Phase‐retrieved pupil functions in wide‐field fluorescence microscopy
The DOI matches its Crossref record; 2 of the 2 references it cites were found in a registry or an index.
Abstract
Summary: Pupil functions are compact and modifiable descriptions of the three‐dimensional (3D) imaging properties of wide‐field optical systems. The pupil function of a microscope can be computationally estimated from the measured point spread function (PSF) using phase retrieval algorithms. The compaction of a 3D PSF into a 2D pupil function suppresses artefacts and measurement noise without resorting to rotational averaging. We show here that such ‘phase‐retrieved’ pupil functions can reproduce features in the optical path, both near the sample and in the microscope. Unlike the PSF, the pupil function can be easily modified to include known aberrations, such as those induced by index‐mismatched mounting media, simply by multiplying the pupil function by a calculated aberration function. PSFs calculated from such a modified pupil function closely match the corresponding measured PSFs collected under the aberrated imaging conditions. When used for image deconvolution of simulated objects, these phase‐retrieved, calculated PSFs perform similarly to directly measured PSFs.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Richards, B., & Wolf, E. (1959) · Proceedings of the Royal Society of London. Series A. Mathematical and Physical Sciences · doi:10.1098/rspa.1959.0200 · Cited by 3,095 · cited 2×
“…(cos(θ) − 1) sin(ϕ) cos(ϕ) Py→Ey: cos(θ) sin2(ϕ) + cos2(ϕ) (3) Pz→Ex: sin(θ) cos(ϕ) Pz→Ey: sin(θ) sin(ϕ) These are the same trigonometric functions as appear in the classic calculation by Richards & Wolf (1959) of focused vectorial light fields – the two approaches are in fact equivalent.”
MethodAberration correction for confocal imaging in refractive‐index‐mismatched media
Booth, M. J., Neil, M. A. A., & Wilson, T. (1998) · Journal of Microscopy · doi:10.1111/j.1365-2818.1998.99999.x · Cited by 248
Cited by
Ultra-High Resolution Imaging by Fluorescence Photoactivation Localization Microscopy
Hess, S. T., Girirajan, T. P. K., & Mason, M. D. (2006) · Biophysical Journal · doi:10.1529/biophysj.106.091116 · Cited by 3,605
Measuring image resolution in optical nanoscopy
Nieuwenhuizen, R. P. J., Lidke, K. A., Bates, M., Puig, D. L., Grünwald, D., Stallinga, S., & Rieger, B. (2013) · Nature Methods · doi:10.1038/nmeth.2448 · Cited by 800
Adaptive optical fluorescence microscopy
Ji, N. (2017) · Nature Methods · doi:10.1038/nmeth.4218 · Cited by 527
Fast, single-molecule localization that achieves theoretically minimum uncertainty
Smith, C. S., Joseph, N., Rieger, B., & Lidke, K. A. (2010) · Nature Methods · doi:10.1038/nmeth.1449 · Cited by 522
Precisely and accurately localizing single emitters in fluorescence microscopy
Deschout, H., Zanacchi, F. C., Mlodzianoski, M., Diaspro, A., Bewersdorf, J., Hess, S. T., & Braeckmans, K. (2014) · Nature Methods · doi:10.1038/nmeth.2843 · Cited by 498
von Diezmann, L., Shechtman, Y., & Moerner, W. E. (2017) · Chemical Reviews · doi:10.1021/acs.chemrev.6b00629 · Cited by 491
Optimal Point Spread Function Design for 3D Imaging
Shechtman, Y., Sahl, S. J., Backer, A. S., & Moerner, W. E. (2014) · Physical Review Letters · doi:10.1103/physrevlett.113.133902 · Cited by 384
Sage, D., Pham, T.-A., Babcock, H., Lukes, T., Pengo, T., Chao, J., Velmurugan, R., Herbert, A., Agrawal, A., Colabrese, S., et al. (2019) · Nature Methods · doi:10.1038/s41592-019-0364-4 · Cited by 333
Shechtman, Y., Weiss, L. E., Backer, A. S., Sahl, S. J., & Moerner, W. E. (2015) · Nano Letters · doi:10.1021/acs.nanolett.5b01396 · Cited by 270
I5S: Wide-Field Light Microscopy with 100-nm-Scale Resolution in Three Dimensions
Shao, L., Isaac, B., Uzawa, S., Agard, D. A., Sedat, J. W., & Gustafsson, M. G. L. (2008) · Biophysical Journal · doi:10.1529/biophysj.107.120352 · Cited by 169
“1. Calculating an ideal theoretical detection PSF using a vectorial imaging model ( 25 ), assuming a single wavelength and an NA of 1.35, which best matched the observations.”
MethodInfluentialSelf-citationFast and accurate sCMOS noise correction for fluorescence microscopy
Mandracchia, B., Hua, X., Guo, C., Son, J., Urner, T., & Jia, S. (2020) · Nature Communications · doi:10.1038/s41467-019-13841-8 · Cited by 161
Saffarian, S., & Kirchhausen, T. (2008) · Biophysical Journal · doi:10.1529/biophysj.107.117234 · Cited by 111
Deep learning-driven adaptive optics for single-molecule localization microscopy
Zhang, P., Ma, D., Cheng, X., Tsai, A. P., Tang, Y., Gao, H.-C., Fang, L., Bi, C., Landreth, G. E., Chubykin, A. A., et al. (2023) · Nature Methods · doi:10.1038/s41592-023-02029-0 · Cited by 42
Metadata
- Authors
- HANSER, B. M., GUSTAFSSON, M. G. L., AGARD, D. A., & SEDAT, J. W.
- Venue
- Journal of Microscopy
- Publisher
- Wiley
- Published
- 2004-09-15
- Volume
- 216
- Issue
- 1
- Pages
- 32-48
- ISSN
- 0022-2720 (ISSN-L)
- 1365-2818
- OpenAlex
- W2062841564
- Cited by
- 163
- References
- 2
- FWCI
- 2.22
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.