Student or educator? Sign up with your school email and get 6 months of Pro free.
Cited by 219

The DOI matches its Crossref record; 4 of the 4 references it cites were found in a registry or an index.

Real‐time computation of subdiffraction‐resolution fluorescence images

WOLTER, S., SCHÜTTPELZ, M., TSCHEREPANOW, M., VAN DE LINDE, S., HEILEMANN, M., SAUER, M.·2010·Journal of Microscopy

Abstract

Summary: In the recent past, single‐molecule based localization or photoswitching microscopy methods such as stochastic optical reconstruction microscopy (STORM) or photoactivated localization microscopy (PALM) have been successfully implemented for subdiffraction‐resolution fluorescence imaging. However, the computational effort needed to localize numerous fluorophores is tremendous, causing long data processing times and thereby limiting the applicability of the technique. Here we present a new computational scheme for data processing consisting of noise reduction, detection of likely fluorophore positions, high‐precision fluorophore localization and subsequent visualization of found fluorophore positions in a super‐resolution image. We present and benchmark different algorithms for noise reduction and demonstrate the use of non‐maximum suppression to quickly find likely fluorophore positions in high depth and very noisy images. The algorithm is evaluated and compared in terms of speed, accuracy and robustness by means of simulated data. On real biological samples, we find that real‐time data processing is possible and that super‐resolution imaging with organic fluorophores of cellular structures with ∼20 nm optical resolution can be completed in less than 10 s.

Overview

The claims and statistics of this paper haven’t been checked yet.

Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1111/j.1365-2818.2009.03287.x

Cites

4 of 4 references verified0 citation errors · 0 not checkable

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cites

Show all 4 references

Cited by

See all 219

Metadata

Authors
WOLTER, S., SCHÜTTPELZ, M., TSCHEREPANOW, M., VAN DE LINDE, S., HEILEMANN, M., & SAUER, M.
Venue
Journal of Microscopy
Publisher
Wiley
Published
2009-12-10
Volume
237
Issue
1
Pages
12-22
ISSN
  • 0022-2720 (ISSN-L)
  • 1365-2818
OpenAlex
W1480262878
Cited by
219
References
4
FWCI
10.31
Type
journal article
Language
en
Open access
closed

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

How to cite

Cite CoChat for the checks on this page, and the paper for its own findings.

This page
CoChat. (2026). Citation check: Real‐time computation of subdiffraction‐resolution fluorescence images. https://app.cochat.ai/papers/10.1111/j.1365-2818.2009.03287.x
The paper
WOLTER, S., SCHÜTTPELZ, M., TSCHEREPANOW, M., VAN DE LINDE, S., HEILEMANN, M., & SAUER, M. (2010). Real‐time computation of subdiffraction‐resolution fluorescence images. Journal of Microscopy. https://doi.org/10.1111/j.1365-2818.2009.03287.x

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.