The DOI matches its Crossref record.
Phase‐retrieved pupil functions in wide‐field fluorescence microscopy
Abstract
Summary: Pupil functions are compact and modifiable descriptions of the three‐dimensional (3D) imaging properties of wide‐field optical systems. The pupil function of a microscope can be computationally estimated from the measured point spread function (PSF) using phase retrieval algorithms. The compaction of a 3D PSF into a 2D pupil function suppresses artefacts and measurement noise without resorting to rotational averaging. We show here that such ‘phase‐retrieved’ pupil functions can reproduce features in the optical path, both near the sample and in the microscope. Unlike the PSF, the pupil function can be easily modified to include known aberrations, such as those induced by index‐mismatched mounting media, simply by multiplying the pupil function by a calculated aberration function. PSFs calculated from such a modified pupil function closely match the corresponding measured PSFs collected under the aberrated imaging conditions. When used for image deconvolution of simulated objects, these phase‐retrieved, calculated PSFs perform similarly to directly measured PSFs.
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cited by
Ultra-High Resolution Imaging by Fluorescence Photoactivation Localization Microscopy
Hess, S. T., Girirajan, T. P. K., & Mason, M. D. (2006) · Biophysical Journal · doi:10.1529/biophysj.106.091116 · Cited by 3,605
Measuring image resolution in optical nanoscopy
Nieuwenhuizen, R. P. J., Lidke, K. A., Bates, M., Puig, D. L., Grünwald, D., Stallinga, S., & Rieger, B. (2013) · Nature Methods · doi:10.1038/nmeth.2448 · Cited by 800
Adaptive optical fluorescence microscopy
Ji, N. (2017) · Nature Methods · doi:10.1038/nmeth.4218 · Cited by 527
Fast, single-molecule localization that achieves theoretically minimum uncertainty
Smith, C. S., Joseph, N., Rieger, B., & Lidke, K. A. (2010) · Nature Methods · doi:10.1038/nmeth.1449 · Cited by 522
Precisely and accurately localizing single emitters in fluorescence microscopy
Deschout, H., Zanacchi, F. C., Mlodzianoski, M., Diaspro, A., Bewersdorf, J., Hess, S. T., & Braeckmans, K. (2014) · Nature Methods · doi:10.1038/nmeth.2843 · Cited by 498
Metadata
- Authors
- HANSER, B. M., GUSTAFSSON, M. G. L., AGARD, D. A., & SEDAT, J. W.
- Venue
- Journal of Microscopy
- Publisher
- Wiley
- Published
- 2004-09-15
- Volume
- 216
- Issue
- 1
- Pages
- 32-48
- ISSN
- 0022-2720 (ISSN-L)
- 1365-2818
- OpenAlex
- W2062841564
- Cited by
- 163
- References
- 0
- FWCI
- 2.22
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Phase‐retrieved pupil functions in wide‐field fluorescence microscopy. https://app.cochat.ai/papers/10.1111/j.0022-2720.2004.01393.x
- The paper
- HANSER, B. M., GUSTAFSSON, M. G. L., AGARD, D. A., & SEDAT, J. W. (2004). Phase‐retrieved pupil functions in wide‐field fluorescence microscopy. Journal of Microscopy. https://doi.org/10.1111/j.0022-2720.2004.01393.x
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.