The DOI matches its Crossref record; 17 of the 17 references it cites were found in a registry or an index.
Biomimetic Hydroxyapatite Coating on Metal Implants
Open accessAbstract
The combination of the high mechanical strength of metals with the osteoconductive properties of calcium phosphates make hydroxyapatite coatings on titanium implants widely used in orthopedic surgery. However, the most popular coating method, plasma spraying, exhibits some important drawbacks: the inability to cover porous implants and to incorporate biologically active agents, delamination, and particle release. The aim of this study was to elaborate a dense, strong, and thick calcium‐phosphate coating on titanium and porous‐tantalum implants using a two‐step biomimetic procedure. In the first step, the implants were soaked in a solution that was 5 times more concentrated than regular simulated body fluid (SBF‐A solution). A thin but uniform amorphous calcium‐phosphate coating was deposited on the metal. Then, the implants were immersed in the SBF‐B solution, which had a similar composition as the SBF‐A solution, but with decreased contents of crystal growth inhibitors (i.e., Mg 2+ and HCO 3 − ). This resulted in the fast precipitation of a 30 μm thick crystalline calcium‐phosphate coating. The pH of the SBF‐B solution and the thickness of the crystalline coating layer were studied as a function of time. The Fourier transform infrared spectra and X‐ray diffraction patterns showed that this new coating closely resembles bone mineral. Our biomimetic coating should facilitate rapid bone formation around the implant, reducing therewith the patient's recovery time after surgery.
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Solutions able to reproduce in vivo surface‐structure changes in bioactive glass‐ceramic A‐W3
Kokubo, T., Kushitani, H., Sakka, S., Kitsugi, T., & Yamamuro, T. (1990) · Journal of Biomedical Materials Research · doi:10.1002/jbm.820240607 · Cited by 3,836
Structure and Chemistry of the Apatites and Other Calcium Orthophosphates
(1994) · Studies in Inorganic Chemistry · doi:10.1016/c2009-0-10247-7 · Cited by 2,527
Calcium phosphates in oral biology and medicine.
LeGeros, R. Z. (1991) · PubMed · Cited by 1,469
Preparation of bioactive Ti and its alloys via simple chemical surface treatment
Kim, H.-M., Miyaji, F., Kokubo, T., & Nakamura, T. (1996) · Journal of Biomedical Materials Research · doi:10.1002/(sici)1097-4636(199611)32:3<409::aid-jbm14>3.0.co;2-b · Cited by 1,005
Structural analysis of hydroxyapatite coatings on titanium
Ducheyne, P., Raemdonck, W. V., Heughebaert, J. C., & Heughebaert, M. (1986) · Biomaterials · doi:10.1016/0142-9612(86)90063-3 · Cited by 421
Crystallization of calcium phosphates. A constant composition study
Koutsoukos, P., Amjad, Z., Tomson, M. B., & Nancollas, G. H. (1980) · Journal of the American Chemical Society · doi:10.1021/ja00525a015 · Cited by 412
Bonelike Hydroxyapatite Induction by a Gel‐Derived Titania on a Titanium Substrate
Li, P., Kangasniemi, I., de Groot, K., & Kokubo, T. (1994) · Journal of the American Ceramic Society · doi:10.1111/j.1151-2916.1994.tb05407.x · Cited by 344
Self-citationAn evaluation of variables influencing implant fixation by direct bone apposition
Thomas, K. A., & Cook, S. D. (1985) · Journal of Biomedical Materials Research · doi:10.1002/jbm.820190802 · Cited by 313
Magnesium stabilization of amorphous calcium phosphate: A kinetic study
Boskey, A. L., & Posner, A. S. (1974) · Materials Research Bulletin · doi:10.1016/0025-5408(74)90169-x · Cited by 273
Crystal growth of calcium phosphates in the presence of magnesium ions
Salimi, M. H., Heughebaert, J. C., & Nancollas, G. H. (1985) · Langmuir · doi:10.1021/la00061a019 · Cited by 237
Cited by
Magnesium and its alloys as orthopedic biomaterials: A review
Staiger, M. P., Pietak, A. M., Huadmai, J., & Dias, G. (2006) · Biomaterials · doi:10.1016/j.biomaterials.2005.10.003 · Cited by 4,452
Surface treatments of titanium dental implants for rapid osseointegration
Le Guéhennec, L., Soueidan, A., Layrolle, P., & Amouriq, Y. (2007) · Dental Materials · doi:10.1016/j.dental.2006.06.025 · Cited by 2,406
Self-citationCalcium phosphates as substitution of bone tissues
VALLETREGI, M. (2004) · Progress in Solid State Chemistry · doi:10.1016/j.progsolidstchem.2004.07.001 · Cited by 1,160
Bose, S., & Tarafder, S. (2012) · Acta Biomaterialia · doi:10.1016/j.actbio.2011.11.017 · Cited by 958
Biodegradable Materials for Bone Repair and Tissue Engineering Applications
Sheikh, Z., Najeeb, S., Khurshid, Z., Verma, V., Rashid, H., & Glogauer, M. (2015) · Materials · doi:10.3390/ma8095273 · Cited by 782
Metadata
- Authors
- Habibovic, P., Barrère, F., Van Blitterswijk, C. A., de Groot, K., & Layrolle, P.
- Venue
- Journal of the American Ceramic Society
- Publisher
- Wiley
- Published
- 2002-03
- Volume
- 85
- Issue
- 3
- Pages
- 517-522
- ISSN
- 0002-7820 (ISSN-L)
- 1551-2916
- OpenAlex
- W2135662492
- Cited by
- 548
- References
- 17
- FWCI
- 13.22
- Type
- journal article
- Language
- en
- Open access
- green
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Biomimetic Hydroxyapatite Coating on Metal Implants. https://app.cochat.ai/papers/10.1111/j.1151-2916.2002.tb00126.x
- The paper
- Habibovic, P., Barrère, F., Van Blitterswijk, C. A., de Groot, K., & Layrolle, P. (2002). Biomimetic Hydroxyapatite Coating on Metal Implants. Journal of the American Ceramic Society. https://doi.org/10.1111/j.1151-2916.2002.tb00126.x
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.