Moving EM: the Rapid Transfer System as a new tool for correlative light and electron microscopy and high throughput for high‐pressure freezing
The DOI matches its Crossref record; 26 of the 26 references it cites were found in a registry or an index.
Abstract
Summary: In this paper, the Rapid Transfer System (RTS), an attachment to the Leica EMPACT2 high‐pressure freezer, is described as a new tool for special applications within the cryofixation field. The RTS is an automated system that allows for fast processing of samples (<5 s) that make it possible for the first time to use high‐pressure freezing in combination with high time resolution correlative light and electron microscopy. In addition, with a working cycle of 30 s this rapid turn over time allows one to acquire more samples of biopsy material before it deteriorates than with other HPF machines with longer cycle times. With the use of the RTS it was possible to obtain three samples each of four different tissues in 6 min. Together with the finding that 90% of samples of cells grown on sapphire discs were well frozen, the RTS was both fast and reliable. Most important, together with other newly developed accessories, the RTS made it possible to capture specific events occurring live in the cell as observed by light microscopy, to cryofix that sample/event within 4 s, and then to analyze that event at high resolution in the electron microscope with excellent preservation of ultra‐structure. These developments should give us the tools to unravel intracellular processes that can be observed by live cell imaging but are too rare or fast to be picked up by routine EM methods or where the history of a structure is necessary to be able to discern its nature.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Multicolor and Electron Microscopic Imaging of Connexin Trafficking
Gaietta, G., Deerinck, T. J., Adams, S. R., Bouwer, J., Tour, O., Laird, D. W., Sosinsky, G. E., Tsien, R. Y., & Ellisman, M. H. (2002) · Science · doi:10.1126/science.1068793 · Cited by 907 · cited 3×
“Examples of these are the ReAsh compound (Gaietta et al., 2002) and quantum dots (Giepmans et al., 2005).”
BackgroundAPPL Proteins Link Rab5 to Nuclear Signal Transduction via an Endosomal Compartment
Miaczynska, M., Christoforidis, S., Giner, A., Shevchenko, A., Uttenweiler-Joseph, S., Habermann, B., Wilm, M., Parton, R. G., & Zerial, M. (2004) · Cell · doi:10.1016/s0092-8674(04)00117-5 · Cited by 539 · cited 1×
“The internalization and trafficking of these EGF-markers happens in the same way as EGF coupled to a fluorescent marker alone (a marker that is generally used for studies involving EGF internalization (Miaczynska et al., 2004), data not shown).”
BackgroundCryo‐electron microscopy of vitreous sections
Al‐Amoudi, A., Chang, J., Leforestier, A., McDowall, A., Salamin, L. M., Norlén, L. P., Richter, K., Blanc, N. S., Studer, D., & Dubochet, J. (2004) · The EMBO Journal · doi:10.1038/sj.emboj.7600366 · Cited by 456
Theory and Practice of High Pressure Freezing
Moor, H. (1987) · Cryotechniques in Biological Electron Microscopy · doi:10.1007/978-3-642-72815-0_8 · Cited by 448 · cited 6×
“That loading the sample is a crucial step was already realized by C© 2008 The Author Journal compilation C© 2008 The Royal Microscopical Society, Journal of Microscopy, 230, 317–328 the ‘founding father’ of HPF Hans Moor (Moor, 1987).”
BackgroundInfluentialFelder, S., Miller, K., Moehren, G., Ullrich, A., Schlessinger, J., & Hopkins, C. R. (1990) · Cell · doi:10.1016/0092-8674(90)90474-s · Cited by 445 · cited 4×
“The MVB in the example is seen as a translucent structure, since the content is not visualized well (mainly fluid, little protein or lipid).”
BackgroundInfluentialCorrelated light and electron microscopic imaging of multiple endogenous proteins using Quantum dots
Giepmans, B. N. G., Deerinck, T. J., Smarr, B. L., Jones, Y. Z., & Ellisman, M. H. (2005) · Nature Methods · doi:10.1038/nmeth791 · Cited by 388 · cited 3×
“Examples of these are the ReAsh compound (Gaietta et al., 2002) and quantum dots (Giepmans et al., 2005).”
BackgroundHigh pressure freezing comes of age.
Studer, D., Michel, M., & Müller, M. (1989) · PubMed · Cited by 360
Walther, P., & Ziegler, A. (2002) · Journal of Microscopy · doi:10.1046/j.1365-2818.2002.01064.x · Cited by 292 · cited 2×
“Thus, the effect would be the same as observed by Walther and Ziegler (2002).”
BackgroundA new approach for cryofixation by high‐pressure freezing
Studer, D., Graber, W., Al‐Amoudi, A., & Eggli, P. (2001) · Journal of Microscopy · doi:10.1046/j.1365-2818.2001.00919.x · Cited by 286 · cited 6×
“As the basic principle of the EM PACT2 is the same as for the EM PACT, the reader is referred to the paper of Studer (Studer et al., 2001) for further technical details.”
