The DOI matches its Crossref record; 31 of the 31 references it cites were found in a registry or an index.
On the Cyto‐Toxicity Caused by Quantum Dots
Abstract
Quantum dots (QDs) such as CdSe QDs have been introduced as new fluorophores. The QDs conjugated with antibody are starting to be widely used for immunostaining. However there is still not sufficient analysis of the toxicity of QDs in the literature. Therefore we evaluated the cell damage caused by the quantum dots for biological applications. We performed cell viability assay to determine the difference in cell damage depending on the sizes and colors of mercapto‐undecanoic acid (MUA) QDs and the cell types. The results showed that the cell viability decreased with increasing concentration of MUA‐QDs. But in the case of Vero cell (African green monkey's kidney cell) with red fluorescence QD (QD640), the cell damage was less than for the others. Furthermore through the flow cytometry assay we found that this cell damage caused by MUA‐QD turned out to be cell death after 4‐6‐hr incubation. From the two assays described above, we found that there is a range of concentration of MUA‐QDs where the cell viability decreased without cell death occurring and thus we conclude that attention should be given when MUA‐QDs are applied to living organisms even in low concentrations.
Overview
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
Citations
Cites
Mosmann, T. (1983) · Journal of Immunological Methods · doi:10.1016/0022-1759(83)90303-4 · Cited by 56,104
Kubo, R. (1957) · Journal of the Physical Society of Japan · doi:10.1143/jpsj.12.570 · Cited by 9,441
Murray, C. B., Norris, D. J., & Bawendi, M. G. (1993) · Journal of the American Chemical Society · doi:10.1021/ja00072a025 · Cited by 9,334
Semiconductor Nanocrystals as Fluorescent Biological Labels
Bruchez, M. P., Moronne, M. M., Gin, P., Weiss, S., & Alivisatos, A. P. (1998) · Science · doi:10.1126/science.281.5385.2013 · Cited by 8,614
Quantum Dot Bioconjugates for Ultrasensitive Nonisotopic Detection
Chan, W. C. W., & Nie, S. (1998) · Science · doi:10.1126/science.281.5385.2016 · Cited by 7,284
Dabbousi, B. O., Rodriguez-Viejo, J., Mikulec, F. V., Heine, J. R., Mattoussi, H., Ober, R., Jensen, K. F., & Bawendi, M. G. (1997) · The Journal of Physical Chemistry B · doi:10.1021/jp971091y · Cited by 4,229
In Vivo Imaging of Quantum Dots Encapsulated in Phospholipid Micelles
Dubertret, B., Skourides, P., Norris, D. J., Noireaux, V., Brivanlou, A. H., & Libchaber, A. (2002) · Science · doi:10.1126/science.1077194 · Cited by 3,019
Synthesis and Characterization of Strongly Luminescing ZnS-Capped CdSe Nanocrystals
Hines, M. A., & Guyot‐Sionnest, P. (1996) · The Journal of Physical Chemistry · doi:10.1021/jp9530562 · Cited by 2,915
Electroluminescence from single monolayers of nanocrystals in molecular organic devices
Coe-Sullivan, S. A., Woo, W.-K., Bawendi, M. G., & Bulović, V. (2002) · Nature · doi:10.1038/nature01217 · Cited by 2,609
Wu, X., Liu, H., Liu, J., Haley, K. N., Treadway, J. A., Larson, J., Ge, N., Peale, F., & Bruchez, M. P. (2002) · Nature Biotechnology · doi:10.1038/nbt764 · Cited by 2,506
Quantum Dot Superlattice Thermoelectric Materials and Devices
Harman, T. C., Taylor, P., Walsh, M., & LaForge, B. E. (2002) · Science · doi:10.1126/science.1072886 · Cited by 2,498
Peng, X., Schlamp, M. C., Kadavanich, A. V., & Alivisatos, A. P. (1997) · Journal of the American Chemical Society · doi:10.1021/ja970754m · Cited by 2,420
Generalized Cumulant Expansion Method
Kubo, R. (1962) · Journal of the Physical Society of Japan · doi:10.1143/jpsj.17.1100 · Cited by 1,792
