The formulation and introduction of a ‘can't intubate, can't ventilate’ algorithm into clinical practice
Open accessThe DOI matches its Crossref record; 20 of the 20 references it cites were found in a registry or an index.
Abstract
Summary: Both the American Society of Anesthesiologists and the Difficult Airway Society of the United Kingdom have published guidelines for the management of unanticipated difficult intubation. Both algorithms end with the ‘can't intubate, can't ventilate’ scenario. This eventuality is rare within elective anaesthetic practice with an estimated incidence of 0.01–2 in 10 000 cases, making the maintenance of skills and knowledge difficult. Over the last four years, the Department of Anaesthetics at the Royal Perth Hospital have developed a didactic airway training programme to ensure staff are appropriately trained to manage difficult and emergency airways. This article discusses our training programme, the evaluation of emergency airway techniques and subsequent development of a ‘can't intubate, can't ventilate’ algorithm.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Adverse Respiratory Events in Anesthesia: A Closed Claims Analysis
Caplan, R. A., Posner, K. L., Ward, R. J., & Cheney, F. W. (1990) · Anesthesiology · doi:10.1097/00000542-199005000-00010 · Cited by 1,060
Difficult Airway Society guidelines for management of the unanticipated difficult intubation
Henderson, J. J., Popat, M. T., Latto, I. P., & Pearce, A. C. (2004) · Anaesthesia · doi:10.1111/j.1365-2044.2004.03831.x · Cited by 1,025
Ezri, T., Gewürtz, G., Sessler, D. I., Medalion, B., Szmuk, P., Hagberg, C., & Susmallian, S. (2003) · Anaesthesia · doi:10.1046/j.1365-2044.2003.03412.x · Cited by 381
What Is the Minimum Training Required for Successful Cricothyroidotomy?: A Study in Mannequins
Wong, D. T., Prabhu, A. J., Coloma, M., Imasogie, N., & Chung, F. F. (2003) · Anesthesiology · doi:10.1097/00000542-200302000-00013 · Cited by 268
Combes, X., Le Roux, B., Suen, P., Dumerat, M., Motamed, C., Sauvat, S., Duvaldestin, P., & Dhonneur, G. (2004) · Anesthesiology · doi:10.1097/00000542-200405000-00016 · Cited by 224
Parmet, J. L., Colonna-Romano, P., Horrow, J. C., Miller, F., Gonzales, J., & Rosenberg, H. (1998) · Anesthesia & Analgesia · doi:10.1097/00000539-199809000-00032 · Cited by 176
Eisenburger, P., Laczika, K. F., List, M., Wilfing, A., Losert, H., Hofbauer, R., Burgmann, H., Bankl, H. C., Pikula, B., Benumof, J. L., et al. (2000) · Anesthesiology · doi:10.1097/00000542-200003000-00012 · Cited by 148
Schaumann, N., Lorenz, V., Schellongowski, P., Staudinger, T., Locker, G. J., Burgmann, H., Pikula, B., Hofbauer, R., Schuster, E., & Frass, M. (2004) · Anesthesiology · doi:10.1097/00000542-200501000-00005 · Cited by 118
Wong, D. T., Lai, K., Chung, F. F., & Ho, R. Y. W. (2005) · Anesthesia & Analgesia · doi:10.1213/01.ane.0000148695.37190.34 · Cited by 117
Cited by
Frerk, C., Mitchell, V. S., McNarry, A. F., Mendonca, C., Bhagrath, R., Patel, A., O’Sullivan, E. P., Woodall, N. M., & Ahmad, I. (2015) · British Journal of Anaesthesia · doi:10.1093/bja/aev371 · Cited by 2,214
“alternative for anaesthetists who are experienced with this method, the evidence suggests that a surgical cricothyroidotomy is both faster and more reliable.(288)”
MethodMushambi, M. C., Kinsella, S. M., Popat, M., Swales, H., Ramaswamy, K. K., Winton, A. L., & Quinn, A. C. (2015) · Anaesthesia · doi:10.1111/anae.13260 · Cited by 608
Complications and failure of airway management
Cook, T. M., & MacDougall-Davis, S. R. (2012) · British Journal of Anaesthesia · doi:10.1093/bja/aes393 · Cited by 525
ORIGINAL ARTICLE: Accuracy of surface landmark identification for cannula cricothyroidotomy
Elliott, D. S. J., Baker, P. A., Scott, M. R., Birch, C. W., & Thompson, J. M. D. (2010) · Anaesthesia · doi:10.1111/j.1365-2044.2010.06425.x · Cited by 170
Strategies for the prevention of airway complications – a narrative review
Cook, T. M. (2018) · Anaesthesia · doi:10.1111/anae.14123 · Cited by 167
“tralasia the narrow-bore needle is generally favoured [103].”
BackgroundTranstracheal jet ventilation in the “can’t intubate can’t oxygenate” emergency: a systematic review
Duggan, L. V., Ballantyne Scott, B., Law, J. A., Morris, I. R., Murphy, M. F., & Griesdale, D. E. (2016) · British Journal of Anaesthesia · doi:10.1093/bja/aew192 · Cited by 114
Evidence is important: safety considerations for emergency catheter cricothyroidotomy
Marshall, S. D. (2016) · Academic Emergency Medicine · doi:10.1111/acem.13037 · Cited by 4
Metadata
- Authors
- Heard, A. M. B., Green, R. J., & Eakins, P.
- Venue
- Anaesthesia
- Publisher
- Wiley
- Published
- 2009-05
- Volume
- 64
- Issue
- 6
- Pages
- 601-608
- ISSN
- 0003-2409 (ISSN-L)
- 1365-2044
- OpenAlex
- W2171854009
- Cited by
- 182
- References
- 20
- FWCI
- 13.80
- Type
- journal article
- Language
- en
- Open access
- bronze
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.