Ictal SPECT
The DOI matches its Crossref record; 22 of the 22 references it cites were found in a registry or an index.
Abstract
Summary: The localizing value of ictal single‐photon emission computed tomography (SPECT) performed with cerebral blood flow agents in patients with epilepsy is based on cerebral metabolic and perfusion coupling. Ictal hyperperfusion is used to localize the epileptogenic zone noninvasively, and is particularly useful in magnetic resonance (MR)‐negative partial epilepsy and focal cortical dysplasias. Subtraction ictal SPECT coregistered with MRI (SISCOM) improves the localization of the area of hyperperfusion. Ictal SPECT should always be interpreted in the context of a full presurgical evaluation. Early ictal SPECT injections minimize the problem of seizure propagation and of nonlocalization due to an early switch from ictal hyperperfusion to postictal hypoperfusion during brief extratemporal seizures. The degree of thresholding of SISCOM images affects the sensitivity and specificity of ictal SPECT. Ictal hypoperfusion may reflect ictal inhibition or deactivation. Postictal and interictal SPECT studies are less useful to localize the ictal‐onset zone. Statistical parametric mapping analysis of groups of selected ictal–interictal difference images has the potential to demonstrate the evolution of cortical, subcortical, and cerebellar perfusion changes during a particular seizure type, to study seizure‐gating mechanisms, and to provide new insights into the pathophysiology of seizures.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
O'Brien, T. J., So, E. L., Mullan, B. P., Hauser, M. F., Brinkmann, B. H., Bohnen, N. I., Hanson, D., Cascino, G. D., Jack, C. R., & Sharbrough, F. W. (1998) · Neurology · doi:10.1212/wnl.50.2.445 · Cited by 530
Positive and Negative Network Correlations in Temporal Lobe Epilepsy
Blumenfeld, H., McNally, K. A., Vanderhill, S. D., Paige, A. L., Chung, R., Davis, K., Norden, A. D., Stokking, R., Studholme, C., Novotny, E. J., et al. (2004) · Cerebral Cortex · doi:10.1093/cercor/bhh048 · Cited by 332 · cited 1×
“With this method, CPSs in patients with unilateral hippocampal sclerosis have been studied (24,25) (Fig.”
MethodSubtraction peri-ictal SPECT is predictive of extratemporal epilepsy surgery outcome
O’Brien, T. J., So, E. L., Mullan, B. P., Cascino, G. D., Hauser, M. F., Brinkmann, B. H., Sharbrough, F. W., & Meyer, F. B. (2000) · Neurology · doi:10.1212/wnl.55.11.1668 · Cited by 224 · cited 1×
“O’Brien and colleagues (20) reported an excellent outcome when SISCOM localization was concordant with surgical-resection site, but not when SISCOM and resection site were discordant in patients with nonlocalizing MRI findings.”
Siegel, A. M., Jobst, B. C., Thadani, V. M., Rhodes, C. H., Lewis, P. J., Roberts, D. W., & Williamson, P. D. (2001) · Epilepsia · doi:10.1046/j.1528-1157.2001.042007883.x · Cited by 213 · cited 1×
“studies, Siegel and colleagues (19) reported a good seizure outcome in 83% of patients with refractory MR-negative partial epilepsy.”
BackgroundIn vivo optical mapping of epileptic foci and surround inhibition in ferret cerebral cortex
Schwartz, T. H., & Bonhoeffer, T. (2001) · Nature Medicine · doi:10.1038/nm0901-1063 · Cited by 207 · cited 1×
“Further, these SPECT findings corroborate optical imaging experiments that showed a decrease in optical signal together with a decrease in neuronal activity in cortex surrounding an epileptic focus, consistent with ictal surround inhibition (27).”
BackgroundGold, L., & Lauritzen, M. (2002) · Proceedings of the National Academy of Sciences · doi:10.1073/pnas.112012499 · Cited by 205 · cited 3×
“Gold L, Lauritzen M. Neuronal deactivation explains decreased cerebellar blood flow in response to focal cerebral ischemia or suppressed neocortical function.”
BackgroundInfluentialPostictal switch in blood flow distribution and temporal lobe seizures.
