Collecting factors related to the haemolysis of blood specimens
Open accessThe DOI matches its Crossref record.
Abstract
Aim. The purpose of the study is to explore the collecting factors for the haemolysis of the blood specimens in a regional hospital in South Taiwan. Background. Blood collecting is one of the most common procedures used in hospital. However, it often faces the risk of haemolysis of blood specimens during laboratory testing and the specimens collected can be easily rejected by the laboratory. Methods. This is a descriptive and cross‐sectional study. The purposive samples were collected from the blood specimens of the hospitalized patients or the emergency‐room patients by using structured observational checklists which included demographic characteristics, caring factors and material factors. A total of 274 blood specimens was collected. Results. Specimens obtained from non‐antecubital sites were 3·35 times at risk of haemolysis as many as those from antecubital sites (p = 0·001). Blood collected into tubes through steel needles were 3·7 times more at risk of haemolysis as that through syringes (after removing needles) (p = 0·002). Specimens delivered by ward assistants were 8·7 times more at risk for haemolysis as those by the laboratory staff (p < 0·01). Conclusions. These findings suggest that nurse supervisors establish a protocol related to preventing haemolysis. Future research should explore the effectiveness of this protocol to verify the relationship between different gauges of steel needles or catheters and haemolysis. Relevance to clinical practice. Nurse educators are encouraged to include the factors affecting and preventing haemolysis into the in service education. Therefore, findings may assist healthcare professionals in minimizing the risk of haemolysis and improve the quality of care.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cited by
Haemolysis: an overview of the leading cause of unsuitable specimens in clinical laboratories
Lippi, G., Blanckaert, N., Bonini, P., Green, S., Kitchen, S., Palicka, V., Vassault, A. J., & Plebani, M. (2008) · Clinical Chemistry and Laboratory Medicine · doi:10.1515/cclm.2008.170 · Cited by 466
ACVIM consensus statement on the diagnosis of immune-mediated hemolytic anemia in dogs and cats
Garden, O. A., Kidd, L., Mexas, A. M., Chang, Y.-M., Jeffery, U., Blois, S. L., Fogle, J. E., MacNeill, A. L., Lubas, G., Birkenheuer, A., et al. (2019) · Journal of Veterinary Internal Medicine · doi:10.1111/jvim.15441 · Cited by 214
“Common causes of in vitro hemolysis include, but are not limited to, traumatic venipuncture, freezing, storage, and (based on studies in humans) sampling via an IV catheter(72,76,77) or post-collection injection of samples into vacutainers.(78) The likelihood of in vitro hemolysis is increased if factors that increase…”
Simundic, A.-M., Cornes, M., Grankvist, K., Lippi, G., Nybo, M., Kovalevskaya, S., Sprongl, L., Sumarac, Z., & Church, S. (2013) · Clinical Chemistry and Laboratory Medicine (CCLM) · doi:10.1515/cclm-2013-0283 · Cited by 84
Lippi, G., Cervellin, G., & Mattiuzzi, C. (2013) · Biochemia Medica · doi:10.11613/bm.2013.022 · Cited by 66
“Overall, 15 articles were fi nally selected for inclusion in meta-analysis (14-28).”
BackgroundBölenius, K., Lindkvist, M., Brulin, C., Grankvist, K., Nilsson, K., & Söderberg, J. (2013) · BMC Health Services Research · doi:10.1186/1472-6963-13-463 · Cited by 30
“Test tubes are at higher risk of haemolysis if reversed more than 12 times [1,11].”
BackgroundInfluential
Metadata
- Authors
- Fang, L., Fang, S., Chung, Y., & Chien, S.
- Venue
- Journal of Clinical Nursing
- Publisher
- Wiley
- Published
- 2008-08-13
- Volume
- 17
- Issue
- 17
- Pages
- 2343-2351
- ISSN
- 0962-1067 (ISSN-L)
- 1365-2702
- OpenAlex
- W2082474284
- Cited by
- 37
- References
- 0
- FWCI
- 1.01
- Type
- journal article
- Language
- en
- Open access
- bronze
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Collecting factors related to the haemolysis of blood specimens. https://app.cochat.ai/papers/10.1111/j.1365-2702.2006.02057.x
- The paper
- Fang, L., Fang, S., Chung, Y., & Chien, S. (2008). Collecting factors related to the haemolysis of blood specimens. Journal of Clinical Nursing. https://doi.org/10.1111/j.1365-2702.2006.02057.x
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.