BackgroundMethodResultInfluentialRapid and effective labeling of brain tissue using TAT-conjugated CdS∶Mn/ZnS quantum dots
Santra, S., Yang, H., Stanley, J. T., Holloway, P. H., Moudgil, B. M., Walter, G., & Mericle, R. A. (2005) · Chemical Communications · doi:10.1039/b503234b · Cited by 215 · cited 1×
“People have succeeded in constructing quantum dots that are able to cross the plasma membrane (Santra et al., 2005).”
BackgroundCorrelative microscopy and electron tomography of GFP through photooxidation
Grabenbauer, M., Geerts, W. J. C., Fernadez-Rodriguez, J., Hoenger, A., Koster, A. J., & Nilsson, T. (2005) · Nature Methods · doi:10.1038/nmeth806 · Cited by 211 · cited 2×
“These new pre-embedding techniques made use of DAB precipitation by antibody labelling (Mironov et al., 2000) or photo conversion (Grabenbauer et al., 2005).”
MethodMurk, J. L. A. N., Posthuma, G., Koster, A. J., Geuze, H. J., Verkleij, A. J., Kleijmeer, M. J., & Humbel, B. M. (2003) · Journal of Microscopy · doi:10.1046/j.1365-2818.2003.01238.x · Cited by 198 · cited 1×
“The advantage of being able to study processes at higher resolution is then sometimes lost by compromising the ultrastructure (see e.g. Murk et al., 2003).”
BackgroundMcDonald, K. (2003) · Electron Microscopy Methods and Protocols · doi:10.1385/1-59259-201-5:77 · Cited by 169 · cited 3×
“Of all cryo-fixation methods, HPF is the one most suited for freezing thicker samples (generally 200–300 μm, Müller & Moor, 1984; Dahl & Staehelin, 1989; McDonald, 1999; McDonald et al., 2007).”
BackgroundMethodRecent Advances in High-Pressure Freezing
McDonald, K. L., Morphew, M. K., Verkade, P., & Müller‐Reichert, T. (2007) · Methods in molecular biology · doi:10.1007/978-1-59745-294-6_8 · Cited by 151 · cited 9×
“2B), new membrane carriers (McDonald et al., 2007; Fig.”
BackgroundMethodInfluentialSelf-citationThe Science of Biological Specimen Preparation for Microscopy and Microanalysis
Toner, P. G. (1985) · Journal of Clinical Pathology · doi:10.1136/jcp.38.6.717-d · Cited by 140 · cited 2×
“Since the first developments of cryofixation via HPF by Riehle, Moor, Müller and others (see, e.g. Moor & Riehle, 1968; Riehle, 1968; Müller & Moor, 1984; Dahl & Staehelin, 1989; Studer et al., 1989) a lot of progress has been made with the result that three companies are now selling HPF machines.”
BackgroundMethodGiddings, T. H. (2003) · Journal of Microscopy · doi:10.1046/j.1365-2818.2003.01228.x · Cited by 127 · cited 1×
“There have been several attempts to improve the visualization of membranes during freeze substitution, for example by addition of water or combining glutaraldehyde and osmium in the freeze substitution medium (Wild et al., 2001; Walther & Ziegler, 2002; see also Giddings, 2003).”
BackgroundCorrelative Light and Electron Microscopy of Early Caenorhabditis elegans Embryos in Mitosis
Müller‐Reichert, T., Srayko, M., Hyman, A. A., O'Toole, E. T., & McDonald, K. L. (2007) · Methods in cell biology · doi:10.1016/s0091-679x(06)79004-5 · Cited by 111 · cited 1×
“Recently people have also used GFP as the marker for the visualization at the LM and use this to retrace specific cells and areas within a cell (McDonald et al., 2007; Müller-Reichert et al., 2007; Sims & Hardin, 2007).”
MethodRapid freeze‐substitution preserves membranes in high‐pressure frozen tissue culture cells
Hawes, P. C., Netherton, C. L., Mueller, M. G., Wileman, T. E., & MONAGHAN, P. (2007) · Journal of Microscopy · doi:10.1111/j.1365-2818.2007.01767.x · Cited by 106 · cited 2×
“Hawes et al. (2007) recently reported a similar short freeze substitution protocol.”
BackgroundHigh‐pressure freezing of tissue obtained by fine‐needle biopsy
Hohenberg, H., Tobler, M., & MÜLLER, M. (1996) · Journal of Microscopy · doi:10.1046/j.1365-2818.1996.820642.x · Cited by 62 · cited 2×
“The abdomen was opened and biopsies were taken with a biopsy gun (Hohenberg et al., 1996; Vanhecke et al., 2003, Leica Microsystems).”
MethodVisualizing membrane traffic in vivo by combined video fluorescence and 3D electron microscopy
Aa, M., Polishchuk, R., & Luini, A. (2000) · Trends in Cell Biology · doi:10.1016/s0962-8924(00)01787-6 · Cited by 62 · cited 3×
“These new pre-embedding techniques made use of DAB precipitation by antibody labelling (Mironov et al., 2000) or photo conversion (Grabenbauer et al., 2005).”
