CoChat

Thickness variations within individual paraffin and glycol methacrylate sections

Helander, K. G. · 1983 · Journal of Microscopy
Cited by 64

The DOI matches its Crossref record.

Abstract

SUMMARY: The object of this study was to investigate whether there are intra‐section thickness variations in individual paraffin and glycol methacrylate (GMA) sections. Using steel or glass knives sections were cut from liver and urinary bladder. Section thickness variations were measured with an interference microscope and amounted to 1–3 μm within individual paraffin sections and 0.3 μm within GMA sections. The results were confirmed by observations on sections which had been re‐embedded and re‐sectioned. Some of the variations within the paraffin sections were associated with the cell nuclei. It is concluded that GMA sections are much smoother than paraffin sections and thus more suitable for quantitative histological studies.

Overview

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1111/j.1365-2818.1983.tb04276.x

Cites

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Metadata

Authors
Helander, K. G.
Venue
Journal of Microscopy
Publisher
Wiley
Published
1983-11
Volume
132
Issue
2
Pages
223-227
ISSN
  • 0022-2720 (ISSN-L)
  • 1365-2818
OpenAlex
W1972934681
Cited by
64
References
0
FWCI
4.78
Type
journal article
Language
en
Open access
closed

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

How to cite

Cite CoChat for the checks on this page, and the paper for its own findings.

This page
CoChat. (2026). Citation check: Thickness variations within individual paraffin and glycol methacrylate sections. https://app.cochat.ai/papers/10.1111/j.1365-2818.1983.tb04276.x
The paper
Helander, K. G. (1983). Thickness variations within individual paraffin and glycol methacrylate sections. Journal of Microscopy. https://doi.org/10.1111/j.1365-2818.1983.tb04276.x

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.