://www.who.int/water_sanitation_health/publications/natural_ventilation/en/. Accessed December 1, 2019. 23762969

Cited by

Sorted by citations

Authors
Du, C., Wang, S., Yu, M., Chiu, T., Wang, J., Chuang, P., Jou, R., Chan, P., & Fang, C.
Affiliations
  • Taiwan Centers for Disease Control (TW)
  • Institute of Labor, Occupational Safety And Health, Ministry of Labor (TW)
  • Wan Fang Hospital (TW)
  • Taipei City Hospital (TW)
  • National Taiwan University Hospital (TW)
  • National Taiwan University (TW)
Corresponding author
  • Chan, Pei‐Chun
  • Fang, Chi‐Tai
Venue
Indoor Air
Publisher
Wiley
Published
2020-01-16
Volume
30
Issue
3
Pages
422-432
ISSN
  • 0905-6947 (ISSN-L)
  • 1600-0668
OpenAlex
W2996980267
Cited by
84
References
31
Citations by year
2026: 8 · 2025: 12 · 2024: 14 · 2023: 17 · 2022: 16 · 2021: 12 · 2020: 4 · 2019: 1
FWCI
6.06
Type
journal article
Language
en
Open access
Locations
  • Indoor Air (publishedVersion, cc-by-nc-nd)
  • PubMed Central (publishedVersion, cc-by-nc-nd)
  • PubMed (publishedVersion)
Topics
  • Health Sciences › Medicine › Pulmonary and Respiratory Medicine › Infection Control and Ventilation
  • Physical Sciences › Environmental Science › Health, Toxicology and Mutagenesis › Indoor Air Quality and Microbial Exposure
  • Health Sciences › Medicine › Infectious Diseases › Tuberculosis Research and Epidemiology
Keywords
tuberculosis outbreak, indoor ventilation, CO2 concentration, secondary attack rate, tuberculosis transmission, university buildings, infection control, ventilation rate, latent tuberculosis infection, TB contacts
MeSH terms
Adult, Disease Outbreaks, Female, Humans, Male, Tuberculosis, Universities, Ventilation

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review