Cited by 110Infection Control and VentilationIndoor Air Quality and Microbial ExposureCOVID-19 impact on air quality

Poor ventilation worsens short-range airborne transmission of respiratory infection

Open access
Li, Yuguo, Cheng, Pan, Jia, Wei·2022·Indoor Air

Abstract

To explain the observed phenomenon that most SARS-CoV-2 transmission occurs indoors whereas its outdoor transmission is rare, a simple macroscopic aerosol balance model is developed to link short- and long-range airborne transmission. The model considers the involvement of exhaled droplets with initial diameter ≤50 µm in the short-range airborne route, whereas only a fraction of these droplets with an initial diameter within 15 µm or equivalently a final diameter within 5 µm considered in the long-range airborne route. One surprising finding is that the room ventilation rate significantly affects the short-range airborne route, in contrast to traditional belief. When the ventilation rate in a room is insufficient, the airborne infection risks due to both short- and long-range transmission are high. A ventilation rate of 10 L/s per person provides a similar concentration vs distance decay profile to that in outdoor settings, which provides additional justification for the widely adopted ventilation standard of 10 L/s per person. The newly obtained data do not support the basic assumption in the existing ventilation standard ASHRAE 62.1 (2019) that the required people outdoor air rate is constant if the standard is used directly for respiratory infection control. Instead, it is necessary to increase the ventilation rate when the physical distance between people is less than approximately 2 m.

Integrity signals

Registry

Crossref · 10.1111/ina.12946

Cites

33 of 33 references verified0 citation errors · 0 not checkable

Statistics

Recomputing p-values needs the paper’s full text.

Claims the paper makes

We couldn’t retrieve this paper’s full text, so its claims and self-check weren’t run. The registry and citation checks still apply.

Cites

Flagged first, then by citations

Cited by

Sorted by citations

Authors
Li, Y., Cheng, P., & Jia, W.
Affiliations
University of Hong Kong (HK)
Corresponding author
Li, Yuguo
Venue
Indoor Air
Publisher
Wiley
Published
2021-10-27
Volume
32
Issue
1
Pages
e12946-e12946
ISSN
  • 0905-6947 (ISSN-L)
  • 1600-0668
OpenAlex
W3208868503
Cited by
110
References
33
Citations by year
2026: 12 · 2025: 27 · 2024: 21 · 2023: 24 · 2022: 26
FWCI
11.47
Type
journal article
Language
en
Open access
Locations
  • Indoor Air (publishedVersion)
  • PubMed Central (publishedVersion)
  • PubMed (publishedVersion)
  • The HKU Scholars Hub (University of Hong Kong) (submittedVersion)
Funders
Research Grants Council, University Grants Committee
Topics
  • Health Sciences › Medicine › Pulmonary and Respiratory Medicine › Infection Control and Ventilation
  • Physical Sciences › Environmental Science › Health, Toxicology and Mutagenesis › Indoor Air Quality and Microbial Exposure
  • Physical Sciences › Environmental Science › Global and Planetary Change › COVID-19 impact on air quality
Keywords
SARS-CoV-2 transmission, airborne transmission, long-range transmission, exhaled droplets, droplet size, indoor air quality, ventilation standards, respiratory infection control, distance decay
MeSH terms
COVID-19, SARS-CoV-2, Aerosols, Air Microbiology, Humans, Respiratory Tract Infections, Ventilation, Air Pollution, Indoor

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review