MethodEnhanced resolution of membranes in cultured cells by cryoimmobilization and freeze‐substitution
Wild, P., Schraner, E. M., Adler, H., & Humbel, B. M. (2001) · Microscopy Research and Technique · doi:10.1002/jemt.1098 · Cited by 59 · cited 1×
“There have been several attempts to improve the visualization of membranes during freeze substitution, for example by addition of water or combining glutaraldehyde and osmium in the freeze substitution medium (Wild et al., 2001; Walther & Ziegler, 2002; see also Giddings, 2003).”
BackgroundCaveolin-1 Is Not Essential for Biosynthetic Apical Membrane Transport
Manninen, A., Verkade, P., Lay, S. L., Torkko, J. M., Kasper, M. E., Füllekrug, J., & Simons, K. (2005) · Molecular and Cellular Biology · doi:10.1128/mcb.25.22.10087-10096.2005 · Cited by 52 · cited 2×
“The very first publication on the EM PACT 2 + RTS (Manninen et al., 2005) used this property for statistical analysis of the number of caveolae in filter-grown MDCK cells.”
BackgroundMethodSelf-citationCorrelative microscopy in biology—Instrumentation and methods
(1989) · Journal of Steroid Biochemistry · doi:10.1016/0022-4731(89)90316-6 · Cited by 40
Fluorescence-Integrated Transmission Electron Microscopy Images
Sims, P. A., & Hardin, J. D. (2007) · Methods in molecular biology · doi:10.1007/978-1-59745-294-6_14 · Cited by 37 · cited 4×
“As with the data of Sims and Hardin (2007), it may be a compromise between retention of ultrastructure and immunoreactivity.”
BackgroundMethodInfluentialVanhecke, D., Graber, W. A., Herrmann, G., Al‐Amoudi, A., Eggli, P., & Studer, D. (2003) · Journal of Microscopy · doi:10.1046/j.1365-2818.2003.01226.x · Cited by 35 · cited 3×
“The abdomen was opened and biopsies were taken with a biopsy gun (Hohenberg et al., 1996; Vanhecke et al., 2003, Leica Microsystems).”
BackgroundMethodSub-Second Cellular Dynamics: Time-Resolved Electron Microscopy and Functional Correlation
Plattner, H., & Hentschel, J. (2006) · International review of cytology · doi:10.1016/s0074-7696(06)55003-x · Cited by 24 · cited 2×
“These events can then be analyzed in the EM in a correlative Biochemistry and EM approach (Plattner & Hentschel, 2006).”
Background
Cited by
Correlated fluorescence and 3D electron microscopy with high sensitivity and spatial precision
Kukulski, W., Schorb, M., Welsch, S., Picco, A., Kaksonen, M., & Briggs, J. A. G. (2011) · Journal of Cell Biology · doi:10.1083/jcb.201009037 · Cited by 467
Studer, D., Humbel, B. M., & Chiquet, M. (2008) · Histochemistry and Cell Biology · doi:10.1007/s00418-008-0500-1 · Cited by 286
Townley, A. K., Feng, Y., Schmidt, K., Carter, D. A., Porter, R., Verkade, P., & Stephens, D. J. (2008) · Journal of Cell Science · doi:10.1242/jcs.031070 · Cited by 174
“Jekyll is caused by a mutation in UDP-glucose dehydrogenase that results in defective proteoglycan secretion (Walsh and Stainier, 2001).”
BackgroundSelf-citationIntegrated fluorescence and transmission electron microscopy
Agronskaia, A. V., Valentijn, J. A., van Driel, L. F., Schneijdenberg, C. T. W. M., Humbel, B. M., van Bergen en Henegouwen, P. M. P., Verkleij, A. J., Koster, A. J., & Gerritsen, H. C. (2008) · Journal of Structural Biology · doi:10.1016/j.jsb.2008.07.003 · Cited by 168
“This limitation has motivated researchers to embark on the development of imaging methods that combine FM and EM—correlative microscopy (Powell et al., 1997; Takizawa et al., 1998; Mironov et al., 2000; Polishchuk et al., 2000; Gaietta et al., 2002; Sartori et al., 2007; Verkade, 2008).”
MethodImaging three-dimensional tissue architectures by focused ion beam scanning electron microscopy
Bushby, A. J., P'ng, K. M. Y., Young, R. D., Pinali, C., Knupp, C., & Quantock, A. J. (2011) · Nature Protocols · doi:10.1038/nprot.2011.332 · Cited by 160
“Innovative methods for correlative microscopy combining these two modalities have also been develope”
Method
Metadata
- Authors
- VERKADE, P.
- Venue
- Journal of Microscopy
- Publisher
- Wiley
- Published
- 2008-04-25
- Volume
- 230
- Issue
- 2
- Pages
- 317-328
- ISSN
- 0022-2720 (ISSN-L)
- 1365-2818
- OpenAlex
- W2019541950
- Cited by
- 165
- References
- 26
- FWCI
- 8.78
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.