Real‐time computation of subdiffraction‐resolution fluorescence images
The DOI matches its Crossref record; 6 of the 6 references it cites were found in a registry or an index.
Abstract
Summary: In the recent past, single‐molecule based localization or photoswitching microscopy methods such as stochastic optical reconstruction microscopy (STORM) or photoactivated localization microscopy (PALM) have been successfully implemented for subdiffraction‐resolution fluorescence imaging. However, the computational effort needed to localize numerous fluorophores is tremendous, causing long data processing times and thereby limiting the applicability of the technique. Here we present a new computational scheme for data processing consisting of noise reduction, detection of likely fluorophore positions, high‐precision fluorophore localization and subsequent visualization of found fluorophore positions in a super‐resolution image. We present and benchmark different algorithms for noise reduction and demonstrate the use of non‐maximum suppression to quickly find likely fluorophore positions in high depth and very noisy images. The algorithm is evaluated and compared in terms of speed, accuracy and robustness by means of simulated data. On real biological samples, we find that real‐time data processing is possible and that super‐resolution imaging with organic fluorophores of cellular structures with ∼20 nm optical resolution can be completed in less than 10 s.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
A Simplex Method for Function Minimization
Nelder, J. A., & Mead, R. (1965) · The Computer Journal · doi:10.1093/comjnl/7.4.308 · Cited by 28,905
Textural Features for Image Classification
Haralick, R. M., Shanmugam, K., & Dinstein, I. (1973) · IEEE Transactions on Systems, Man, and Cybernetics · doi:10.1109/tsmc.1973.4309314 · Cited by 22,886
Numerical recipes in C: the art of scientific computing
(1993) · Choice Reviews Online · doi:10.5860/choice.30-5638 · Cited by 17,933
Hell, S. W. (2007) · Science · doi:10.1126/science.1137395 · Cited by 2,967 · cited 2×
“This can be realized either using phase masks or interference patterns that prevent fluorescence emission in specific parts of the laser focus (Hell & Stelzer, 1992; Gustafsson,2005;Hell,2007;Dedecker et al. ,2007) or single-molecule based stochastic photoswitching of fluorophores to isolatefluorescenceemissionofindiv…”
BackgroundPrecise Nanometer Localization Analysis for Individual Fluorescent Probes
Thompson, R. E., Larson, D. R., & Webb, W. W. (2002) · Biophysical Journal · doi:10.1016/s0006-3495(02)75618-x · Cited by 2,320 · cited 3×
“Error rates in the detection process were measured by pairing, for each image, the active fluorophores [fluorophores were counted as active when emitting at least 30 photons, the transition point for photon-counting noise found by Thompson et al. (2002)] and the fluorophore localizations.”
BackgroundMethodEfficient Non-Maximum Suppression
Neubeck, A., & Van Gool, L. (2006) · 18th International Conference on Pattern Recognition (ICPR'06) · doi:10.1109/icpr.2006.479 · Cited by 2,118
Cited by
Ovesný, M., Křížek, P., Borkovec, J., Švindrych, Z., & Hagen, G. M. (2014) · Bioinformatics · doi:10.1093/bioinformatics/btu202 · Cited by 1,506
Direct stochastic optical reconstruction microscopy with standard fluorescent probes
van de Linde, S., Löschberger, A., Klein, T., Heidbreder, M., Wolter, S., Heilemann, M., & Sauer, M. (2011) · Nature Protocols · doi:10.1038/nprot.2011.336 · Cited by 1,071
Self-citationFast, single-molecule localization that achieves theoretically minimum uncertainty
