Development and application of an indoor carbon dioxide metric

Open access
Persily, Andrew·2022·Indoor Air

Abstract

Indoor carbon dioxide (CO2) concentrations have been considered for decades in evaluating indoor air quality (IAQ) and ventilation, and more recently in discussions of the risk of airborne infectious disease transmission. However, many of these applications reflect a lack of understanding of the connection between indoor CO2 levels, ventilation, and IAQ. For example, a single indoor concentration such as 1000 ppmv is often used as a metric of IAQ and ventilation without an understanding of the significance of this or any other value. CO2 concentrations are of limited value as IAQ metrics, and a single concentration will not serve as a ventilation indicator for spaces with different occupancies and ventilation requirements. An approach has been developed to estimate a space-specific CO2 level that can serve as a metric of outdoor ventilation rates. The concept is to estimate the CO2 concentration that would be expected in a specific space given its intended or expected ventilation rate, the number of occupants, the rate at which they generate CO2, and the time that has transpired since the space was occupied. This paper describes the approach and presents example calculations for several commercial, institutional, and residential occupancies.

The claims and statistics of this paper haven’t been checked yet.

Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1111/ina.13059

Cites

30 of 30 references verified0 citation errors · 0 not checkable

Statistics

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.

A few free checks a day · papers already verified open instantly · results are public

Claims other papers make about this one

Each is checked against this paper’s own text: does it say what the citing paper says it does?

  • CO2 is considered among the most significant air constituents that impact occupant safety, work productivity, and well-being in the spatial environment.

    “is considered among the most significant air constituents that impact occupant safety, work productivity, and well-being in the spatial environment [3].”

    From A Microalgae Photobioreactor System for Indoor Air Remediation: Empirical Examination of the CO2 Absorption Performance of Spirulina maxima in a NaHCO3-Reduced Medium (2023) · cites this paper as [3]

    The Introduction says that many other indoor contaminants have more significant health and comfort impacts than CO2. It also cautions that reported associations between indoor CO2 and symptoms or performance may reflect lower ventilation and other contaminants, rather than CO2 itself. This runs contrary to describing CO2 as among the most significant constituents affecting occupants. (LLM, conf=0.88)

    Checked by a reasoning model — may be wrong.

    Experimental — accuracy not yet measured
  • Carbon dioxide represents 60~85% of greenhouse gas.

    “carbon dioxide (CO2), which represents 60~85% of greenhouse gas (GHG)”

    From A Microalgae Photobioreactor System for Indoor Air Remediation: Empirical Examination of the CO2 Absorption Performance of Spirulina maxima in a NaHCO3-Reduced Medium (2023) · cites this paper as [3]

    The Introduction discusses indoor CO₂ concentrations in relation to ventilation and air quality, not CO₂’s share of greenhouse gases (page not provided). Searches for greenhouse gases and the 60–85% figure found no passage in our copy addressing that proportion. (LLM, conf=0.76)

    Experimental — accuracy not yet measured

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Cites

Flagged first, then by citations

Research works printed but not linked: 10

  1. Jackson MC, Penn RL, Aldred JR, Zeliger HI, Cude GE, Neace LM, Kuhs JF, Corsi RL. Comparison of metrics for characterizing the quality of indoor air. Presented at: 12th International Conference on Indoor Air Quality and Climate; 2011; Austin, Texas.
  2. Moschandreas D, Yoon S, Demirev D. Validation of the indoor envi- ronmental index and its ability to assess in-office air quality. Indoor Air. 2005;15(11):874-877.
  3. AIVC. Workshop -Is Ventilation the Answer to Indoor Air Quality Control in Buildings? Do we Need Performance-Based Approaches? Air Infiltration and Ventilation Centre; 2017. https://www.aivc.org/ resou rces/colle ction -paper s/volum e/march -14-15-2017-venti latio n-answe r-indoo r-air-quali ty-control
  4. Jones B. Metrics of health risks from indoor air. REHVA J. 2017;54(3):39-44.
  5. Klauss AK, Tull RH, Roots LM, Pfafflin JR. History of the changing concepts in ventilation requirements. ASHRAE J. 1970;12:51-55.
  6. Wargocki P. What we know and should know about ventilation. REHVA J. 2021;58(2):5-13.
  7. Du B, Tandoc MC, Mack ML, Siegel JA. Indoor CO2 concen- trations and cognitive function: a critical review. Indoor Air. 2020;30(6):1067-1082.
  8. Persily AK. Evaluating building IAQ and ventilation with indoor car- bon dioxide. ASHRAE Trans. 1997;103(2):193-204.
  9. Persily AK. Don't blame standard 62.1 for 1000 ppm CO2. ASHRAE J. 2021;63(2):74-75.
  10. Limb MJ. A Review of International Ventilation, Airtightness, Thermal Insulation and Indoor Air Quality Criteria. Air Infiltration and Ventilation Centre, Coventry, Great Britain; 2001. TN 55.

Authors
Persily, A.
Affiliations
National Institute of Standards and Technology (US)
Corresponding author
Persily, Andrew
Venue
Indoor Air
Publisher
Wiley
Published
2022-07
Volume
32
Issue
7
Pages
e13059-e13059
ISSN
  • 0905-6947 (ISSN-L)
  • 1600-0668
OpenAlex
W4286252805
Cited by
104
References
30
Citations by year
2026: 38 · 2025: 22 · 2024: 13 · 2023: 26 · 2022: 4 · 2021: 1
FWCI
6.38
Type
journal article
Language
en
Open access
Locations
  • Indoor Air (publishedVersion, cc-by-nc-nd)
  • PubMed (publishedVersion)
Topics
  • Physical Sciences › Environmental Science › Health, Toxicology and Mutagenesis › Indoor Air Quality and Microbial Exposure
  • Health Sciences › Medicine › Pulmonary and Respiratory Medicine › Infection Control and Ventilation
  • Physical Sciences › Engineering › Building and Construction › Building Energy and Comfort Optimization
Keywords
indoor carbon dioxide, CO2 concentration, indoor air quality, ventilation rate, airborne infectious disease transmission, occupancy, residential buildings, commercial buildings, institutional building
MeSH terms
Air Pollutants, Carbon Dioxide, Environmental Monitoring, Respiration, Ventilation, Air Pollution, Indoor

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review