Equipment and strategies for emergency tracheal access in the adult patient
The DOI matches its Crossref record; 1 of the 1 references it cites were found in a registry or an index.
Abstract
Summary: The inability to maintain oxygenation by non‐invasive means is one of the most pressing emergencies in anaesthesia and emergency care. To prevent hypoxic brain damage and death in a ‘cannot intubate, cannot oxygenate’ situation, emergency percutaneous airway access must be performed immediately. Even though this emergency is rare, every anaesthetist should be capable of performing an emergency percutaneous airway as the situation may arise unexpectedly. Clear knowledge of the anatomy and the insertion technique, and repeated skill training are essential to ensure completion of this procedure rapidly and successfully. Various techniques have been described for emergency oxygenation and several commercial emergency cricothyroidotomy sets are available. There is, however, no consensus on the best technique or device. As each has its limitations, it is recommended that all anaesthetists are skilled in more than one technique of emergency percutaneous airway. Avoiding delay in initiating rescue techniques is at least as important as choice of device in determining outcome.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Cook, T. M., Woodall, N., & Frerk, C. (2011) · British Journal of Anaesthesia · doi:10.1093/bja/aer058 · Cited by 2,415
Cited by
Frerk, C., Mitchell, V. S., McNarry, A. F., Mendonca, C., Bhagrath, R., Patel, A., O’Sullivan, E. P., Woodall, N. M., & Ahmad, I. (2015) · British Journal of Anaesthesia · doi:10.1093/bja/aev371 · Cited by 2,214
Complications and failure of airway management
Cook, T. M., & MacDougall-Davis, S. R. (2012) · British Journal of Anaesthesia · doi:10.1093/bja/aes393 · Cited by 525
for the Canadian Airway Focus Group, Law, J. A., Broemling, N., Cooper, R. M., Drolet, P., Duggan, L. V., Griesdale, D. E., Hung, O. R., Jones, P. M., Kovacs, G., et al. (2013) · Canadian Journal of Anesthesia/Journal canadien d'anesthésie · doi:10.1007/s12630-013-0019-3 · Cited by 358
Myatra, S. N., Shah, A., Kundra, P., Patwa, A., Ramkumar, V., Divatia, J. V., Raveendra, U. S., Shetty, S. R., Ahmed, S. M., Doctor, J. R., et al. (2016) · Indian Journal of Anaesthesia · doi:10.4103/0019-5049.195481 · Cited by 294
Kovacs, G., & Sowers, N. (2018) · Emergency Medicine Clinics of North America · doi:10.1016/j.emc.2017.08.006 · Cited by 115
“It is widely speculated that the most significant delay is often the result of hesitant decision-making and a reluctance to perform a rarely encountered procedure.(112) Open discussion of the emergency surgical airway as a potential outcome familiarizes the teamand normalizes the procedure, shifting from the negative…”
Background
Metadata
- Authors
- Hamaekers, A. E., & Henderson, J. J.
- Venue
- Anaesthesia
- Publisher
- Wiley
- Published
- 2011-11-10
- Volume
- 66
- Issue
- s2
- Pages
- 65-80
- ISSN
- 0003-2409 (ISSN-L)
- 1365-2044
- OpenAlex
- W1550349588
- Cited by
- 98
- References
- 1
- FWCI
- 7.72
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.