Smith, C. S., Joseph, N., Rieger, B., & Lidke, K. A. (2010) · Nature Methods · doi:10.1038/nmeth.1449 · Cited by 522
Full length RTN3 regulates turnover of tubular endoplasmic reticulum via selective autophagy
Grumati, P., Morozzi, G., Hölper, S., Mari, M., Harwardt, M.-L. I., Yan, R., Müller, S., Reggiori, F., Heilemann, M., & Dikic, I. (2017) · eLife · doi:10.7554/elife.25555 · Cited by 442
Self-citationDAOSTORM: an algorithm for high- density super-resolution microscopy
Holden, S. J., Uphoff, S., & Kapanidis, A. N. (2011) · Nature Methods · doi:10.1038/nmeth0411-279 · Cited by 440
QuickPALM: 3D real-time photoactivation nanoscopy image processing in ImageJ
Henriques, R., Lelek, M., Fornasiero, E. F., Valtorta, F., Zimmer, C., & Mhlanga, M. M. (2010) · Nature Methods · doi:10.1038/nmeth0510-339 · Cited by 411
Sanderson, M. J., Smith, I., Parker, I., & Bootman, M. D. (2014) · Cold Spring Harbor Protocols · doi:10.1101/pdb.top071795 · Cited by 356
Fluorophore localization algorithms for super-resolution microscopy
Small, A., & Stahlheber, S. (2014) · Nature Methods · doi:10.1038/nmeth.2844 · Cited by 349
Live-cell super-resolution imaging with trimethoprim conjugates
Wombacher, R., Heidbreder, M., van de Linde, S., Sheetz, M. P., Heilemann, M., Cornish, V. W., & Sauer, M. (2010) · Nature Methods · doi:10.1038/nmeth.1489 · Cited by 337
Self-citationLöschberger, A., van de Linde, S., Dabauvalle, M.-C., Rieger, B., Heilemann, M., Krohne, G., & Sauer, M. (2012) · Journal of Cell Science · doi:10.1242/jcs.098822 · Cited by 306
Self-citation3‐D PSF fitting for fluorescence microscopy: implementation and localization application
KIRSHNER, H., AGUET, F., SAGE, D., & UNSER, M. (2013) · Journal of Microscopy · doi:10.1111/j.1365-2818.2012.03675.x · Cited by 277
Live-Cell Super-Resolution Imaging with Synthetic Fluorophores
van de Linde, S., Heilemann, M., & Sauer, M. (2012) · Annual Review of Physical Chemistry · doi:10.1146/annurev-physchem-032811-112012 · Cited by 266
Self-citationEndesfelder, U., Malkusch, S., Fricke, F., & Heilemann, M. (2014) · Histochemistry and Cell Biology · doi:10.1007/s00418-014-1192-3 · Cited by 259
Self-citationWhelan, D. R., & Bell, T. D. M. (2015) · Scientific Reports · doi:10.1038/srep07924 · Cited by 202
Multiscale Spatial Organization of RNA Polymerase in Escherichia coli
Endesfelder, U., Finan, K., Holden, S. J., Cook, P. R., Kapanidis, A. N., & Heilemann, M. (2013) · Biophysical Journal · doi:10.1016/j.bpj.2013.05.048 · Cited by 177
Self-citationOptical Super-Resolution Imaging of Surface Reactions
Chen, T., Dong, B., Chen, K., Zhao, F., Cheng, X., Ma, C., Lee, S., Zhang, P., Kang, S. H., Ha, J. W., et al. (2017) · Chemical Reviews · doi:10.1021/acs.chemrev.6b00673 · Cited by 168
Izeddin, I., El Beheiry, M., Andilla, J., Ciepielewski, D., Darzacq, X., & Dahan, M. (2012) · Optics Express · doi:10.1364/oe.20.004957 · Cited by 167
High abundance of BDNF within glutamatergic presynapses of cultured hippocampal neurons
Andreska, T., Aufmkolk, S., Sauer, M., & Blum, R. (2014) · Frontiers in Cellular Neuroscience · doi:10.3389/fncel.2014.00107 · Cited by 100
Self-citation
Metadata
- Authors
- WOLTER, S., SCHÜTTPELZ, M., TSCHEREPANOW, M., VAN DE LINDE, S., HEILEMANN, M., & SAUER, M.
- Venue
- Journal of Microscopy
- Publisher
- Wiley
- Published
- 2009-12-10
- Volume
- 237
- Issue
- 1
- Pages
- 12-22
- ISSN
- 0022-2720 (ISSN-L)
- 1365-2818
- OpenAlex
- W1480262878
- Cited by
- 219
- References
- 6
- FWCI
- 10.31
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.