Non‐invasive monitoring of muscle blood perfusion by photoplethysmography: evaluation of a new application
The DOI matches its Crossref record; 4 of the 4 references it cites were found in a registry or an index.
Abstract
Aim: To evaluate a specially developed photoplethysmographic (PPG) technique, using green and near‐infrared light sources, for simultaneous non‐invasive monitoring of skin and muscle perfusion. Methods: Evaluation was based on assessments of changes in blood perfusion to various provocations, such as post‐exercise hyperaemia and hyperaemia following the application of liniment. The deep penetrating feature of PPG was investigated by measurement of optical radiation inside the muscle. Simultaneous measurements using ultrasound Doppler and the new PPG application were performed to elucidate differences between the two methods. Specific problems related to the influence of skin temperature on blood flow were highlightened, as well. Results: Following static and dynamic contractions an immediate increase in muscle perfusion was shown, without increase in skin perfusion. Liniment application to the skin induced a rapid increase in skin perfusion, but not in muscle. Both similarities and differences in blood flow measured by Ultrasound Doppler and PPG were demonstrated. The radiant power measured inside the muscle, by use of an optical fibre, showed that the near‐infrared light penetrates down to the vascular depth inside the muscle. Conclusions: The results of this study indicate the potentiality of the method for non‐invasive measurement of local muscle perfusion, although some considerations still have to be accounted for, such as influence of temperature on blood perfusion.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
A review of the optical properties of biological tissues
Cheong, W. F., Prahl, S. A., & Welch, A. J. (1990) · IEEE Journal of Quantum Electronics · doi:10.1109/3.64354 · Cited by 2,530 · cited 1×
“However, the adipose is a weak absorption medium, while the muscle has strong absorption at 880 nm (Cheong et al. 1990, Graaf et al. 1993), partly because of higher blood vessel density in the muscle.”
BackgroundSkin photoplethysmography — a review
Kamal, A. A. R., Harness, J. B., Irving, G., & Mearns, A. J. (1989) · Computer Methods and Programs in Biomedicine · doi:10.1016/0169-2607(89)90159-4 · Cited by 328 · cited 1×
“Variations in the photodetector signal are related to changes in blood flow and blood volume in the underlying tissue (Challoner 1979, Kamal et al. 1989).”
BackgroundValidation of a device to measure arterial pulse wave velocity by a photoplethysmographic method
Loukogeorgakis, S., Dawson, R., Phillips, N., Martyn, C. N., & Greenwald, S. E. (2002) · Physiological Measurement · doi:10.1088/0967-3334/23/3/309 · Cited by 164 · cited 1×
“Loukogeorkakis et al. (2002) have during pulse wave velocity measurements demonstrated the ability to 2005 Scandinavian Physiological Society 341 obtain PPG signals (wavelength 880 nm) from larger arteries, such as the radial artery.”
BackgroundMuscle blood flow and oxygen uptake in recovery from exercise
BANGSBO, J., & HELLSTEN, Y. (1998) · Acta Physiologica Scandinavica · doi:10.1046/j.1365-201x.1998.0331e.x · Cited by 118 · cited 1×
“It is well known that the blood perfusion increases significantly in muscles after both static and dynamic exercise (Bangsbo & Hellsten 1998).”
Background
Cited by
Photoplethysmography and its application in clinical physiological measurement
Allen, J. (2007) · Physiological Measurement · doi:10.1088/0967-3334/28/3/r01 · Cited by 3,967
“The role of PPG wavelength in perfusion measurement has also been discussed by de Trafford and Lafferty (1984), Giltvedt et al (1984), Cui et al (1990) and Sandberg et al (2005).”
MethodMonitoring of the central blood pressure waveform via a conformal ultrasonic device
Wang, C., Li, X., Hu, H., Zhang, L., Huang, Z., Lin, M., Zhang, Z., Yin, Z., Huang, B., Gong, H., et al. (2018) · Nature Biomedical Engineering · doi:10.1038/s41551-018-0287-x · Cited by 895
The use of photoplethysmography for assessing hypertension
Elgendi, M., Fletcher, R., Liang, Y., Howard, N., Lovell, N. H., Abbott, D., Lim, K., & Ward, R. (2019) · npj Digital Medicine · doi:10.1038/s41746-019-0136-7 · Cited by 625
Flexible Wearable Sensors for Cardiovascular Health Monitoring
Chen, S., Qi, J., Fan, S., Qiao, Z., Yeo, J. C., & Lim, C. T. (2021) · Advanced Healthcare Materials · doi:10.1002/adhm.202100116 · Cited by 453
Hamaoka, T., McCully, K. K., Quaresima, V., Yamamoto, K., & Chance, B. (2007) · Journal of Biomedical Optics · doi:10.1117/1.2805437 · Cited by 329
Metadata
- Authors
- Sandberg, M., Zhang, Q., Styf, J., Gerdle, B., & Lindberg, L. ‐.
- Venue
- Acta Physiologica Scandinavica
- Publisher
- Wiley
- Published
- 2005-03-30
- Volume
- 183
- Issue
- 4
- Pages
- 335-343
- ISSN
- 0001-6772 (ISSN-L)
- 1365-201X
- OpenAlex
- W2087503506
- Cited by
- 91
- References
- 4
- FWCI
- 3.61
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.