Indistinguishable photons from a single-photon device
Santori, C., Fattal, D., Vučković, J., Solomon, G. S., & Yamamoto, Y. (2002) · Nature · doi:10.1038/nature01086 · Cited by 1,559
Gerion, D., Pinaud, F. F., Williams, S. C., Parak, W. J., Zanchet, D., Weiss, S., & Alivisatos, A. P. (2001) · The Journal of Physical Chemistry B · doi:10.1021/jp0105488 · Cited by 1,270
Stochastic Liouville Equations
Kubo, R. (1963) · Journal of Mathematical Physics · doi:10.1063/1.1703941 · Cited by 1,019
An All-Optical Quantum Gate in a Semiconductor Quantum Dot
Li, X., Wu, Y., Steel, D. G., Gammon, D., Stievater, T. H., Katzer, D. S., Park, D., Piermarocchi, C., & Sham, L. J. (2003) · Science · doi:10.1126/science.1083800 · Cited by 905
Coherent properties of a two-level system based on a quantum-dot photodiode
Zrenner, A., Beham, E., Stufler, S., Findeis, F., Bichler, M., & Abstreiter, G. (2002) · Nature · doi:10.1038/nature00912 · Cited by 775
A water-soluble tetrazolium salt useful for colorimetric cell viability assay
Tominaga, H., Ishiyama, M., Ohseto, F., Sasamoto, K., Hamamoto, T., Suzuki, K., & Watanabe, M. (1999) · Analytical Communications · doi:10.1039/a809656b · Cited by 723
Self-citationIshiyama, M. (1997) · Talanta · doi:10.1016/s0039-9140(97)00017-9 · Cited by 694
Rho GTPases are over-expressed in human tumors
Fritz, G., Just, I., & Kaina, B. (1999) · International Journal of Cancer · doi:10.1002/(sici)1097-0215(19990531)81:5 · Cited by 671
Targeting Cell Surface Receptors with Ligand-Conjugated Nanocrystals
Rosenthal, S. J., Tomlinson, I. D., Adkins, E. M., Schroeter, S., Adams, S. V., Swafford, L. A., McBride, J. R., Wang, Y., DeFelice, L. J., & Blakely, R. (2002) · Journal of the American Chemical Society · doi:10.1021/ja003486s · Cited by 344
Semiconductor quantum dot/albumin complex is a long-life and highly photostable endosome marker
Hanaki, K., Momo, A., Oku, T., et al. (2003) · Biochemical and Biophysical Research Communications · doi:10.1016/s0006-291x(03)00211-0 · Cited by 324
Self-citationMultiplexed SNP genotyping using the QbeadTM system: a quantum dot-encoded microsphere-based assay
Xu, H. (2003) · Nucleic Acids Research · doi:10.1093/nar/gng043 · Cited by 270
Cadmium induces apoptosis partly via caspase-9 activation in HL-60 cells
Kondoh, M., Araragi, S., Sato, K., et al. (2002) · Toxicology · doi:10.1016/s0300-483x(01)00536-4 · Cited by 185
Viability assessment of honey bee, Apis mellifera, sperm using dual fluorescent staining
Collins, A. M., & Donoghue, A. M. (1999) · Theriogenology · doi:10.1016/s0093-691x(99)00094-1 · Cited by 141
Elstein, K. H., & Zucker, R. M. (1994) · Experimental Cell Research · doi:10.1006/excr.1994.1094 · Cited by 140
Seydel, C. (2003) · Science · doi:10.1126/science.300.5616.80 · Cited by 116
Shubeita, G. T., Sekatskii, S. K., Dietler, G., et al. (2003) · Journal of Microscopy · doi:10.1046/j.1365-2818.2003.01143.x · Cited by 50
Turnover and Down‐Regulation of GABAA Receptor α1, β2S, and γ1 Subunit mRNAs by Neurons in Culture
Lyons, H. R., Gibbs, T. T., & Farb, D. H. (2000) · Journal of Neurochemistry · doi:10.1046/j.1471-4159.2000.0741041.x · Cited by 47
Shatrova, A. N., Aksenov, N., Poletaev, A. I., et al. (2003) · PubMed · Cited by 2
Cited by
Sorted by citations
Drug delivery and nanoparticles: Applications and hazards
de Jong (2008) · International Journal of Nanomedicine · doi:10.2147/ijn.s596 · Cited by 3,854
“In vitro studies have indicated that quantum dots may be toxic (Hoshino et al 2004; Shiohara et al 2004; Lovric, Bazzi et al 2005) of which some toxicity could be attributed to the surface coating (Hoshino et al 2004, 2007).”
