Biomimetic Hydroxyapatite Coating on Metal Implants
Open accessThe DOI matches its Crossref record; 17 of the 17 references it cites were found in a registry or an index.
Abstract
The combination of the high mechanical strength of metals with the osteoconductive properties of calcium phosphates make hydroxyapatite coatings on titanium implants widely used in orthopedic surgery. However, the most popular coating method, plasma spraying, exhibits some important drawbacks: the inability to cover porous implants and to incorporate biologically active agents, delamination, and particle release. The aim of this study was to elaborate a dense, strong, and thick calcium‐phosphate coating on titanium and porous‐tantalum implants using a two‐step biomimetic procedure. In the first step, the implants were soaked in a solution that was 5 times more concentrated than regular simulated body fluid (SBF‐A solution). A thin but uniform amorphous calcium‐phosphate coating was deposited on the metal. Then, the implants were immersed in the SBF‐B solution, which had a similar composition as the SBF‐A solution, but with decreased contents of crystal growth inhibitors (i.e., Mg 2+ and HCO 3 − ). This resulted in the fast precipitation of a 30 μm thick crystalline calcium‐phosphate coating. The pH of the SBF‐B solution and the thickness of the crystalline coating layer were studied as a function of time. The Fourier transform infrared spectra and X‐ray diffraction patterns showed that this new coating closely resembles bone mineral. Our biomimetic coating should facilitate rapid bone formation around the implant, reducing therewith the patient's recovery time after surgery.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Solutions able to reproduce in vivo surface‐structure changes in bioactive glass‐ceramic A‐W3
Kokubo, T., Kushitani, H., Sakka, S., Kitsugi, T., & Yamamuro, T. (1990) · Journal of Biomedical Materials Research · doi:10.1002/jbm.820240607 · Cited by 3,836
Structure and Chemistry of the Apatites and Other Calcium Orthophosphates
(1994) · Studies in Inorganic Chemistry · doi:10.1016/c2009-0-10247-7 · Cited by 2,527
Calcium phosphates in oral biology and medicine.
LeGeros, R. Z. (1991) · PubMed · Cited by 1,852
Preparation of bioactive Ti and its alloys via simple chemical surface treatment
Kim, H.-M., Miyaji, F., Kokubo, T., & Nakamura, T. (1996) · Journal of Biomedical Materials Research · doi:10.1002/(sici)1097-4636(199611)32:3<409::aid-jbm14>3.0.co;2-b · Cited by 1,005
Structural analysis of hydroxyapatite coatings on titanium
Ducheyne, P., Raemdonck, W. V., Heughebaert, J. C., & Heughebaert, M. (1986) · Biomaterials · doi:10.1016/0142-9612(86)90063-3 · Cited by 421
Crystallization of calcium phosphates. A constant composition study
Koutsoukos, P., Amjad, Z., Tomson, M. B., & Nancollas, G. H. (1980) · Journal of the American Chemical Society · doi:10.1021/ja00525a015 · Cited by 412
Bonelike Hydroxyapatite Induction by a Gel‐Derived Titania on a Titanium Substrate
Li, P., Kangasniemi, I., de Groot, K., & Kokubo, T. (1994) · Journal of the American Ceramic Society · doi:10.1111/j.1151-2916.1994.tb05407.x · Cited by 344
An evaluation of variables influencing implant fixation by direct bone apposition
Thomas, K. A., & Cook, S. D. (1985) · Journal of Biomedical Materials Research · doi:10.1002/jbm.820190802 · Cited by 313
Magnesium stabilization of amorphous calcium phosphate: A kinetic study
Boskey, A. L., & Posner, A. S. (1974) · Materials Research Bulletin · doi:10.1016/0025-5408(74)90169-x · Cited by 273
Crystal growth of calcium phosphates in the presence of magnesium ions
Salimi, M. H., Heughebaert, J. C., & Nancollas, G. H. (1985) · Langmuir · doi:10.1021/la00061a019 · Cited by 237
Cited by
Magnesium and its alloys as orthopedic biomaterials: A review