Newton, M. R., Berkovic, S. F., Austin, M. C., Rowe, C. C., McKay, W. J., & Bladin, P. F. (1992) · Journal of Neurology, Neurosurgery & Psychiatry · doi:10.1136/jnnp.55.10.891 · Cited by 178 · cited 1×
“seizures (18), but is shorter in extratemporal seizures.”
BackgroundBoonyapisit, K., Najm, I., Klem, G., Ying, Z., Burrier, C., LaPresto, E., Nair, D., Bingaman, W., Prayson, R., & Lüders, H. (2003) · Epilepsia · doi:10.1046/j.1528-1157.2003.08102.x · Cited by 176 · cited 1×
“(22) and Boonyapisit and colleagues (23) reported FCD types with different functional characteristics.”
BackgroundSPECT perfusion changes during complex partial seizures in patients with hippocampal sclerosis
Van Paesschen, W., Dupont, P., Van Driel, G., Van Billoen, H., & Maes, A. (2003) · Brain · doi:10.1093/brain/awg108 · Cited by 175
Self-citationSelective frontal, parietal, and temporal networks in generalized seizures
Blumenfeld, H., Westerveld, M., Ostroff, R. B., Vanderhill, S. D., Freeman, J., Necochea, A., Uranga, P., Tanhehco, T., Smith, A., & Seibyl, J. P. (2003) · NeuroImage · doi:10.1016/s1053-8119(03)00204-0 · Cited by 164 · cited 2×
“tonic–clonic seizures show multilobar hyperfusion (17,28) and could represent failure of this ictal surround inhibition.”
Background
Cited by
Angiogenesis is associated with blood-brain barrier permeability in temporal lobe epilepsy
Rigau, V., Morin, M., Rousset, M.-C., de Bock, F., Lebrun, A., Coubes, P., Picot, M.-C., Baldy-Moulinier, M., Bockaert, J., Crespel, A., et al. (2007) · Brain · doi:10.1093/brain/awm118 · Cited by 429
A neuroradiologist’s guide to arterial spin labeling MRI in clinical practice
Grade, M., Hernandez Tamames, J. A., Pizzini, F. B., Achten, E., Golay, X., & Smits, M. (2015) · Neuroradiology · doi:10.1007/s00234-015-1571-z · Cited by 298
PET and SPECT in epilepsy: a critical review.
la Fougère, C., Rominger, A., Förster, S., Geisler, J., & Bartenstein, P. (2009) · Epilepsy & Behavior · doi:10.1016/j.yebeh.2009.02.025 · Cited by 224
Differentiating between nonepileptic and epileptic seizures
Devinsky, O., Gazzola, D., & LaFrance, W. C. (2011) · Nature Reviews Neurology · doi:10.1038/nrneurol.2011.24 · Cited by 194
Tyvaert, L., Hawco, C., Kobayashi, E., LeVan, P., Dubeau, F., & Gotman, J. (2008) · Brain · doi:10.1093/brain/awn145 · Cited by 171
Neuroimaging during Trance State: A Contribution to the Study of Dissociation
Peres, J. F., Moreira-Almeida, A., Caixeta, L., Leao, F., & Newberg, A. (2012) · PLoS ONE · doi:10.1371/journal.pone.0049360 · Cited by 105
Cerebral perfusion abnormality in narcolepsy with cataplexy
Yeon Joo, E., Hong, S. B., Tae, W. S., Kim, J. H., Han, S. J., Cho, Y. W., Yoon, C. H., Lee, S. I., Lee, M. H., Lee, K. H., et al. (2005) · NeuroImage · doi:10.1016/j.neuroimage.2005.06.019 · Cited by 90
Metadata
- Authors
- Van Paesschen, W.
- Venue
- Epilepsia
- Publisher
- Wiley
- Published
- 2004-07
- Volume
- 45
- Issue
- s4
- Pages
- 35-40
- ISSN
- 0013-9580 (ISSN-L)
- 1528-1167
- OpenAlex
- W3192789958
- Cited by
- 183
- References
- 22
- FWCI
- 4.63
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.