BackgroundLewinski, N. A., Colvin, V. L., & Drezek, R. A. (2007) · Small · doi:10.1002/smll.200700595 · Cited by 2,876
A Toxicologic Review of Quantum Dots: Toxicity Depends on Physicochemical and Environmental Factors
Hardman, R. C. (2005) · Environmental Health Perspectives · doi:10.1289/ehp.8284 · Cited by 2,304
“QD-induced cytotoxicity was also observed by Shiohara et al. (2004): MUA-coated CdSe/ZnS QDs were observed to be cytotoxic to HeLa cells and primary human hepatocytes at concentrations of 100 µg/mL (MTT assay).”
MethodOberdörster, G., Maynard, A., Donaldson, K., Castranova, V., Fitzpatrick, J., Ausman, K., Carter, J., Karn, B., Kreyling, W., Lai, D., et al. (2005) · Particle and Fibre Toxicology · doi:10.1186/1743-8977-2-8 · Cited by 2,134
Cytotoxicity of Colloidal CdSe and CdSe/ZnS Nanoparticles
Kirchner, C., Liedl, T., Kudera, S., Pellegrino, T., Muñoz Javier, A., Gaub, H. E., Stölzle, S., Fertig, N., & Parak, W. J. (2005) · Nano Letters · doi:10.1021/nl047996m · Cited by 1,619
Metadata
- Authors
- Shiohara, A., Hoshino, A., Hanaki, K., Suzuki, K., & Yamamoto, K.
- Affiliations
- National Institute of Infectious Diseases (JP)
- Department of Medical Ecology and Informatics, Research Institute International Medical Center of Japan Shinjuku‐ku Tokyo 162‐8655 Japan
- Corresponding author
- Yamamoto, Kenji
- Venue
- Microbiology and Immunology
- Publisher
- Wiley
- Published
- 2004-09
- Volume
- 48
- Issue
- 9
- Pages
- 669-675
- ISSN
- 0385-5600 (ISSN-L)
- 1348-0421
- OpenAlex
- W2050289957
- Semantic Scholar
- ed1ee35465dc4e717235d9a635cb06e15cacd4ce
- Cited by
- 385
- References
- 31
- Citations by year
- 2026: 4 · 2025: 2 · 2024: 9 · 2023: 12 · 2022: 6 · 2021: 10 · 2020: 14 · 2019: 10 · 2018: 12 · 2017: 17 · 2016: 15 · 2015: 22 · 2014: 21 · 2013: 18 · 2012: 28
- FWCI
- 12.49
- Type
- journal article
- Language
- en
- Open access
- closed
- Locations
- Microbiology and Immunology (publishedVersion)
- PubMed (publishedVersion)
- Topics
- Physical Sciences › Materials Science › Materials Chemistry › Quantum Dots Synthesis And Properties
- Physical Sciences › Materials Science › Materials Chemistry › Nanoparticles: synthesis and applications
- Life Sciences › Biochemistry, Genetics and Molecular Biology › Cancer Research › Photodynamic Therapy Research Studies
- Keywords
- quantum dots, cytotoxicity, CdSe quantum dots, cell viability, cell death, Vero cells, immunostaining, nanoparticle toxicity
- MeSH terms
- Animals, Cadmium, Cell Survival, Chlorocebus aethiops, Flow Cytometry, Fluorescent Dyes, HeLa Cells, Humans, Selenium, Sulfhydryl Compounds, Vero Cells, Cell Death, Hepatocytes, Quantum Dots
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review