Staiger, M. P., Pietak, A. M., Huadmai, J., & Dias, G. (2006) · Biomaterials · doi:10.1016/j.biomaterials.2005.10.003 · Cited by 4,452
Surface treatments of titanium dental implants for rapid osseointegration
Le Guéhennec, L., Soueidan, A., Layrolle, P., & Amouriq, Y. (2007) · Dental Materials · doi:10.1016/j.dental.2006.06.025 · Cited by 2,406
Self-citationCalcium phosphates as substitution of bone tissues
VALLETREGI, M. (2004) · Progress in Solid State Chemistry · doi:10.1016/j.progsolidstchem.2004.07.001 · Cited by 1,160
Biomimetic Systems for Hydroxyapatite Mineralization Inspired By Bone and Enamel
Palmer, L. C., Newcomb, C. J., Kaltz, S. R., Spoerke, E. D., & Stupp, S. I. (2008) · Chemical Reviews · doi:10.1021/cr8004422 · Cited by 1,090
Bose, S., & Tarafder, S. (2012) · Acta Biomaterialia · doi:10.1016/j.actbio.2011.11.017 · Cited by 958
Biodegradable Materials for Bone Repair and Tissue Engineering Applications
Sheikh, Z., Najeeb, S., Khurshid, Z., Verma, V., Rashid, H., & Glogauer, M. (2015) · Materials · doi:10.3390/ma8095273 · Cited by 782
Engineering biocompatible implant surfaces
Bauer, S., Schmuki, P., von der Mark, K., & Park, J. (2013) · Progress in Materials Science · doi:10.1016/j.pmatsci.2012.09.001 · Cited by 780
Amorphous calcium phosphates: Synthesis, properties and uses in biomaterials
Combes, C., & Rey, C. (2010) · Acta Biomaterialia · doi:10.1016/j.actbio.2010.02.017 · Cited by 752
Significance of calcium phosphate coatings for the enhancement of new bone osteogenesis – A review
Surmenev, R. A., Surmeneva, M. A., & Ivanova, A. A. (2014) · Acta Biomaterialia · doi:10.1016/j.actbio.2013.10.036 · Cited by 712
Yang, Y., Kim, K.-H., & Ong, J. L. (2005) · Biomaterials · doi:10.1016/j.biomaterials.2004.02.029 · Cited by 667
Calcium phosphate coatings on magnesium alloys for biomedical applications: A review
Shadanbaz, S., & Dias, G. J. (2012) · Acta Biomaterialia · doi:10.1016/j.actbio.2011.10.016 · Cited by 651
Amorphous calcium (ortho)phosphates
Dorozhkin, S. V. (2010) · Acta Biomaterialia · doi:10.1016/j.actbio.2010.06.031 · Cited by 485
Stigter, M., Bezemer, J., de Groot, K., & Layrolle, P. (2004) · Journal of Controlled Release · doi:10.1016/j.jconrel.2004.06.011 · Cited by 446
Self-citationAn algorithm-based topographical biomaterials library to instruct cell fate
Unadkat, H. V., Hulsman, M., Cornelissen, K., Papenburg, B. J., Truckenmüller, R. K., Carpenter, A. E., Wessling, M., Post, G. F., Uetz, M., Reinders, M. J. T., et al. (2011) · Proceedings of the National Academy of Sciences · doi:10.1073/pnas.1109861108 · Cited by 379
Self-citationTitanium Coatings and Surface Modifications: Toward Clinically Useful Bioactive Implants
Civantos, A., Martínez-Campos, E., Ramos, V., Elvira, C., Gallardo, A., & Abarrategi, A. (2017) · ACS Biomaterials Science & Engineering · doi:10.1021/acsbiomaterials.6b00604 · Cited by 338
Calcium orthophosphate-based biocomposites and hybrid biomaterials
Dorozhkin, S. V. (2009) · Journal of Materials Science · doi:10.1007/s10853-008-3124-x · Cited by 300
Calcium orthophosphate deposits: Preparation, properties and biomedical applications
Dorozhkin, S. V. (2015) · Materials Science and Engineering: C · doi:10.1016/j.msec.2015.05.033 · Cited by 298
Yang, F., Wolke, J. G. C., & Jansen, J. A. (2008) · Chemical Engineering Journal · doi:10.1016/j.cej.2007.07.076 · Cited by 297
Fabrication, Properties and Applications of Dense Hydroxyapatite: A Review
Prakasam, M., Locs, J., Salma-Ancane, K., Loca, D., Largeteau, A., & Berzina-Cimdina, L. (2015) · Journal of Functional Biomaterials · doi:10.3390/jfb6041099 · Cited by 295
Calcium Orthophosphates as Bioceramics: State of the Art
Dorozhkin, S. V. (2010) · Journal of Functional Biomaterials · doi:10.3390/jfb1010022 · Cited by 278
Barrère, F., van der Valk, C. M., Meijer, G., Dalmeijer, R. A. J., de Groot, K., & Layrolle, P. (2003) · Journal of Biomedical Materials Research Part B: Applied Biomaterials · doi:10.1002/jbm.b.10057 · Cited by 274
