HIGH PERFORMANCE LIQUID CHROMATOGRAPHIC ANALYSIS OF CAFFEINE CONCENTRATIONS IN PLASMA AND SALIVA
The DOI matches its Crossref record.
Abstract
A rapid high performance liquid chromatographic (HPLC) method for the analysis of caffeine in plasma and saliva is described. Samples of saliva and plasma were purified using zinc sulphate solution as protein precipitant. The supernatant was injected directly onto the column. The mobile phase consisted of ammonium acetate buffer:acetonitrile:methanol (82:15:3, v/v). Measurements were carried out at 254 nm. Acetanilide was used as the internal standard and analysis was completed in 10 min. No interference from endogenous components or other methylxanthines was observed. The coefficients of variation for within day and between day analysis for both saliva and plasma were less than 7.66%. Samples were collected from 20 volunteers. The correlation coefficient between plasma and saliva caffeine concentrations was found to be 0.98.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cited by
Lieberman, H., Tharion, W., Shukitt-Hale, B., Speckman, K., & Tulley, R. (2002) · Psychopharmacology · doi:10.1007/s00213-002-1217-9 · Cited by 576
Acute and chronic effects of caffeine on performance, mood, headache, and sleep
James, J. E. (1998) · Neuropsychobiology · doi:10.1159/000026514 · Cited by 157
Effects of caffeine on daytime recovery sleep: A double challenge to the sleep–wake cycle in aging
Carrier, J., Paquet, J., Fernandez-Bolanos, M., Girouard, L., Roy, J., Selmaoui, B., & Filipini, D. (2009) · Sleep Medicine · doi:10.1016/j.sleep.2009.01.001 · Cited by 82
“A rapid high performance liquid chromatography (HPLC) method was used for the salivary caffeine analysis [25].”
MethodChronic Effects of Habitual Caffeine Consumption on Laboratory and Ambulatory Blood Pressure Levels
James, J. E. (1994) · European Journal of Cardiovascular Prevention & Rehabilitation · doi:10.1177/174182679400100210 · Cited by 53
Sleep is more sensitive to high doses of caffeine in the middle years of life
Robillard, R., Bouchard, M., Cartier, A., Nicolau, L., & Carrier, J. (2015) · Journal of Psychopharmacology · doi:10.1177/0269881115575535 · Cited by 53
“A rapid high-performance liquid chromatographic (HPLC) method (Alkaysi et al., 1988) was used for the analysis of caffeine in saliva.”
Method
Metadata
- Authors
- Alkaysi, H. N., Salem, M. S., & El-Sayed, Y. M.
- Venue
- Journal of Clinical Pharmacy and Therapeutics
- Publisher
- Hindawi Limited
- Published
- 1988-04
- Volume
- 13
- Issue
- 2
- Pages
- 109-115
- ISSN
- 0269-4727 (ISSN-L)
- 1365-2710
- OpenAlex
- W1987719727
- Cited by
- 29
- References
- 0
- FWCI
- 0.38
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: HIGH PERFORMANCE LIQUID CHROMATOGRAPHIC ANALYSIS OF CAFFEINE CONCENTRATIONS IN PLASMA AND SALIVA. https://app.cochat.ai/papers/10.1111/j.1365-2710.1988.tb00165.x
- The paper
- Alkaysi, H. N., Salem, M. S., & El-Sayed, Y. M. (1988). HIGH PERFORMANCE LIQUID CHROMATOGRAPHIC ANALYSIS OF CAFFEINE CONCENTRATIONS IN PLASMA AND SALIVA. Journal of Clinical Pharmacy and Therapeutics. https://doi.org/10.1111/j.1365-2710.1988.tb00165.x
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.