Self-citationNanophase Hydroxyapatite as a Biomaterial in Advanced Hard Tissue Engineering: A Review
Zakaria, S. M., Sharif Zein, S. H., Othman, M. R., Yang, F., & Jansen, J. A. (2013) · Tissue Engineering Part B: Reviews · doi:10.1089/ten.teb.2012.0624 · Cited by 252
Osteogenecity of octacalcium phosphate coatings applied on porous metal implants
Barrère, F., van der Valk, C. M., Dalmeijer, R. A. J., Meijer, G., van Blitterswijk, C. A., de Groot, K., & Layrolle, P. (2003) · Journal of Biomedical Materials Research Part A · doi:10.1002/jbm.a.10454 · Cited by 248
Self-citationMetals for Biomedical Applications
Hermawan, H., Ramdan, D., & P. Djuansjah, J. R. (2011) · Biomedical Engineering - From Theory to Applications · doi:10.5772/19033 · Cited by 238
“17 Metals for Biomedical Applications Hendra Hermawan, Dadan Ramdan and Joy R. P. Djuansjah Faculty of Biomedical Engineering and Health Science, Universiti Teknologi Malaysia Malaysia”
BackgroundGu, Y. W., Khor, K. A., & Cheang, P. (2003) · Biomaterials · doi:10.1016/s0142-9612(02)00573-2 · Cited by 234
Tas, A. C., & Bhaduri, S. B. (2004) · Journal of Materials Research · doi:10.1557/jmr.2004.0349 · Cited by 232
Biological performance of uncoated and octacalcium phosphate-coated Ti6Al4V
Habibovic, P., Li, J., van der Valk, C. M., Meijer, G., Layrolle, P., van Blitterswijk, C. A., & de Groot, K. (2005) · Biomaterials · doi:10.1016/j.biomaterials.2004.02.026 · Cited by 222
Self-citationBiocomposites and hybrid biomaterials based on calcium orthophosphates
Dorozhkin, S. V. (2011) · Biomatter · doi:10.4161/biom.1.1.16782 · Cited by 198
Preparation of poly(lactic acid) composites containing calcium carbonate (vaterite)
Kasuga, T., Maeda, H., Kato, K., Nogami, M., Hata, K.-I., & Ueda, M. (2003) · Biomaterials · doi:10.1016/s0142-9612(03)00190-x · Cited by 191
“[7]).”
Nano-scale study of the nucleation and growth of calcium phosphate coating on titanium implants
Barrere, F., Snel, M. M. E., van Blitterswijk, C. A., de Groot, K., & Layrolle, P. (2004) · Biomaterials · doi:10.1016/j.biomaterials.2003.09.063 · Cited by 177
“The presence of an interface composed of very small entities may create an efficient adhesion of the final Ca-P coating and favour secondary nucleation of calcium phosphate [8,9,11,13,16].”
BackgroundMethodResultSelf-citationLiu, Z., Liu, X., & Ramakrishna, S. (2021) · Biotechnology Journal · doi:10.1002/biot.202000116 · Cited by 165
Review of Functionally Graded Thermal Sprayed Coatings
Łatka, L., Pawłowski, L., Winnicki, M., Sokołowski, P., Małachowska, A., & Kozerski, S. (2020) · Applied Sciences · doi:10.3390/app10155153 · Cited by 163
Controlled M1-to-M2 transition of aged macrophages by calcium phosphate coatings
Alhamdi, J. R., Peng, T., Al-Naggar, I. M., Hawley, K. L., Spiller, K. L., & Kuhn, L. T. (2019) · Biomaterials · doi:10.1016/j.biomaterials.2018.07.012 · Cited by 110
Lin, B., Zhong, M., Zheng, C., Cao, L., Wang, D., Wang, L., Liang, J., & Cao, B. (2015) · Surface and Coatings Technology · doi:10.1016/j.surfcoat.2015.09.033 · Cited by 106
Gelatin functionalised porous titanium alloy implants for orthopaedic applications
Vanderleyden, E., Van Bael, S., Chai, Y. C., Kruth, J.-P., Schrooten, J., & Dubruel, P. (2014) · Materials Science and Engineering: C · doi:10.1016/j.msec.2014.05.048 · Cited by 45
Metadata
- Authors
- Habibovic, P., Barrère, F., Van Blitterswijk, C. A., de Groot, K., & Layrolle, P.
- Venue
- Journal of the American Ceramic Society
- Publisher
- Wiley
- Published
- 2002-03
- Volume
- 85
- Issue
- 3
- Pages
- 517-522
- ISSN
- 0002-7820 (ISSN-L)
- 1551-2916
- OpenAlex
- W2135662492
- Cited by
- 548
- References
- 17
- FWCI
- 13.22
- Type
- journal article
- Language
- en
- Open access
- green
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.